Improving the reliability of underwater gait analysis using wearable pressure and inertial sensors.

This work addresses the lack of reliable wearable methods to assess walking gaits in underwater environments by evaluating the lateral hydrodynamic pressure exerted on lower limbs. Sixteen healthy adults were outfitted with waterproof wearable inertial and pressure sensors. Gait analysis was conduct...

Full description

Bibliographic Details
Main Authors: Cecilia Monoli, Manuela Galli, Jeffrey A Tuhtan
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2024-01-01
Series:PLoS ONE
Online Access:https://doi.org/10.1371/journal.pone.0300100
_version_ 1797242803807322112
author Cecilia Monoli
Manuela Galli
Jeffrey A Tuhtan
author_facet Cecilia Monoli
Manuela Galli
Jeffrey A Tuhtan
author_sort Cecilia Monoli
collection DOAJ
description This work addresses the lack of reliable wearable methods to assess walking gaits in underwater environments by evaluating the lateral hydrodynamic pressure exerted on lower limbs. Sixteen healthy adults were outfitted with waterproof wearable inertial and pressure sensors. Gait analysis was conducted on land in a motion analysis laboratory using an optoelectronic system as reference, and subsequently underwater in a rehabilitation swimming pool. Differences between the normalized land and underwater gaits were evaluated using temporal gait parameters, knee joint angles and the total water pressure on the lower limbs. The proposed method was validated against the optoelectronic system on land; gait events were identified with low bias (0.01s) using Bland-Altman plots for the stride time, and an acceptable error was observed when estimating the knee angle (10.96° RMSE, Bland-Altman bias -2.94°). The kinematic differences between the land and underwater environments were quantified, where it was observed that the temporal parameters increased by more than a factor of two underwater (p<0.001). The subdivision of swing and stance phases remained consistent between land and water trials. A higher variability of the knee angle was observed in water (CV = 60.75%) as compared to land (CV = 31.02%). The intra-subject variability of the hydrodynamic pressure on the foot ([Formula: see text] = 39.65%) was found to be substantially lower than that of the knee angle (CVz = 67.69%). The major finding of this work is that the hydrodynamic pressure on the lower limbs may offer a new and more reliable parameter for underwater motion analysis as it provided a reduced intra-subject variability as compared to conventional gait parameters applied in land-based studies.
first_indexed 2024-04-24T18:45:02Z
format Article
id doaj.art-332e9dbeb8a144fd992d6749fcda6c68
institution Directory Open Access Journal
issn 1932-6203
language English
last_indexed 2024-04-24T18:45:02Z
publishDate 2024-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj.art-332e9dbeb8a144fd992d6749fcda6c682024-03-27T05:32:53ZengPublic Library of Science (PLoS)PLoS ONE1932-62032024-01-01193e030010010.1371/journal.pone.0300100Improving the reliability of underwater gait analysis using wearable pressure and inertial sensors.Cecilia MonoliManuela GalliJeffrey A TuhtanThis work addresses the lack of reliable wearable methods to assess walking gaits in underwater environments by evaluating the lateral hydrodynamic pressure exerted on lower limbs. Sixteen healthy adults were outfitted with waterproof wearable inertial and pressure sensors. Gait analysis was conducted on land in a motion analysis laboratory using an optoelectronic system as reference, and subsequently underwater in a rehabilitation swimming pool. Differences between the normalized land and underwater gaits were evaluated using temporal gait parameters, knee joint angles and the total water pressure on the lower limbs. The proposed method was validated against the optoelectronic system on land; gait events were identified with low bias (0.01s) using Bland-Altman plots for the stride time, and an acceptable error was observed when estimating the knee angle (10.96° RMSE, Bland-Altman bias -2.94°). The kinematic differences between the land and underwater environments were quantified, where it was observed that the temporal parameters increased by more than a factor of two underwater (p<0.001). The subdivision of swing and stance phases remained consistent between land and water trials. A higher variability of the knee angle was observed in water (CV = 60.75%) as compared to land (CV = 31.02%). The intra-subject variability of the hydrodynamic pressure on the foot ([Formula: see text] = 39.65%) was found to be substantially lower than that of the knee angle (CVz = 67.69%). The major finding of this work is that the hydrodynamic pressure on the lower limbs may offer a new and more reliable parameter for underwater motion analysis as it provided a reduced intra-subject variability as compared to conventional gait parameters applied in land-based studies.https://doi.org/10.1371/journal.pone.0300100
spellingShingle Cecilia Monoli
Manuela Galli
Jeffrey A Tuhtan
Improving the reliability of underwater gait analysis using wearable pressure and inertial sensors.
PLoS ONE
title Improving the reliability of underwater gait analysis using wearable pressure and inertial sensors.
title_full Improving the reliability of underwater gait analysis using wearable pressure and inertial sensors.
title_fullStr Improving the reliability of underwater gait analysis using wearable pressure and inertial sensors.
title_full_unstemmed Improving the reliability of underwater gait analysis using wearable pressure and inertial sensors.
title_short Improving the reliability of underwater gait analysis using wearable pressure and inertial sensors.
title_sort improving the reliability of underwater gait analysis using wearable pressure and inertial sensors
url https://doi.org/10.1371/journal.pone.0300100
work_keys_str_mv AT ceciliamonoli improvingthereliabilityofunderwatergaitanalysisusingwearablepressureandinertialsensors
AT manuelagalli improvingthereliabilityofunderwatergaitanalysisusingwearablepressureandinertialsensors
AT jeffreyatuhtan improvingthereliabilityofunderwatergaitanalysisusingwearablepressureandinertialsensors