Open-circuit fault diagnosis in three-phase induction motor using model-based technique
The presence of an open-circuit fault subjects a three-phase induction motor to severely unbalanced voltages that may damage the stator windings consecutively causing total shutdown of systems. Unplanned downtime is very costly. Therefore, fault diagnosis is essential for making a predictive plan fo...
Main Authors: | Raya A.K. Aswad, Bassim M.H. Jassim |
---|---|
Format: | Article |
Language: | English |
Published: |
Polish Academy of Sciences
2020-11-01
|
Series: | Archives of Electrical Engineering |
Subjects: | |
Online Access: | https://journals.pan.pl/Content/117665/PDF/art06.pdf |
Similar Items
-
Impact of Induction Motor Faults on the Basic Parameters' Values
by: Raya A. K. Aswad, et al.
Published: (2020-12-01) -
Hybrid Model-Based Fuzzy Logic Diagnostic System for Stator Faults in Three-Phase Cage Induction Motors
by: Raya A. K. Aswad, et al.
Published: (2023-01-01) -
Convolutional Neural Network-Based Stator Current Data-Driven Incipient Stator Fault Diagnosis of Inverter-Fed Induction Motor
by: Maciej Skowron, et al.
Published: (2020-03-01) -
A Survey of Broken Rotor Bar Fault Diagnostic Methods of Induction Motor
by: Asad Bilal, et al.
Published: (2018-12-01) -
Application of Frequency Response Analysis Method to Detect Short-Circuit Faults in Three-Phase Induction Motors
by: Salem Mgammal Al-Ameri, et al.
Published: (2022-02-01)