The compatibility of denture cleansers and resilient liners Influência dos agentes químicos de limpeza sobre reembasadores resilientes de próteses

PURPOSE: Difficulty in cleaning resilient denture liners remains a material disadvantage. The purpose of the present study was to evaluate the effect of denture cleansers on hardness of resilient liner materials. MATERIALS AND METHODS: Three resilient liners, Luci Sof® (Dentsply), Molloplast-B® (Den...

Full description

Bibliographic Details
Main Authors: Luciana Valadares Oliveira, Marcelo Ferraz Mesquita, Guilherme Elias Pessanha Henriques, Rafael Leonardo Xediek Consani, Wagner Sotero Fragoso
Format: Article
Language:English
Published: University of São Paulo 2006-08-01
Series:Journal of Applied Oral Science
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572006000400014
_version_ 1818683206939967488
author Luciana Valadares Oliveira
Marcelo Ferraz Mesquita
Guilherme Elias Pessanha Henriques
Rafael Leonardo Xediek Consani
Wagner Sotero Fragoso
author_facet Luciana Valadares Oliveira
Marcelo Ferraz Mesquita
Guilherme Elias Pessanha Henriques
Rafael Leonardo Xediek Consani
Wagner Sotero Fragoso
author_sort Luciana Valadares Oliveira
collection DOAJ
description PURPOSE: Difficulty in cleaning resilient denture liners remains a material disadvantage. The purpose of the present study was to evaluate the effect of denture cleansers on hardness of resilient liner materials. MATERIALS AND METHODS: Three resilient liners, Luci Sof® (Dentsply), Molloplast-B® (Dentax), and Sofreliner® (Tokuyama), and two denture cleansers, Efferdent® (Warner-Lamber), and 0.5% alkaline hypochlorite preparation were used. Twenty specimens of each material were prepared, measuring 25X15X3mm. Two denture cleansing approaches were used: 1) alkaline hypochlorite, for 20 minutes; 2) alkaline peroxide, for 30 minutes. This procedure was repeated 8 times a day, during 90 days. The specimens were evaluated before and after 360 and 720 cycles, to simulate 1 and 2 years of clinical cleaning procedures, respectively. The Shore A hardness was evaluated in a durometer (Teclock GS-709A), with a penetrating load of 10N for 1 second. Any macroscopic changes, such as loss of color or alteration in surface texture were recorded by one observer. All numeric data were subject to ANOVA with repeated measures followed by Tukey's test (alpha= 0.05). RESULTS: All materials were significantly different, independently to time and treatment. Initially, Luci Sof® and Sofreliner® immersed in either hypochlorite or peroxide increased the hardness mean values significantly. These hardness mean values decreased significantly after 720 cycles. Molloplast-B® showed no significant difference after the treatments, in any time. CONCLUSIONS: Denture cleansers had no effect on hardness of the resilient denture liners evaluated after 2 years of in vivo simulated conditions of hygiene. Sofreliner® was the smoothest material before and after all treatments.<br>PROPOSIÇÃO: A maior desvantagem dos materiais reembasadores resilientes é a dificuldade em mantê-los limpos. Esse trabalho avaliou o efeito de agentes de limpeza sobre a dureza de reembasadores resilientes. MATERIAL E MÉTODOS: Foram utilizados os materiais Luci Sof® (Dentsply), Molloplast-B® (Dentax) e Sofreliner® (Tokuyama), e os agentes de limpeza Hipoclorito de Sódio a 0,5% (Medicinallis-Farmácia de Manipulação) e Efferdent® (Warner-Lamber). Foram confeccionadas 20 amostras de cada material, com dimensões de 25X14X3mm. Foram realizados 2 tratamentos: 1) Hipoclorito de Sódio a 0,5% a 37 + 1ºC, durante 20 minutos; 2) Peróxido Alcalino, a 37 + 1ºC, durante 30 minutos. Após as imersões, as amostras foram lavadas e imersas em água destilada, a 37 &plusmn; 1ºC, pelo período restante das 24 h. Esse processo foi repetido 8 vezes por dia, durante 90 dias. A dureza foi avaliada antes e após 360 e 720 ciclos, correspondente a 1 e 2 anos de uso clínico, respectivamente. O ensaio de dureza Shore A foi realizado em durômetro modelo GS-709 (Teclock-Japão), com aplicação de carga de 10 N por 1 segundo. Alterações macroscópicas, como perda de cor e alteração da superfície, foram avaliadas por um observador. Os resultados obtidos foram submetidos à ANOVA com medidas repetidas e ao Teste de Tukey (5%). RESULTADOS: Os materiais apresentaram diferença significante nos valores médios de dureza, independente do tratamento e do tempo. Luci Sof® e Sofreliner® aumentaram os valores médios de dureza inicialmente, os quais diminuíram após 720 ciclos significativamente, para ambos os tratamentos. Molloplast-B® não apresentou diferença significante nos diferentes tempos e tratamentos. CONCLUSÕES: Os tratamentos em agentes de limpeza não alteraram os valores de dureza dos reembasadores resilientes após 2 anos de simulação clínica. Sofreliner® apresentou os menores valores de dureza, em todos os tempos e tratamentos, apresentando-se como o material mais macio.
