Development of Precise Low Value Capacitance Measurement System for Cryogenics Two Phase Flow Application
In cryogenic two phase flow, it is always challenging to measure the quality and void fraction. In this regard, an effort has been made to indigenously develop an electronic circuit to measure the void fraction by measuring the capacitance of the order of picofarads accurately depending upon the die...
Main Authors: | SINGH Gaurav Kumar, PURWAR Gaurav, PATEL Rakesh, TANNA Vipul L., PRADHAN Subrata |
---|---|
Format: | Article |
Language: | English |
Published: |
Editura Universităţii din Oradea
2018-10-01
|
Series: | Journal of Electrical and Electronics Engineering |
Subjects: | |
Online Access: | http://electroinf.uoradea.ro/images/articles/CERCETARE/Reviste/JEEE/JEEE_V11_N2_OCT_2018/05paper1130SINGH.pdf |
Similar Items
-
Void Fraction Measurement System for Steady State Horizontal Two Phase Liquid Nitrogen Flow
by: SINGH G. K., et al.
Published: (2021-05-01) -
Development study of a capacitance void fraction sensor using asymmetrical electrode plates
by: Yuki SAKAMOTO, et al.
Published: (2016-02-01) -
A New Capacitance Sensor for Measuring the Void Fraction of Two-Phase Flow Through Tube Bundles
by: Wael Ahmed, et al.
Published: (2020-04-01) -
Experimental Study of Void Fraction Measurement Using a Capacitance-Based Sensor and ANN in Two-Phase Annular Regimes for Different Fluids
by: Aryan Veisi, et al.
Published: (2023-01-01) -
Multi-dimensional void fraction measurement of transient boiling two-phase flow in a heated rod bundle
by: Takahiro ARAI, et al.
Published: (2015-07-01)