ON THE NEED TO INCREASE THE RELIABILITY OF LINEAR INSULATORS FOR DISTRIBUTION NETWORKS 10-20 KV

Introduction. In Ukraine high voltage overhead distribution lines (OL) of class 6 and 10 kV are the most extended. Their total length exceeds 280,000 km. More than 95% of the lines are made on line supports from reinforced concrete racks. On all poles of the overhead line, pin insulators are install...

Full description

Bibliographic Details
Main Authors: Yu. N. Shumilov, V. G. Santotsky, E. D. Shumilova
Format: Article
Language:English
Published: National Technical University "Kharkiv Polytechnic Institute" 2018-02-01
Series:Electrical engineering & Electromechanics
Subjects:
Online Access:http://eie.khpi.edu.ua/article/view/2074-272X.2018.1.10/117737
_version_ 1819040164818714624
author Yu. N. Shumilov
V. G. Santotsky
E. D. Shumilova
author_facet Yu. N. Shumilov
V. G. Santotsky
E. D. Shumilova
author_sort Yu. N. Shumilov
collection DOAJ
description Introduction. In Ukraine high voltage overhead distribution lines (OL) of class 6 and 10 kV are the most extended. Their total length exceeds 280,000 km. More than 95% of the lines are made on line supports from reinforced concrete racks. On all poles of the overhead line, pin insulators are installed. According to the data of operation experience, up to 60-70% of single-phase earth (SPE) faults due to «insulation» occurs on VL supports due to damage to line pin insulators, mainly during the thunderstorm period. Problem. Insufficient reliability of pin insulators leads to interruptions in power supply, accidents on the line, accidents in the area of reinforced concrete poles, where in the case of insulator damages, a long process of SPE occurs. Goal. The purpose of the work is to select the design and develop requirements for new linear insulators of 10-20 kV overhead lines that provide high resistance to lightning overvoltages with direct and inductive effects of lightning. Methodology. The research methodology consists in analyzing operational experience, calculating insulator parameters and laboratory tests. Results. Using statistical data on lightning parameters and data on mechanical loads on insulators, the main dimensions of line post insulators have been determined that will ensure their reliable operation under conditions of intense thunderstorm activity and extreme ice and wind loads. Conclusions. The main technical requirements for line post insulators for 10-20 kV distribution lines were formulated. On the 10 kV OL located in areas with increased thunderstorm activity it is recommended to use line post insulators instead of pin-type ones. On the OL-20 kV it is recommended to use only line post insulators. The use of high-lightning-resistant line post insulators on OL-10-20 kV will significantly increase the electrical safety and reliability of power supply to consumers. Increased by 2-3 times the cost of line post insulators in comparison with those used will be compensated for by the effects of reducing the number of collapsible supports, damage from under-supply of electricity, labor costs during transportation and restoration of destroyed supports, the moral side of reducing accidents in case of electric shock in the emergency zone. The insulators offered for OL-10-20 kV can be used for fixing both bare and protected wires. The exclusion from the design of the weakest elements – polyethylene caps and metal pins will increase the reliability of the power isolation unit.
first_indexed 2024-12-21T09:04:45Z
format Article
id doaj.art-32cfc3f8814e499cbdb66b939cecbeb6
institution Directory Open Access Journal
issn 2074-272X
2309-3404
language English
last_indexed 2024-12-21T09:04:45Z
publishDate 2018-02-01
publisher National Technical University "Kharkiv Polytechnic Institute"
record_format Article
series Electrical engineering & Electromechanics