first_indexed 2024-12-17T10:31:04Z
format Article
id doaj.art-326b694160064cd580217477fd13b14c
institution Directory Open Access Journal
issn 1678-7757
1678-7765
language English
last_indexed 2024-12-17T10:31:04Z
publishDate 2006-08-01
publisher University of São Paulo
record_format Article
series Journal of Applied Oral Science
spelling doaj.art-326b694160064cd580217477fd13b14c2022-12-21T21:52:30ZengUniversity of São PauloJournal of Applied Oral Science1678-77571678-77652006-08-0114428629010.1590/S1678-77572006000400014The compatibility of denture cleansers and resilient liners Influência dos agentes químicos de limpeza sobre reembasadores resilientes de prótesesLuciana Valadares OliveiraMarcelo Ferraz MesquitaGuilherme Elias Pessanha HenriquesRafael Leonardo Xediek ConsaniWagner Sotero FragosoPURPOSE: Difficulty in cleaning resilient denture liners remains a material disadvantage. The purpose of the present study was to evaluate the effect of denture cleansers on hardness of resilient liner materials. MATERIALS AND METHODS: Three resilient liners, Luci Sof® (Dentsply), Molloplast-B® (Dentax), and Sofreliner® (Tokuyama), and two denture cleansers, Efferdent® (Warner-Lamber), and 0.5% alkaline hypochlorite preparation were used. Twenty specimens of each material were prepared, measuring 25X15X3mm. Two denture cleansing approaches were used: 1) alkaline hypochlorite, for 20 minutes; 2) alkaline peroxide, for 30 minutes. This procedure was repeated 8 times a day, during 90 days. The specimens were evaluated before and after 360 and 720 cycles, to simulate 1 and 2 years of clinical cleaning procedures, respectively. The Shore A hardness was evaluated in a durometer (Teclock GS-709A), with a penetrating load of 10N for 1 second. Any macroscopic changes, such as loss of color or alteration in surface texture were recorded by one observer. All numeric data were subject to ANOVA with repeated measures followed by Tukey's test (alpha= 0.05). RESULTS: All materials were significantly different, independently to time and treatment. Initially, Luci Sof® and Sofreliner® immersed in either hypochlorite or peroxide increased the hardness mean values significantly. These hardness mean values decreased significantly after 720 cycles. Molloplast-B® showed no significant difference after the treatments, in any time. CONCLUSIONS: Denture cleansers had no effect on hardness of the resilient denture liners evaluated after 2 years of in vivo simulated conditions of hygiene. Sofreliner® was the smoothest material before and after all treatments.<br>PROPOSIÇÃO: A maior desvantagem dos materiais reembasadores resilientes é a dificuldade em mantê-los limpos. Esse trabalho avaliou o efeito de agentes de limpeza sobre a dureza de reembasadores resilientes. MATERIAL E MÉTODOS: Foram utilizados os materiais Luci Sof® (Dentsply), Molloplast-B® (Dentax) e Sofreliner® (Tokuyama), e os agentes de limpeza Hipoclorito de Sódio a 0,5% (Medicinallis-Farmácia de Manipulação) e Efferdent® (Warner-Lamber). Foram confeccionadas 20 amostras de cada material, com dimensões de 25X14X3mm. Foram realizados 2 tratamentos: 1) Hipoclorito de Sódio a 0,5% a 37 + 1ºC, durante 20 minutos; 2) Peróxido Alcalino, a 37 + 1ºC, durante 30 minutos. Após as imersões, as amostras foram lavadas e imersas em água destilada, a 37 &plusmn; 1ºC, pelo período restante das 24 h. Esse processo foi repetido 8 vezes por dia, durante 90 dias. A dureza foi avaliada antes e após 360 e 720 ciclos, correspondente a 1 e 2 anos de uso clínico, respectivamente. O ensaio de dureza Shore A foi realizado em durômetro modelo GS-709 (Teclock-Japão), com aplicação de carga de 10 N por 1 segundo. Alterações macroscópicas, como perda de cor e alteração da superfície, foram avaliadas por um observador. Os resultados obtidos foram submetidos à ANOVA com medidas repetidas e ao Teste de Tukey (5%). RESULTADOS: Os materiais apresentaram diferença significante