Identifikasi Lokasi Gangguan Pada Penyulang Baugan ULP Denpasar Dengan Metode Naïve Bayes

One of the problems in the distribution of electrical power is the identification of the location of the disturbance in the distribution network of pt pln. Several methods have been proposed to determine the location of the disturbance including the nearest neighbor method, impedance method and nave...

Full description

Bibliographic Details
Main Authors: Riska Suryanti Putri, Sabar Setiawidayat, Gigih Priyandoko
Format: Article
Language:English
Published: Khairun University, Faculty of Engineering, Department of Electrical Engineering 2022-05-01
Series:Protek: Jurnal Ilmiah Teknik Elektro
Subjects:
Online Access:https://ejournal.unkhair.ac.id/index.php/protk/article/view/3517
_version_ 1797965606436208640
author Riska Suryanti Putri
Sabar Setiawidayat
Gigih Priyandoko
author_facet Riska Suryanti Putri
Sabar Setiawidayat
Gigih Priyandoko
author_sort Riska Suryanti Putri
collection DOAJ
description One of the problems in the distribution of electrical power is the identification of the location of the disturbance in the distribution network of pt pln. Several methods have been proposed to determine the location of the disturbance including the nearest neighbor method, impedance method and nave bayes method, in this study the author proposes the naïve bayes method. The naïve bayes method is a classification method based on simple probability and is designed to be used with the assumption that between one class and another class are not mutually dependent (independent). In the naïve bayes classification, the learning process is more focused on estimating probabilities. From the results of the experiment using 30 samples, the average error value for comparison of identification using the nave bayes method and the direct tracing method in identifying the location of disturbances in the buagan feeder was 0.86% with an average difference between the actual distance and the distance in the program of 30.9 meters. . The results of the comparative analysis using paired samples statistics showed no significant difference at 0.05. In the results of the comparative analysis using anova one way at 0.01 there is no significant difference. This study serves to narrow the direct line area for handling electrical disturbances on the 20 kv network, so that in the event of an electrical disturbance on the 20 kv network it does not take a long time in the process of identifying the location of the electrical disturbance.
first_indexed 2024-04-11T02:02:42Z
format Article
id doaj.art-31bd2befc6e0431bae18f8609b045275
institution Directory Open Access Journal
issn 2354-8924
2527-9572
language English
last_indexed 2024-04-11T02:02:42Z
publishDate 2022-05-01
publisher Khairun University, Faculty of Engineering, Department of Electrical Engineering
record_format Article
series Protek: Jurnal Ilmiah Teknik Elektro
spelling doaj.art-31bd2befc6e0431bae18f8609b0452752023-01-03T03:45:10ZengKhairun University, Faculty of Engineering, Department of Electrical EngineeringProtek: Jurnal Ilmiah Teknik Elektro2354-89242527-95722022-05-019191410.33387/protk.v9i1.35172467Identifikasi Lokasi Gangguan Pada Penyulang Baugan ULP Denpasar Dengan Metode Naïve BayesRiska Suryanti Putri0Sabar Setiawidayat1Gigih Priyandoko2Fakultas Teknik, Jurusan Teknik Elektro Universitas Widyagama MalangFakultas Teknik, Jurusan Teknik Elektro Universitas Widyagama MalangFakultas Teknik, Jurusan Teknik Elektro Universitas Widyagama MalangOne of the problems in the distribution of electrical power is the identification of the location of the disturbance in the distribution network of pt pln. Several methods have been proposed to determine the location of the disturbance including the nearest neighbor method, impedance method and nave bayes method, in this study the author proposes the naïve bayes method. The naïve bayes method is a classification method based on simple probability and is designed to be used with the assumption that between one class and another class are not mutually dependent (independent). In the naïve bayes classification, the learning process is more focused on estimating probabilities. From the results of the experiment using 30 samples, the average error value for comparison of identification using the nave bayes method and the direct tracing method in identifying the location of disturbances in the buagan feeder was 0.86% with an average difference between the actual distance and the distance in the program of 30.9 meters. . The results of the comparative analysis using paired samples statistics showed no significant difference at 0.05. In the results of the comparative analysis using anova one way at 0.01 there is no significant difference. This study serves to narrow the direct line area for handling electrical disturbances on the 20 kv network, so that in the event of an electrical disturbance on the 20 kv network it does not take a long time in the process of identifying the location of the electrical disturbance.https://ejournal.unkhair.ac.id/index.php/protk/article/view/3517electrical disturbancenaïve bayes methodfeederdistribution networkcomparative analysis
spellingShingle Riska Suryanti Putri
Sabar Setiawidayat
Gigih Priyandoko
Identifikasi Lokasi Gangguan Pada Penyulang Baugan ULP Denpasar Dengan Metode Naïve Bayes
Protek: Jurnal Ilmiah Teknik Elektro
electrical disturbance
naïve bayes method
feeder
distribution network
comparative analysis
title Identifikasi Lokasi Gangguan Pada Penyulang Baugan ULP Denpasar Dengan Metode Naïve Bayes
title_full Identifikasi Lokasi Gangguan Pada Penyulang Baugan ULP Denpasar Dengan Metode Naïve Bayes
title_fullStr Identifikasi Lokasi Gangguan Pada Penyulang Baugan ULP Denpasar Dengan Metode Naïve Bayes
title_full_unstemmed Identifikasi Lokasi Gangguan Pada Penyulang Baugan ULP Denpasar Dengan Metode Naïve Bayes
title_short Identifikasi Lokasi Gangguan Pada Penyulang Baugan ULP Denpasar Dengan Metode Naïve Bayes
title_sort identifikasi lokasi gangguan pada penyulang baugan ulp denpasar dengan metode naive bayes
topic electrical disturbance
naïve bayes method
feeder
distribution network
comparative analysis
url https://ejournal.unkhair.ac.id/index.php/protk/article/view/3517
work_keys_str_mv AT riskasuryantiputri identifikasilokasigangguanpadapenyulangbauganulpdenpasardenganmetodenaivebayes
AT sabarsetiawidayat identifikasilokasigangguanpadapenyulangbauganulpdenpasardenganmetodenaivebayes
AT gigihpriyandoko identifikasilokasigangguanpadapenyulangbauganulpdenpasardenganmetodenaivebayes