Effect of FRP on the Energy Absorbed by Steel Shear Walls with Openings
It’s for more than three decades that Steel Shear Walls are being used as lateral load resisting system. Definitely,the actual behavior of steel shear walls can be assessed using experimental results. However, solve many of phenomenon like this one should be done using mathematical and theoretical m...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | fas |
Published: |
Iranian Society of Structrual Engineering (ISSE)
2015-06-01
|
Series: | Journal of Structural and Construction Engineering |
Subjects: | |
Online Access: | https://www.jsce.ir/article_38615_0847a8cb34dde42b60e0b91b05e282b8.pdf |
_version_ | 1818897395430195200 |
---|---|
author | Mojtaba Ghasemzadeh Mansour Ghalehnovi Abdolhamid Bahrpeyma |
author_facet | Mojtaba Ghasemzadeh Mansour Ghalehnovi Abdolhamid Bahrpeyma |
author_sort | Mojtaba Ghasemzadeh |
collection | DOAJ |
description | It’s for more than three decades that Steel Shear Walls are being used as lateral load resisting system. Definitely,the actual behavior of steel shear walls can be assessed using experimental results. However, solve many of phenomenon like this one should be done using mathematical and theoretical methods due to their special characteristics such as high expenses, lack of laboratory facilities and time limitations. In this study, the behavior of steel plate shear walls with openings in a one-story frame were evaluated and compared in various conditions. For this purpose, different values for the opening in shear wall was considered and exposed to lateral displacement in ABAQUS as a comprehensive finite element software. Then, the impact of FRP arrangement on shear wall was evaluated to represent the structural behavior under various conditions. Result shows that, use of FRP sheets as parallel layers on both sides of shear wall has the best response on energy absorption, so that performance of the model was better than shear wall fully covered with FRP. |
first_indexed | 2024-12-19T19:15:30Z |
format | Article |
id | doaj.art-33872d22bbd442ccb78f6b4f7f5fef1f |
institution | Directory Open Access Journal |
issn | 2476-3977 2538-2616 |
language | fas |
last_indexed | 2024-12-19T19:15:30Z |
publishDate | 2015-06-01 |
publisher | Iranian Society of Structrual Engineering (ISSE) |
record_format | Article |
series | Journal of Structural and Construction Engineering |
spelling | doaj.art-33872d22bbd442ccb78f6b4f7f5fef1f2022-12-21T20:09:08ZfasIranian Society of Structrual Engineering (ISSE)Journal of Structural and Construction Engineering2476-39772538-26162015-06-0121344538615Effect of FRP on the Energy Absorbed by Steel Shear Walls with OpeningsMojtaba Ghasemzadeh0Mansour Ghalehnovi1Abdolhamid Bahrpeyma2MSc student in structural Engineering, Department of Civil Engineering, Islamic Azad University of ZahedanAssociate Professor, Department of Civil Engineering, Ferdowsi University of MashhadAssociate Professor, Department of Civil Engineering, University of Sistan and BaluchestanIt’s for more than three decades that Steel Shear Walls are being used as lateral load resisting system. Definitely,the actual behavior of steel shear walls can be assessed using experimental results. However, solve many of phenomenon like this one should be done using mathematical and theoretical methods due to their special characteristics such as high expenses, lack of laboratory facilities and time limitations. In this study, the behavior of steel plate shear walls with openings in a one-story frame were evaluated and compared in various conditions. For this purpose, different values for the opening in shear wall was considered and exposed to lateral displacement in ABAQUS as a comprehensive finite element software. Then, the impact of FRP arrangement on shear wall was evaluated to represent the structural behavior under various conditions. Result shows that, use of FRP sheets as parallel layers on both sides of shear wall has the best response on energy absorption, so that performance of the model was better than shear wall fully covered with FRP.https://www.jsce.ir/article_38615_0847a8cb34dde42b60e0b91b05e282b8.pdfsteel plate shear wallfrp reinforceopening in shear wallenergy absorption |
spellingShingle | Mojtaba Ghasemzadeh Mansour Ghalehnovi Abdolhamid Bahrpeyma Effect of FRP on the Energy Absorbed by Steel Shear Walls with Openings Journal of Structural and Construction Engineering steel plate shear wall frp reinforce opening in shear wall energy absorption |
title | Effect of FRP on the Energy Absorbed by Steel Shear Walls with Openings |
title_full | Effect of FRP on the Energy Absorbed by Steel Shear Walls with Openings |
title_fullStr | Effect of FRP on the Energy Absorbed by Steel Shear Walls with Openings |
title_full_unstemmed | Effect of FRP on the Energy Absorbed by Steel Shear Walls with Openings |
title_short | Effect of FRP on the Energy Absorbed by Steel Shear Walls with Openings |
title_sort | effect of frp on the energy absorbed by steel shear walls with openings |
topic | steel plate shear wall frp reinforce opening in shear wall energy absorption |
url | https://www.jsce.ir/article_38615_0847a8cb34dde42b60e0b91b05e282b8.pdf |
work_keys_str_mv | AT mojtabaghasemzadeh effectoffrpontheenergyabsorbedbysteelshearwallswithopenings AT mansourghalehnovi effectoffrpontheenergyabsorbedbysteelshearwallswithopenings AT abdolhamidbahrpeyma effectoffrpontheenergyabsorbedbysteelshearwallswithopenings |