Studi Uji Kesesuaian Selisih Lapangan Kolimasi pada Pesawat Mammografi Analog dan Digital

Study of collimation field difference suitability test on analog and digital mammography at leading hospital in Makassar from 2016-2018. This test was carried out by using four coins of the same size placed on the edge of the collimator lamp field, one different size coin was placed on the table edg...

Full description

Bibliographic Details
Main Authors: Fitriani Fitriani, Bualkar Abdullah, Dahlang Tahir
Format: Article
Language:English
Published: Lambung Mangkurat University Press 2019-08-01
Series:Jurnal Fisika Flux
Subjects:
Online Access:https://ppjp.ulm.ac.id/journal/index.php/f/article/view/6344
_version_ 1818475875909238784
author Fitriani Fitriani
Bualkar Abdullah
Dahlang Tahir
author_facet Fitriani Fitriani
Bualkar Abdullah
Dahlang Tahir
author_sort Fitriani Fitriani
collection DOAJ
description Study of collimation field difference suitability test on analog and digital mammography at leading hospital in Makassar from 2016-2018. This test was carried out by using four coins of the same size placed on the edge of the collimator lamp field, one different size coin was placed on the table edge of the chest wall section, and one coin was placed on the surface under the compression pedal to coincide with the edge of the chest wall. The results of the p value obtained for each measurement point, both for the difference of the light collimation field toward the X-ray beam and the difference of X-ray beam collimation field toward image receptor have the same value of 0.000 (p < 0.05). This value states that there are significant differences in the collimation field difference from 2016-2018. The results of collimation field difference suitability test on analog and digital mammography are still within the tolerance limits recommended by BAPETEN, for the difference of the light collimation field toward X-ray beam ≤ 1% SID and the difference of X-ray beam collimation field toward image receptor ≤ 2% SID. This shows that mammography is feasible and able to operate safely for patients and non-patients.
first_indexed 2024-12-10T09:18:21Z
format Article
id doaj.art-3092e34581f34a21824c432bbf2b19ee
institution Directory Open Access Journal
issn 1829-796X
2541-1713
language English
last_indexed 2024-12-10T09:18:21Z
publishDate 2019-08-01
publisher Lambung Mangkurat University Press
record_format Article
series Jurnal Fisika Flux
spelling doaj.art-3092e34581f34a21824c432bbf2b19ee2022-12-22T01:54:46ZengLambung Mangkurat University PressJurnal Fisika Flux1829-796X2541-17132019-08-011629710210.20527/flux.v16i2.63445419Studi Uji Kesesuaian Selisih Lapangan Kolimasi pada Pesawat Mammografi Analog dan DigitalFitriani Fitriani0Bualkar Abdullah1Dahlang Tahir2Jurusan Fisika Universitas HasanuddinJurusan Fisika Universitas HasanuddinJurusan Fisika Universitas HasanuddinStudy of collimation field difference suitability test on analog and digital mammography at leading hospital in Makassar from 2016-2018. This test was carried out by using four coins of the same size placed on the edge of the collimator lamp field, one different size coin was placed on the table edge of the chest wall section, and one coin was placed on the surface under the compression pedal to coincide with the edge of the chest wall. The results of the p value obtained for each measurement point, both for the difference of the light collimation field toward the X-ray beam and the difference of X-ray beam collimation field toward image receptor have the same value of 0.000 (p < 0.05). This value states that there are significant differences in the collimation field difference from 2016-2018. The results of collimation field difference suitability test on analog and digital mammography are still within the tolerance limits recommended by BAPETEN, for the difference of the light collimation field toward X-ray beam ≤ 1% SID and the difference of X-ray beam collimation field toward image receptor ≤ 2% SID. This shows that mammography is feasible and able to operate safely for patients and non-patients.https://ppjp.ulm.ac.id/journal/index.php/f/article/view/6344analogcollimationdigitalmammographyx-ray.
spellingShingle Fitriani Fitriani
Bualkar Abdullah
Dahlang Tahir
Studi Uji Kesesuaian Selisih Lapangan Kolimasi pada Pesawat Mammografi Analog dan Digital
Jurnal Fisika Flux
analog
collimation
digital
mammography
x-ray.
title Studi Uji Kesesuaian Selisih Lapangan Kolimasi pada Pesawat Mammografi Analog dan Digital
title_full Studi Uji Kesesuaian Selisih Lapangan Kolimasi pada Pesawat Mammografi Analog dan Digital
title_fullStr Studi Uji Kesesuaian Selisih Lapangan Kolimasi pada Pesawat Mammografi Analog dan Digital
title_full_unstemmed Studi Uji Kesesuaian Selisih Lapangan Kolimasi pada Pesawat Mammografi Analog dan Digital
title_short Studi Uji Kesesuaian Selisih Lapangan Kolimasi pada Pesawat Mammografi Analog dan Digital
title_sort studi uji kesesuaian selisih lapangan kolimasi pada pesawat mammografi analog dan digital
topic analog
collimation
digital
mammography
x-ray.
url https://ppjp.ulm.ac.id/journal/index.php/f/article/view/6344
work_keys_str_mv AT fitrianifitriani studiujikesesuaianselisihlapangankolimasipadapesawatmammografianalogdandigital
AT bualkarabdullah studiujikesesuaianselisihlapangankolimasipadapesawatmammografianalogdandigital
AT dahlangtahir studiujikesesuaianselisihlapangankolimasipadapesawatmammografianalogdandigital