Analysis of transmission line modeling routines by using offsets measured least squares regression ant lion optimizer in ORPD and ELD problems

This paper proposed an offset measured least regression based ALO to solve ORPD and ELD problems of IEEE 57 bus system designed with different transmission line models. These two problems are highly non-linear and non-convex defiance optimization of problem. The solution of ALO depends on exploratio...

Full description

Bibliographic Details
Main Authors: G. Veera Bhadra Chary, K. Mercy Rosalina
Format: Article
Language:English
Published: Elsevier 2023-03-01
Series:Heliyon
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2405844023005947
_version_ 1797851968488603648
author G. Veera Bhadra Chary
K. Mercy Rosalina
author_facet G. Veera Bhadra Chary
K. Mercy Rosalina
author_sort G. Veera Bhadra Chary
collection DOAJ
description This paper proposed an offset measured least regression based ALO to solve ORPD and ELD problems of IEEE 57 bus system designed with different transmission line models. These two problems are highly non-linear and non-convex defiance optimization of problem. The solution of ALO depends on exploration and exploitation if the difference between local and global variables is large, therefore chance to miss the best optimal solution. The weighted elitism phase of the algorithm gives diversified results because exploration is more biased toward elite particles. Which is due to decreasing of random walk to achieve the convergence characteristics. The proposed LSR-EALO can balance both exploration and exploitation, which improves the solution of optimization problem. Simulation is performed with proposed method on different IEEE 57 bus power system models, such as the positive sequence, 3-Phase PI, and distributed CP transmission lines based power systems, and lumped PI lines based low voltage hardware model (LVHM). In this paper, the ORPD problem was used to describe control variables like generator voltage, tap changers of transformers, and switching of capacitor banks subjected to power loss minimization function. Also, described voltage deviation and voltage stability index. Similarly, the ELD was described the active power allocation among generators to meet the sum of load demand and losses in the systems at minimum fuel cost function. And in depth analysis of the optimization results shows accuracy of control variables in ORPD and ELD problems. Also, the effectiveness of proposed method was also verified by comparing results with other meta heuristic algorithms.
first_indexed 2024-04-09T19:25:20Z
format Article
id doaj.art-346c0be8a0af4933ab27ab79d1e8f8fe
institution Directory Open Access Journal
issn 2405-8440
language English
last_indexed 2024-04-09T19:25:20Z
publishDate 2023-03-01
publisher Elsevier
record_format Article
series Heliyon
spelling doaj.art-346c0be8a0af4933ab27ab79d1e8f8fe2023-04-05T08:15:28ZengElsevierHeliyon2405-84402023-03-0193e13387Analysis of transmission line modeling routines by using offsets measured least squares regression ant lion optimizer in ORPD and ELD problemsG. Veera Bhadra Chary0K. Mercy Rosalina1Corresponding author.; Department of Electrical and Electronics Engineering, VFSTR deemed to be University, Vadlamudi, Guntur, A.P, 522213, IndiaDepartment of Electrical and Electronics Engineering, VFSTR deemed to be University, Vadlamudi, Guntur, A.P, 522213, IndiaThis paper proposed an offset measured least regression based ALO to solve ORPD and ELD problems of IEEE 57 bus system designed with different transmission line models. These two problems are highly non-linear and non-convex defiance optimization of problem. The solution of ALO depends on exploration and exploitation if the difference between local and global variables is large, therefore chance to miss the best optimal solution. The weighted elitism phase of the algorithm gives diversified results because exploration is more biased toward elite particles. Which is due to decreasing of random walk to achieve the convergence characteristics. The proposed LSR-EALO can balance both exploration and exploitation, which improves the solution of optimization problem. Simulation is performed with proposed method on different IEEE 57 bus power system models, such as the positive sequence, 3-Phase PI, and distributed CP transmission lines based power systems, and lumped PI lines based low voltage hardware model (LVHM). In this paper, the ORPD problem was used to describe control variables like generator voltage, tap changers of transformers, and switching of capacitor banks subjected to power loss minimization function. Also, described voltage deviation and voltage stability index. Similarly, the ELD was described the active power allocation among generators to meet the sum of load demand and losses in the systems at minimum fuel cost function. And in depth analysis of the optimization results shows accuracy of control variables in ORPD and ELD problems. Also, the effectiveness of proposed method was also verified by comparing results with other meta heuristic algorithms.http://www.sciencedirect.com/science/article/pii/S2405844023005947Ant lion optimizer (ALO)CPELDIEEE 57 busLSR-EALOLow voltage hardware model
spellingShingle G. Veera Bhadra Chary
K. Mercy Rosalina
Analysis of transmission line modeling routines by using offsets measured least squares regression ant lion optimizer in ORPD and ELD problems
Heliyon
Ant lion optimizer (ALO)
CP
ELD
IEEE 57 bus
LSR-EALO
Low voltage hardware model
title Analysis of transmission line modeling routines by using offsets measured least squares regression ant lion optimizer in ORPD and ELD problems
title_full Analysis of transmission line modeling routines by using offsets measured least squares regression ant lion optimizer in ORPD and ELD problems
title_fullStr Analysis of transmission line modeling routines by using offsets measured least squares regression ant lion optimizer in ORPD and ELD problems
title_full_unstemmed Analysis of transmission line modeling routines by using offsets measured least squares regression ant lion optimizer in ORPD and ELD problems
title_short Analysis of transmission line modeling routines by using offsets measured least squares regression ant lion optimizer in ORPD and ELD problems
title_sort analysis of transmission line modeling routines by using offsets measured least squares regression ant lion optimizer in orpd and eld problems
topic Ant lion optimizer (ALO)
CP
ELD
IEEE 57 bus
LSR-EALO
Low voltage hardware model
url http://www.sciencedirect.com/science/article/pii/S2405844023005947
work_keys_str_mv AT gveerabhadrachary analysisoftransmissionlinemodelingroutinesbyusingoffsetsmeasuredleastsquaresregressionantlionoptimizerinorpdandeldproblems
AT kmercyrosalina analysisoftransmissionlinemodelingroutinesbyusingoffsetsmeasuredleastsquaresregressionantlionoptimizerinorpdandeldproblems