Direct determination of Calcium in milk by atomic absorption spectrometry using flow-injection analysis

A flow-injection system with sample and reagent addition by the synchronous merging zones approach for calcium determination in milk by flame AAS is proposed. Main parameters were optimized using a factorial design with central point. The optimum conditions were 2.5% (m/v) for La concentration, 8 mL...

Full description

Bibliographic Details
Main Authors: M. B. Petrovich, Volnei Resta Amorim Filho, José Anchieta Gomes Neto Mail
Format: Article
Language:English
Published: Universidade Estadual Paulista 2018-09-01
Series:Eclética Química
Online Access:https://revista.iq.unesp.br/ojs/index.php/ecletica/article/view/999
_version_ 1830491904024772608
author M. B. Petrovich
Volnei Resta Amorim Filho
José Anchieta Gomes Neto Mail
author_facet M. B. Petrovich
Volnei Resta Amorim Filho
José Anchieta Gomes Neto Mail
author_sort M. B. Petrovich
collection DOAJ
description A flow-injection system with sample and reagent addition by the synchronous merging zones approach for calcium determination in milk by flame AAS is proposed. Main parameters were optimized using a factorial design with central point. The optimum conditions were 2.5% (m/v) for La concentration, 8 mL min -1 for the carrier flow-rate, 20 cm for coiled reactor and 250 ìL for sample volume. Different sample preparation procedures were evaluated such as dilution in water or acid and microwave-assisted decomposition using concentrated or diluted acids. The optimized flow system was applied to determine Ca in eleven commercial milk samples and two standard reference materials diluted in water. Similar calcium levels were encountered comparing the results obtained by the proposed method (dilution in water) with those obtained using microwave-oven digestion. Results obtained in two standard reference materials were in agreement at 95% confidence level with those certified. Recoveries of spiked samples were in the 93% - 116% range. Relative standard deviation (n = 12) was < 5.4% and the sample throughput was 150 measurements per hour, corresponding to a consumption of 250 μL of sample and 6.25 mg La per determination.
first_indexed 2024-12-21T20:19:27Z
format Article
id doaj.art-30bc6988382546fdb41bc91e9fa7fefb
institution Directory Open Access Journal
issn 1678-4618
language English
last_indexed 2024-12-21T20:19:27Z
publishDate 2018-09-01
publisher Universidade Estadual Paulista
record_format Article
series Eclética Química
spelling doaj.art-30bc6988382546fdb41bc91e9fa7fefb2022-12-21T18:51:31ZengUniversidade Estadual PaulistaEclética Química1678-46182018-09-01323253010.26850/1678-4618eqj.v32.3.2007.p25-30999Direct determination of Calcium in milk by atomic absorption spectrometry using flow-injection analysisM. B. Petrovich0Volnei Resta Amorim Filho1José Anchieta Gomes Neto Mail2Departamento de Química Analítica, Instituto de Química, Universidade Estadual Paulista, P.O. Box 355, 14801-970 Araraquara - SP, BrazilDepartamento de Química Analítica, Instituto de Química, Universidade Estadual Paulista, P.O. Box 355, 14801-970 Araraquara - SP, BrazilDepartamento de Química Analítica, Instituto de Química, Universidade Estadual Paulista, P.O. Box 355, 14801-970 Araraquara - SP, BrazilA flow-injection system with sample and reagent addition by the synchronous merging zones approach for calcium determination in milk by flame AAS is proposed. Main parameters were optimized using a factorial design with central point. The optimum conditions were 2.5% (m/v) for La concentration, 8 mL min -1 for the carrier flow-rate, 20 cm for coiled reactor and 250 ìL for sample volume. Different sample preparation procedures were evaluated such as dilution in water or acid and microwave-assisted decomposition using concentrated or diluted acids. The optimized flow system was applied to determine Ca in eleven commercial milk samples and two standard reference materials diluted in water. Similar calcium levels were encountered comparing the results obtained by the proposed method (dilution in water) with those obtained using microwave-oven digestion. Results obtained in two standard reference materials were in agreement at 95% confidence level with those certified. Recoveries of spiked samples were in the 93% - 116% range. Relative standard deviation (n = 12) was < 5.4% and the sample throughput was 150 measurements per hour, corresponding to a consumption of 250 μL of sample and 6.25 mg La per determination.https://revista.iq.unesp.br/ojs/index.php/ecletica/article/view/999
spellingShingle M. B. Petrovich
Volnei Resta Amorim Filho
José Anchieta Gomes Neto Mail
Direct determination of Calcium in milk by atomic absorption spectrometry using flow-injection analysis
Eclética Química
title Direct determination of Calcium in milk by atomic absorption spectrometry using flow-injection analysis
title_full Direct determination of Calcium in milk by atomic absorption spectrometry using flow-injection analysis
title_fullStr Direct determination of Calcium in milk by atomic absorption spectrometry using flow-injection analysis
title_full_unstemmed Direct determination of Calcium in milk by atomic absorption spectrometry using flow-injection analysis
title_short Direct determination of Calcium in milk by atomic absorption spectrometry using flow-injection analysis
title_sort direct determination of calcium in milk by atomic absorption spectrometry using flow injection analysis
url https://revista.iq.unesp.br/ojs/index.php/ecletica/article/view/999
work_keys_str_mv AT mbpetrovich directdeterminationofcalciuminmilkbyatomicabsorptionspectrometryusingflowinjectionanalysis
AT volneirestaamorimfilho directdeterminationofcalciuminmilkbyatomicabsorptionspectrometryusingflowinjectionanalysis
AT joseanchietagomesnetomail directdeterminationofcalciuminmilkbyatomicabsorptionspectrometryusingflowinjectionanalysis