Energy Saving Thermal Management of Space Remote Sensor and Validation
An energy-efficient thermal control management method for space remote sensors using optical, mechanical, electrical, and thermal integration is proposed. The satellite power resources are insufficient, so an energy-efficient loop heat pipe (LHP) is designed for six intermittently operating detector...
Main Authors: | Pan Lu, Teng Gao, Quanwang Chen, Xiaohan Ren |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2023-01-01
|
Series: | Energies |
Subjects: | |
Online Access: | https://www.mdpi.com/1996-1073/16/2/864 |
Similar Items
-
Loop heat pipe for thermal conditions supplying systems for elements of radio electronic equipment
by: Khayrnasov S. М.
Published: (2010-06-01) -
Advanced loop heat pipe application for cooling high power LED lights
by: Igors Ušakovs, et al.
Published: (2024-05-01) -
Polyethersulfone wick and metal wick based loop heat pipe for LED street light thermal management
by: Xianfeng Hu, et al.
Published: (2023-09-01) -
Experimental Study on Thermal Performance of a Loop Heat Pipe with Different Working Wick Materials
by: Kyaw Zin Htoo, et al.
Published: (2021-04-01) -
Experimental thermal characterization of the in-wheel electric motor with loop heat pipe thermal management system
by: Igors Ušakovs, et al.
Published: (2023-07-01)