Low-Cost Polyethylene Terephthalate Fluidic Sensor for Ultrahigh Accuracy Measurement of Liquid Concentration Variation
A low-cost polyethylene terephthalate fluidic sensor (PET-FS) is demonstrated for the concentration variation measurement on fluidic solutions. The PET-FS consisted of a triangular fluidic container attached with a birefringent PET thin layer. The PET-FS was injected with the test liquid solution th...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2021-11-01
|
Series: | Sensors |
Subjects: | |
Online Access: | https://www.mdpi.com/1424-8220/21/21/7410 |
_version_ | 1797511694678753280 |
---|---|
author | Ruey-Ching Twu Kai-Hsuan Li Bo-Lin Lin |
author_facet | Ruey-Ching Twu Kai-Hsuan Li Bo-Lin Lin |
author_sort | Ruey-Ching Twu |
collection | DOAJ |
description | A low-cost polyethylene terephthalate fluidic sensor (PET-FS) is demonstrated for the concentration variation measurement on fluidic solutions. The PET-FS consisted of a triangular fluidic container attached with a birefringent PET thin layer. The PET-FS was injected with the test liquid solution that was placed in a common path polarization interferometer by utilizing a heterodyne scheme. The measured phase variation of probe light was used to obtain the information regarding the concentration change in the fluidic liquids. The sensor was experimentally tested using different concentrations of sodium chloride solution showing a sensitivity of 3.52 ×10<sup>4</sup> deg./refractive index unit (RIU) and a detection resolution of 6.25 × 10<sup>−6</sup> RIU. The estimated sensitivity and detection resolutions were 5.62 × 10<sup>4</sup> (deg./RIU) and 6.94 × 10<sup>−6</sup> RIU, respectively, for the hydrochloric acid. The relationship between the measured phase and the concentration is linear with an R-squared value reaching above 0.995. |
first_indexed | 2024-03-10T05:51:43Z |
format | Article |
id | doaj.art-30c3dc6280e5431e8e3d39a8381d4440 |
institution | Directory Open Access Journal |
issn | 1424-8220 |
language | English |
last_indexed | 2024-03-10T05:51:43Z |
publishDate | 2021-11-01 |
publisher | MDPI AG |
record_format | Article |
series | Sensors |
spelling | doaj.art-30c3dc6280e5431e8e3d39a8381d44402023-11-22T21:41:12ZengMDPI AGSensors1424-82202021-11-012121741010.3390/s21217410Low-Cost Polyethylene Terephthalate Fluidic Sensor for Ultrahigh Accuracy Measurement of Liquid Concentration VariationRuey-Ching Twu0Kai-Hsuan Li1Bo-Lin Lin2Department of Electro-Optical Engineering, Southern Taiwan University of Science and Technology, Tainan 71005, TaiwanDepartment of Electro-Optical Engineering, Southern Taiwan University of Science and Technology, Tainan 71005, TaiwanDepartment of Electro-Optical Engineering, Southern Taiwan University of Science and Technology, Tainan 71005, TaiwanA low-cost polyethylene terephthalate fluidic sensor (PET-FS) is demonstrated for the concentration variation measurement on fluidic solutions. The PET-FS consisted of a triangular fluidic container attached with a birefringent PET thin layer. The PET-FS was injected with the test liquid solution that was placed in a common path polarization interferometer by utilizing a heterodyne scheme. The measured phase variation of probe light was used to obtain the information regarding the concentration change in the fluidic liquids. The sensor was experimentally tested using different concentrations of sodium chloride solution showing a sensitivity of 3.52 ×10<sup>4</sup> deg./refractive index unit (RIU) and a detection resolution of 6.25 × 10<sup>−6</sup> RIU. The estimated sensitivity and detection resolutions were 5.62 × 10<sup>4</sup> (deg./RIU) and 6.94 × 10<sup>−6</sup> RIU, respectively, for the hydrochloric acid. The relationship between the measured phase and the concentration is linear with an R-squared value reaching above 0.995.https://www.mdpi.com/1424-8220/21/21/7410low costpolyethylene terephthalatefluidic sensorbirefringencephase measurementpolarization interferometer |
spellingShingle | Ruey-Ching Twu Kai-Hsuan Li Bo-Lin Lin Low-Cost Polyethylene Terephthalate Fluidic Sensor for Ultrahigh Accuracy Measurement of Liquid Concentration Variation Sensors low cost polyethylene terephthalate fluidic sensor birefringence phase measurement polarization interferometer |
title | Low-Cost Polyethylene Terephthalate Fluidic Sensor for Ultrahigh Accuracy Measurement of Liquid Concentration Variation |
title_full | Low-Cost Polyethylene Terephthalate Fluidic Sensor for Ultrahigh Accuracy Measurement of Liquid Concentration Variation |
title_fullStr | Low-Cost Polyethylene Terephthalate Fluidic Sensor for Ultrahigh Accuracy Measurement of Liquid Concentration Variation |
title_full_unstemmed | Low-Cost Polyethylene Terephthalate Fluidic Sensor for Ultrahigh Accuracy Measurement of Liquid Concentration Variation |
title_short | Low-Cost Polyethylene Terephthalate Fluidic Sensor for Ultrahigh Accuracy Measurement of Liquid Concentration Variation |
title_sort | low cost polyethylene terephthalate fluidic sensor for ultrahigh accuracy measurement of liquid concentration variation |
topic | low cost polyethylene terephthalate fluidic sensor birefringence phase measurement polarization interferometer |
url | https://www.mdpi.com/1424-8220/21/21/7410 |
work_keys_str_mv | AT rueychingtwu lowcostpolyethyleneterephthalatefluidicsensorforultrahighaccuracymeasurementofliquidconcentrationvariation AT kaihsuanli lowcostpolyethyleneterephthalatefluidicsensorforultrahighaccuracymeasurementofliquidconcentrationvariation AT bolinlin lowcostpolyethyleneterephthalatefluidicsensorforultrahighaccuracymeasurementofliquidconcentrationvariation |