Biomechanical evaluation of a new intramedullary nail compared with proximal femoral nail antirotation and InterTAN for the management of femoral intertrochanteric fractures

Purpose: Surgical treatment is the main treatment method for femoral intertrochanteric fractures (FIFs), however, there are lots of implant-related complications after surgery. Our team designed a new intramedullary nail (NIN) to manage such fractures. The purpose of this study was to introduce this...

Full description

Bibliographic Details
Main Authors: ChaoFeng Wang, Ning Duan, Zhong Li, Teng Ma, Kun Zhang, Qian Wang, Qiang Huang
Format: Article
Language:English
Published: Frontiers Media S.A. 2024-02-01
Series:Frontiers in Bioengineering and Biotechnology
Subjects:
Online Access:https://www.frontiersin.org/articles/10.3389/fbioe.2024.1353677/full
_version_ 1797299743368413184
author ChaoFeng Wang
Ning Duan
Zhong Li
Teng Ma
Kun Zhang
Qian Wang
Qiang Huang
author_facet ChaoFeng Wang
Ning Duan
Zhong Li
Teng Ma
Kun Zhang
Qian Wang
Qiang Huang
author_sort ChaoFeng Wang
collection DOAJ
description Purpose: Surgical treatment is the main treatment method for femoral intertrochanteric fractures (FIFs), however, there are lots of implant-related complications after surgery. Our team designed a new intramedullary nail (NIN) to manage such fractures. The purpose of this study was to introduce this new implant and compare it with proximal femoral nail antirotation (PFNA) and InterTAN for treating FIFs.Methods: An AO/OTA 31-A1.3 FIF model was built and three fixation models were created via finite element method, comprising PFNA, InterTAN, and the NIN. Vertical, anteroposterior (A-P) bending, and torsional loads were simulated and applied to the three fixation models. Displacement and stress distribution were monitored. In order to compare PFNA and the NIN deeply, finite element testing was repeated for five times in vertical load case.Results: The finite element analysis (FEA) data indicated that the NIN possessed the most outstanding mechanical properties among the three fixation models. The NIN model had lower maximal stress at implants compared to PFNA and InterTAN models under three load conditions. The trend of maximal stress at bones was similar to that of maximal stress at implants. Besides, the NIN model showed smaller maximal displacement compared with PFNA and InterTAN models under vertical, A-P bending, and torsional load cases. The trend for maximal displacement of fracture surface (MDFS) was almost identical with that of maximal displacement. In addition, there was significant difference between the PFNA and NIN groups in vertical load case (p < 0.05).Conclusion: Compared with PFNA and InterTAN, the NIN displayed the best mechanical properties for managing FIFs, including the lowest von Mises stress at implants and bones, and the smallest maximal displacement and MDFS under vertical, A-P bending, and torsional load cases. Therefore, this study might provide a new choice for patients with FIFs.
first_indexed 2024-03-07T22:55:06Z
format Article
id doaj.art-3374684c13ad45d88831168d35e10a46
institution Directory Open Access Journal
issn 2296-4185
language English
last_indexed 2024-03-07T22:55:06Z
publishDate 2024-02-01
publisher Frontiers Media S.A.
record_format Article
series Frontiers in Bioengineering and Biotechnology
spelling doaj.art-3374684c13ad45d88831168d35e10a462024-02-23T04:47:45ZengFrontiers Media S.A.Frontiers in Bioengineering and Biotechnology2296-41852024-02-011210.3389/fbioe.2024.13536771353677Biomechanical evaluation of a new intramedullary nail compared with proximal femoral nail antirotation and InterTAN for the management of femoral intertrochanteric fracturesChaoFeng WangNing DuanZhong LiTeng MaKun ZhangQian WangQiang HuangPurpose: Surgical treatment is the main treatment method for femoral intertrochanteric fractures (FIFs), however, there are lots of implant-related complications after surgery. Our team designed a new intramedullary nail (NIN) to manage such fractures. The purpose of this study was to introduce this new implant and compare it with proximal femoral nail antirotation (PFNA) and InterTAN for treating FIFs.Methods: An AO/OTA 31-A1.3 FIF model was built and three fixation models were created via finite element method, comprising PFNA, InterTAN, and the NIN. Vertical, anteroposterior (A-P) bending, and torsional loads were simulated and applied to the three fixation models. Displacement and stress distribution were monitored. In order to compare PFNA and the NIN deeply, finite element testing was repeated for five times in vertical load case.Results: The finite element analysis (FEA) data indicated that the NIN possessed the most outstanding mechanical properties among the three fixation models. The NIN model had lower maximal stress at implants compared to PFNA and InterTAN models under three load conditions. The trend of maximal stress at bones was similar to that of maximal stress at implants. Besides, the NIN model showed smaller maximal displacement compared with PFNA and InterTAN models under vertical, A-P bending, and torsional load cases. The trend for maximal displacement of fracture surface (MDFS) was almost identical with that of maximal displacement. In addition, there was significant difference between the PFNA and NIN groups in vertical load case (p < 0.05).Conclusion: Compared with PFNA and InterTAN, the NIN displayed the best mechanical properties for managing FIFs, including the lowest von Mises stress at implants and bones, and the smallest maximal displacement and MDFS under vertical, A-P bending, and torsional load cases. Therefore, this study might provide a new choice for patients with FIFs.https://www.frontiersin.org/articles/10.3389/fbioe.2024.1353677/fullmechanicalfemurintertrochanteric fracturestabilityfinite element methodimplant
spellingShingle ChaoFeng Wang
Ning Duan
Zhong Li
Teng Ma
Kun Zhang
Qian Wang
Qiang Huang
Biomechanical evaluation of a new intramedullary nail compared with proximal femoral nail antirotation and InterTAN for the management of femoral intertrochanteric fractures
Frontiers in Bioengineering and Biotechnology
mechanical
femur
intertrochanteric fracture
stability
finite element method
implant
title Biomechanical evaluation of a new intramedullary nail compared with proximal femoral nail antirotation and InterTAN for the management of femoral intertrochanteric fractures
title_full Biomechanical evaluation of a new intramedullary nail compared with proximal femoral nail antirotation and InterTAN for the management of femoral intertrochanteric fractures
title_fullStr Biomechanical evaluation of a new intramedullary nail compared with proximal femoral nail antirotation and InterTAN for the management of femoral intertrochanteric fractures
title_full_unstemmed Biomechanical evaluation of a new intramedullary nail compared with proximal femoral nail antirotation and InterTAN for the management of femoral intertrochanteric fractures
title_short Biomechanical evaluation of a new intramedullary nail compared with proximal femoral nail antirotation and InterTAN for the management of femoral intertrochanteric fractures
title_sort biomechanical evaluation of a new intramedullary nail compared with proximal femoral nail antirotation and intertan for the management of femoral intertrochanteric fractures
topic mechanical
femur
intertrochanteric fracture
stability
finite element method
implant
url https://www.frontiersin.org/articles/10.3389/fbioe.2024.1353677/full
work_keys_str_mv AT chaofengwang biomechanicalevaluationofanewintramedullarynailcomparedwithproximalfemoralnailantirotationandintertanforthemanagementoffemoralintertrochantericfractures
AT ningduan biomechanicalevaluationofanewintramedullarynailcomparedwithproximalfemoralnailantirotationandintertanforthemanagementoffemoralintertrochantericfractures
AT zhongli biomechanicalevaluationofanewintramedullarynailcomparedwithproximalfemoralnailantirotationandintertanforthemanagementoffemoralintertrochantericfractures
AT tengma biomechanicalevaluationofanewintramedullarynailcomparedwithproximalfemoralnailantirotationandintertanforthemanagementoffemoralintertrochantericfractures
AT kunzhang biomechanicalevaluationofanewintramedullarynailcomparedwithproximalfemoralnailantirotationandintertanforthemanagementoffemoralintertrochantericfractures
AT qianwang biomechanicalevaluationofanewintramedullarynailcomparedwithproximalfemoralnailantirotationandintertanforthemanagementoffemoralintertrochantericfractures
AT qianghuang biomechanicalevaluationofanewintramedullarynailcomparedwithproximalfemoralnailantirotationandintertanforthemanagementoffemoralintertrochantericfractures