spelling doaj.art-32cfc3f8814e499cbdb66b939cecbeb62022-12-21T19:09:23ZengNational Technical University "Kharkiv Polytechnic Institute"Electrical engineering & Electromechanics2074-272X2309-34042018-02-011626510.20998/2074-272X.2018.1.10ON THE NEED TO INCREASE THE RELIABILITY OF LINEAR INSULATORS FOR DISTRIBUTION NETWORKS 10-20 KVYu. N. Shumilov0V. G. Santotsky1E. D. Shumilova2 PSC «Slavyansk High Voltage Insulators Works» Research & Design Center for development of the IPS of Ukraine Donbass State Pedagogical University Introduction. In Ukraine high voltage overhead distribution lines (OL) of class 6 and 10 kV are the most extended. Their total length exceeds 280,000 km. More than 95% of the lines are made on line supports from reinforced concrete racks. On all poles of the overhead line, pin insulators are installed. According to the data of operation experience, up to 60-70% of single-phase earth (SPE) faults due to «insulation» occurs on VL supports due to damage to line pin insulators, mainly during the thunderstorm period. Problem. Insufficient reliability of pin insulators leads to interruptions in power supply, accidents on the line, accidents in the area of reinforced concrete poles, where in the case of insulator damages, a long process of SPE occurs. Goal. The purpose of the work is to select the design and develop requirements for new linear insulators of 10-20 kV overhead lines that provide high resistance to lightning overvoltages with direct and inductive effects of lightning. Methodology. The research methodology consists in analyzing operational experience, calculating insulator parameters and laboratory tests. Results. Using statistical data on lightning parameters and data on mechanical loads on insulators, the main dimensions of line post insulators have been determined that will ensure their reliable operation under conditions of intense thunderstorm activity and extreme ice and wind loads. Conclusions. The main technical requirements for line post insulators for 10-20 kV distribution lines were formulated. On the 10 kV OL located in areas with increased thunderstorm activity it is recommended to use line post insulators instead of pin-type ones. On the OL-20 kV it is recommended to use only line post insulators. The use of high-lightning-resistant line post insulators on OL-10-20 kV will significantly increase the electrical safety and reliability of power supply to consumers. Increased by 2-3 times the cost of line post insulators in comparison with those used will be compensated for by the effects of reducing the number of collapsible supports, damage from under-supply of electricity, labor costs during transportation and restoration of destroyed supports, the moral side of reducing accidents in case of electric shock in the emergency zone. The insulators offered for OL-10-20 kV can be used for fixing both bare and protected wires. The exclusion from the design of the weakest elements – polyethylene caps and metal pins will increase the reliability of the power isolation unit.http://eie.khpi.edu.ua/article/view/2074-272X.2018.1.10/117737overhead power linepin insulatorsline post insulatorslightning over voltageselectrical breakdownflashover of insulatorpower supply interruptionselectrical safetyreliability
spellingShingle Yu. N. Shumilov
V. G. Santotsky
E. D. Shumilova
ON THE NEED TO INCREASE THE RELIABILITY OF LINEAR INSULATORS FOR DISTRIBUTION NETWORKS 10-20 KV
Electrical engineering & Electromechanics
overhead power line
pin insulators
line post insulators
lightning over voltages
electrical breakdown
flashover of insulator
power supply interruptions
electrical safety
reliability
title ON THE NEED TO INCREASE THE RELIABILITY OF LINEAR INSULATORS FOR DISTRIBUTION NETWORKS 10-20 KV
title_full ON THE NEED TO INCREASE THE RELIABILITY OF LINEAR INSULATORS FOR DISTRIBUTION NETWORKS 10-20 KV
title_fullStr ON THE NEED TO INCREASE THE RELIABILITY OF LINEAR INSULATORS FOR DISTRIBUTION NETWORKS 10-20 KV
title_full_unstemmed ON THE NEED TO INCREASE THE RELIABILITY OF LINEAR INSULATORS FOR DISTRIBUTION NETWORKS 10-20 KV
title_short ON THE NEED TO INCREASE THE RELIABILITY OF LINEAR INSULATORS FOR DISTRIBUTION NETWORKS 10-20 KV
title_sort on the need to increase the reliability of linear insulators for distribution networks 10 20 kv
topic overhead power line
pin insulators
line post insulators
lightning over voltages
electrical breakdown
flashover of insulator
power supply interruptions
electrical safety
reliability
url http://eie.khpi.edu.ua/article/view/2074-272X.2018.1.10/117737
work_keys_str_mv AT yunshumilov ontheneedtoincreasethereliabilityoflinearinsulatorsfordistributionnetworks1020kv
AT vgsantotsky ontheneedtoincreasethereliabilityoflinearinsulatorsfordistributionnetworks1020kv
AT edshumilova ontheneedtoincreasethereliabilityoflinearinsulatorsfordistributionnetworks1020kv