Condition Monitoring of Outdoor High Voltage Insulators, Online and Offline Techniques: A review

 Outdoor insulator plays a vital role in high voltage transmission and distribution system. The performance and properties of outdoor insulator may severely affect due to various types of pollutants. The failure of insulation in high voltage system results in loss of supply and a huge loss of elect...

Full beskrivning

Bibliografiska uppgifter
Huvudupphovsmän: Haseeb Faisal, Arshad Ali, Muhammad Riaz
Materialtyp: Artikel
Språk:English
Publicerad: National University of Sciences and Technology, Islamabad 2021-07-01
Serie:NUST Journal of Engineering Sciences
Ämnen:
Länkar:https://journals.nust.edu.pk/index.php/njes/article/view/627
_version_ 1827980416266534912
author Haseeb Faisal
Arshad Ali
Muhammad Riaz
author_facet Haseeb Faisal
Arshad Ali
Muhammad Riaz
author_sort Haseeb Faisal
collection DOAJ
description  Outdoor insulator plays a vital role in high voltage transmission and distribution system. The performance and properties of outdoor insulator may severely affect due to various types of pollutants. The failure of insulation in high voltage system results in loss of supply and a huge loss of electrical energy to distribution utilities. In order to reduce power losses and provide a reliable power transmission, selection and design of insulators is very important. To monitor the condition and performance of outdoor insulator in contaminated conditions an appropriate diagnostic technique is required. In this paper various online and offline techniques for conditioning monitoring of outdoor insulators are reviewed under different contaminated conditions. To maintain the healthy environment, the condition monitoring of power line insulators is an important requirement. There are number of techniques that have been introduced to fulfil this requirement. Each technique used at different contaminated condition have their own pros and cons. The findings indicate that the most important effect on the surface of the insulators based on the contamination on the surface leakage current and the flashover voltage. This paper will help in the selection and design of condition monitoring techniques for high voltage outdoor insulator.
first_indexed 2024-04-09T21:52:55Z
format Article
id doaj.art-328b6e5aea044b51a2c6bd049f2a87df
institution Directory Open Access Journal
issn 2070-9900
2411-6319
language English
last_indexed 2024-04-09T21:52:55Z
publishDate 2021-07-01
publisher National University of Sciences and Technology, Islamabad
record_format Article
series NUST Journal of Engineering Sciences
spelling doaj.art-328b6e5aea044b51a2c6bd049f2a87df2023-03-24T11:35:12ZengNational University of Sciences and Technology, IslamabadNUST Journal of Engineering Sciences2070-99002411-63192021-07-0114110.24949/njes.v14i1.627496Condition Monitoring of Outdoor High Voltage Insulators, Online and Offline Techniques: A reviewHaseeb Faisal0Arshad Ali1Muhammad Riaz2 Department of Electrical Engineering, HITEC University Taxila, PakistanUniversity of Strathclyde, Glasgow, United Kingdom Department of Electrical Engineering, Wah Engineering College University of Wah, Pakistan  Outdoor insulator plays a vital role in high voltage transmission and distribution system. The performance and properties of outdoor insulator may severely affect due to various types of pollutants. The failure of insulation in high voltage system results in loss of supply and a huge loss of electrical energy to distribution utilities. In order to reduce power losses and provide a reliable power transmission, selection and design of insulators is very important. To monitor the condition and performance of outdoor insulator in contaminated conditions an appropriate diagnostic technique is required. In this paper various online and offline techniques for conditioning monitoring of outdoor insulators are reviewed under different contaminated conditions. To maintain the healthy environment, the condition monitoring of power line insulators is an important requirement. There are number of techniques that have been introduced to fulfil this requirement. Each technique used at different contaminated condition have their own pros and cons. The findings indicate that the most important effect on the surface of the insulators based on the contamination on the surface leakage current and the flashover voltage. This paper will help in the selection and design of condition monitoring techniques for high voltage outdoor insulator. https://journals.nust.edu.pk/index.php/njes/article/view/627Condition monitoringoutdoor insulatorsflashover voltagesurface leakage currenttransmission
spellingShingle Haseeb Faisal
Arshad Ali
Muhammad Riaz
Condition Monitoring of Outdoor High Voltage Insulators, Online and Offline Techniques: A review
NUST Journal of Engineering Sciences
Condition monitoring
outdoor insulators
flashover voltage
surface leakage current
transmission
title Condition Monitoring of Outdoor High Voltage Insulators, Online and Offline Techniques: A review
title_full Condition Monitoring of Outdoor High Voltage Insulators, Online and Offline Techniques: A review
title_fullStr Condition Monitoring of Outdoor High Voltage Insulators, Online and Offline Techniques: A review
title_full_unstemmed Condition Monitoring of Outdoor High Voltage Insulators, Online and Offline Techniques: A review
title_short Condition Monitoring of Outdoor High Voltage Insulators, Online and Offline Techniques: A review
title_sort condition monitoring of outdoor high voltage insulators online and offline techniques a review
topic Condition monitoring
outdoor insulators
flashover voltage
surface leakage current
transmission
url https://journals.nust.edu.pk/index.php/njes/article/view/627
work_keys_str_mv AT haseebfaisal conditionmonitoringofoutdoorhighvoltageinsulatorsonlineandofflinetechniquesareview
AT arshadali conditionmonitoringofoutdoorhighvoltageinsulatorsonlineandofflinetechniquesareview
AT muhammadriaz conditionmonitoringofoutdoorhighvoltageinsulatorsonlineandofflinetechniquesareview