Non-uniform electric field-induced yeast cell electrokinetic behavior

Common dielectrophoresis (c-DEP, i.e. neutral matter motion induced by non-uniform electric fields) has become a basic pheno-menon of biochips intended for medical, biological and chemical assays, especially when they imply bioparticle handling. This paper deals with modelling and experimental verif...

Full description

Bibliographic Details
Main Authors: Flavio Humberto Fernández Morales, Julio Enrique Duarte, Joseph Samitier Martí
Format: Article
Language:English
Published: Universidad Nacional de Colombia 2008-09-01
Series:Ingeniería e Investigación
Subjects:
Online Access:https://revistas.unal.edu.co/index.php/ingeinv/article/view/15129
Description
Summary:Common dielectrophoresis (c-DEP, i.e. neutral matter motion induced by non-uniform electric fields) has become a basic pheno-menon of biochips intended for medical, biological and chemical assays, especially when they imply bioparticle handling. This paper deals with modelling and experimental verification of a castellated, c-DEP-based, microelectrode array intended to handle biological objects. The proposed microsystem was developed employing platinum electrodes patterned by lift-off, silicon micro-machining and photoresin patterning techniques. Saccharomyces cerevisiae were used as test bioparticles for experimental verifi-cation. Yeast cells were repelled toward electrode bays and toward interelectrodic gaps tor frequencies around 20 MHz where there is minimum electric field strength, corresponding to a negative dielectrophoretic phenomenon. Yeast cell agglomerations were observed around electrode edges for frequencies of around 2 MHz where there is maximum electric field strength, thereby verifying the positive dielectrophoretic phenomenon. Bioparticles were separated from the electrode edges when the working fre-quency was reduced and they were dragged towards the electrode centre, remaining there while the frequency was low enough. Such atypical pattern may be explained due to the occurrence of positive dielectrophoresis overlap with electrohydrodynamic effects (i.e. the viscous drag force acting on the particles was greater than the dielectrophoretic force at frequencies where positi-ve dielectrophoresis should occur). The experiments illustrated microsystem convenience in microhandling biological objects, the-reby providing these microarrays’ possible use with other cells. Liquid motion resulting from electrohydrodynamic effects must also be taken into account when designing bioparticle micromanipulators, and could be used as a mechanism for cleaning electrode surfaces.
ISSN:0120-5609
2248-8723