Experimental Validation of Current Sensors Fault Detection and Tolerant Control Strategy for Three-Phase Permanent Magnet Synchronous Motor Drives
This paper presents the experimental validation of a Fault-Tolerant Control (FTC) system for Permanent Magnet Synchronous Motor (PMSM) drives, specifically focusing on current sensors. The FTC system is designed to detect and diagnose both single and multiple faults in the current sensors and to rec...
Main Authors: | Younes Azzoug, Remus Pusca, Mohamed Sahraoui, Tarek Ameid, Raphael Romary |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2023-08-01
|
Series: | Machines |
Subjects: | |
Online Access: | https://www.mdpi.com/2075-1702/11/9/873 |
Similar Items
-
Fault-Tolerant Control for Reducing Harmonic Distortion of Dual Three-Phase Permanent Magnet Synchronous Motor
by: Liping Zhao, et al.
Published: (2022-05-01) -
Fault-Tolerant Control Strategy for 12-Phase Permanent Magnet Synchronous Motor
by: Hanying Gao, et al.
Published: (2019-09-01) -
Review of fault diagnosis methods for permanent magnet synchronous motors
by: MA Jian, et al.
Published: (2024-07-01) -
Adaptive Fault-Tolerant Control for Flexible Variable Structure Spacecraft with Actuator Saturation and Multiple Faults
by: Kai-Yu Hu, et al.
Published: (2022-05-01) -
Sensors Fault Diagnosis and Active Fault-Tolerant Control for PMSM Drive Systems Based on a Composite Sliding Mode Observer
by: Qinyue Zhu, et al.
Published: (2019-05-01)