Rehabilitation of Corrosion-Defected RC Beam-Column Members Using Patch Repair Technique
An experimental study was conducted to evaluate the efficiency of patch repair to rehabilitate corrosion-defected reinforced concrete (RC) beam-column members when exposed to bending moments and axial forces. Ten RC beam-column members were tested under combined constant axial force and four-point t...