Experimental Studies of Dust Suction Irregularity from Multi-Cyclone Dust Collector of Two-Stage Air Filter

The necessity of two-stage (multi-cyclone-baffle) inlet air filters used for motor vehicle engines operating under dusty conditions was demonstrated. The advantages of a set of several dozen cyclones (multi-cyclone) used for filtering inlet air in the engines were shown. The problem of dust accumula...

Full description

Bibliographic Details
Main Author: Tadeusz Dziubak
Format: Article
Language:English
Published: MDPI AG 2021-06-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/14/12/3577
_version_ 1797529957067390976
author Tadeusz Dziubak
author_facet Tadeusz Dziubak
author_sort Tadeusz Dziubak
collection DOAJ
description The necessity of two-stage (multi-cyclone-baffle) inlet air filters used for motor vehicle engines operating under dusty conditions was demonstrated. The advantages of a set of several dozen cyclones (multi-cyclone) used for filtering inlet air in the engines were shown. The problem of dust accumulation separated by the cyclones in the multi-cyclone dust collector and the necessity of its removal on a current basis were analyzed. Methods of removing dust from the dust collector by means of the <i>Q</i><sub>S</sub> suction flow were described. It was demonstrated that the most rational method of forcing the suction flow is the use of the suction flow released from the engine. The study results are presented in this paper and show that the removal (by suction) of the accumulated dust from the dust collector additionally causes a noticeable increase in cyclone filtration efficiency. It was shown that the effective suction flow must not exceed 10–15% of the outlet flow value from the cyclone. It was evidenced that the suction of dust from the dust collector of the multi-cyclone, whose range covers several dozen cyclones, causes a differentiation in the value of the suction flows from the individual cyclones, which decreases the effect of suction and interferers with the proper operation of the cyclone. The use of a proprietary methodology, an experimental study of the irregularity of the suction from the cyclones of two multi-cyclones differing in construction, was performed. Suction flows from the cyclones, which were located at a significant distance from the main suction duct, showed 50% lower values. Possibilities of reducing the irregularity of the suction flows from the several dozen cyclones forming the multi-cyclone are presented.
first_indexed 2024-03-10T10:22:15Z
format Article
id doaj.art-30770cc81dcc410482d73acf18a3f714
institution Directory Open Access Journal
issn 1996-1073
language English
last_indexed 2024-03-10T10:22:15Z
publishDate 2021-06-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj.art-30770cc81dcc410482d73acf18a3f7142023-11-22T00:19:41ZengMDPI AGEnergies1996-10732021-06-011412357710.3390/en14123577Experimental Studies of Dust Suction Irregularity from Multi-Cyclone Dust Collector of Two-Stage Air FilterTadeusz Dziubak0Faculty of Mechanical Engineering, Military University of Technology, 2 gen. Sylwestra Kaliskiego St., 00-908 Warsaw, PolandThe necessity of two-stage (multi-cyclone-baffle) inlet air filters used for motor vehicle engines operating under dusty conditions was demonstrated. The advantages of a set of several dozen cyclones (multi-cyclone) used for filtering inlet air in the engines were shown. The problem of dust accumulation separated by the cyclones in the multi-cyclone dust collector and the necessity of its removal on a current basis were analyzed. Methods of removing dust from the dust collector by means of the <i>Q</i><sub>S</sub> suction flow were described. It was demonstrated that the most rational method of forcing the suction flow is the use of the suction flow released from the engine. The study results are presented in this paper and show that the removal (by suction) of the accumulated dust from the dust collector additionally causes a noticeable increase in cyclone filtration efficiency. It was shown that the effective suction flow must not exceed 10–15% of the outlet flow value from the cyclone. It was evidenced that the suction of dust from the dust collector of the multi-cyclone, whose range covers several dozen cyclones, causes a differentiation in the value of the suction flows from the individual cyclones, which decreases the effect of suction and interferers with the proper operation of the cyclone. The use of a proprietary methodology, an experimental study of the irregularity of the suction from the cyclones of two multi-cyclones differing in construction, was performed. Suction flows from the cyclones, which were located at a significant distance from the main suction duct, showed 50% lower values. Possibilities of reducing the irregularity of the suction flows from the several dozen cyclones forming the multi-cyclone are presented.https://www.mdpi.com/1996-1073/14/12/3577engineair filtermulticyclonedust suctiondust suction irregularityair filtration efficiency and accuracy
spellingShingle Tadeusz Dziubak
Experimental Studies of Dust Suction Irregularity from Multi-Cyclone Dust Collector of Two-Stage Air Filter
Energies
engine
air filter
multicyclone
dust suction
dust suction irregularity
air filtration efficiency and accuracy
title Experimental Studies of Dust Suction Irregularity from Multi-Cyclone Dust Collector of Two-Stage Air Filter
title_full Experimental Studies of Dust Suction Irregularity from Multi-Cyclone Dust Collector of Two-Stage Air Filter
title_fullStr Experimental Studies of Dust Suction Irregularity from Multi-Cyclone Dust Collector of Two-Stage Air Filter
title_full_unstemmed Experimental Studies of Dust Suction Irregularity from Multi-Cyclone Dust Collector of Two-Stage Air Filter
title_short Experimental Studies of Dust Suction Irregularity from Multi-Cyclone Dust Collector of Two-Stage Air Filter
title_sort experimental studies of dust suction irregularity from multi cyclone dust collector of two stage air filter
topic engine
air filter
multicyclone
dust suction
dust suction irregularity
air filtration efficiency and accuracy
url https://www.mdpi.com/1996-1073/14/12/3577
work_keys_str_mv AT tadeuszdziubak experimentalstudiesofdustsuctionirregularityfrommulticyclonedustcollectoroftwostageairfilter