nos valores médios de dureza, independente do tratamento e do tempo. Luci Sof® e Sofreliner® aumentaram os valores médios de dureza inicialmente, os quais diminuíram após 720 ciclos significativamente, para ambos os tratamentos. Molloplast-B® não apresentou diferença significante nos diferentes tempos e tratamentos. CONCLUSÕES: Os tratamentos em agentes de limpeza não alteraram os valores de dureza dos reembasadores resilientes após 2 anos de simulação clínica. Sofreliner® apresentou os menores valores de dureza, em todos os tempos e tratamentos, apresentando-se como o material mais macio.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572006000400014Prótese totalMateriais resilientesSiliconesDurezaDenture, completeResilient denture linerSiliconesHardness
spellingShingle Luciana Valadares Oliveira
Marcelo Ferraz Mesquita
Guilherme Elias Pessanha Henriques
Rafael Leonardo Xediek Consani
Wagner Sotero Fragoso
The compatibility of denture cleansers and resilient liners Influência dos agentes químicos de limpeza sobre reembasadores resilientes de próteses
Journal of Applied Oral Science
Prótese total
Materiais resilientes
Silicones
Dureza
Denture, complete
Resilient denture liner
Silicones
Hardness
title The compatibility of denture cleansers and resilient liners Influência dos agentes químicos de limpeza sobre reembasadores resilientes de próteses
title_full The compatibility of denture cleansers and resilient liners Influência dos agentes químicos de limpeza sobre reembasadores resilientes de próteses
title_fullStr The compatibility of denture cleansers and resilient liners Influência dos agentes químicos de limpeza sobre reembasadores resilientes de próteses
title_full_unstemmed The compatibility of denture cleansers and resilient liners Influência dos agentes químicos de limpeza sobre reembasadores resilientes de próteses
title_short The compatibility of denture cleansers and resilient liners Influência dos agentes químicos de limpeza sobre reembasadores resilientes de próteses
title_sort compatibility of denture cleansers and resilient liners influencia dos agentes quimicos de limpeza sobre reembasadores resilientes de proteses
topic Prótese total
Materiais resilientes
Silicones
Dureza
Denture, complete
Resilient denture liner
Silicones
Hardness
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572006000400014
work_keys_str_mv AT lucianavaladaresoliveira thecompatibilityofdenturecleansersandresilientlinersinfluenciadosagentesquimicosdelimpezasobrereembasadoresresilientesdeproteses
AT marceloferrazmesquita thecompatibilityofdenturecleansersandresilientlinersinfluenciadosagentesquimicosdelimpezasobrereembasadoresresilientesdeproteses
AT guilhermeeliaspessanhahenriques thecompatibilityofdenturecleansersandresilientlinersinfluenciadosagentesquimicosdelimpezasobrereembasadoresresilientesdeproteses
AT rafaelleonardoxediekconsani thecompatibilityofdenturecleansersandresilientlinersinfluenciadosagentesquimicosdelimpezasobrereembasadoresresilientesdeproteses
AT wagnersoterofragoso thecompatibilityofdenturecleansersandresilientlinersinfluenciadosagentesquimicosdelimpezasobrereembasadoresresilientesdeproteses
AT lucianavaladaresoliveira compatibilityofdenturecleansersandresilientlinersinfluenciadosagentesquimicosdelimpezasobrereembasadoresresilientesdeproteses
AT marceloferrazmesquita compatibilityofdenturecleansersandresilientlinersinfluenciadosagentesquimicosdelimpezasobrereembasadoresresilientesdeproteses
AT guilhermeeliaspessanhahenriques compatibilityofdenturecleansersandresilientlinersinfluenciadosagentesquimicosdelimpezasobrereembasadoresresilientesdeproteses
AT rafaelleonardoxediekconsani compatibilityofdenturecleansersandresilientlinersinfluenciadosagentesquimicosdelimpezasobrereembasadoresresilientesdeproteses
AT wagnersoterofragoso compatibilityofdenturecleansersandresilientlinersinfluenciadosagentesquimicosdelimpezasobrereembasadoresresilientesdeproteses