Psychometric properties of the Greek version of the NEI-VFQ 25

<p>Abstract</p> <p>Background</p> <p>To evaluate the reliability and construct validity of a Greek version of the NEI-VFQ-25 in patients with chronic ophthalmic diseases.</p> <p>Methods</p> <p>We developed the Greek version of the instrument usin...

Full description

Bibliographic Details
Main Authors: Tsirouki Theodora, Fanariotis Michael, Katsanos Andreas, Labiris Georgios, Pefkianaki Maria, Chatzoulis Dimitrios, Tsironi Evangelia
Format: Article
Language:English
Published: BMC 2008-03-01
Series:BMC Ophthalmology
Online Access:http://www.biomedcentral.com/1471-2415/8/4
_version_ 1819177245891100672
author Tsirouki Theodora
Fanariotis Michael
Katsanos Andreas
Labiris Georgios
Pefkianaki Maria
Chatzoulis Dimitrios
Tsironi Evangelia
author_facet Tsirouki Theodora
Fanariotis Michael
Katsanos Andreas
Labiris Georgios
Pefkianaki Maria
Chatzoulis Dimitrios
Tsironi Evangelia
author_sort Tsirouki Theodora
collection DOAJ
description <p>Abstract</p> <p>Background</p> <p>To evaluate the reliability and construct validity of a Greek version of the NEI-VFQ-25 in patients with chronic ophthalmic diseases.</p> <p>Methods</p> <p>We developed the Greek version of the instrument using forward and backward translation. One hundred-eighty-six patients responded to the questionnaire. To examine reliability, Cronbach's alpha for each subscale was used as an index of internal consistency. Test-retest reliability was evaluated with intraclass correlation coefficients. Regarding construct validity, both convergent and discriminant validities were calculated by means of multi-trait analysis. Rasch analysis was used to estimate the visual ability required by each item for a particular response, and each patient's visual ability. Correspondingly, instrument validity was evaluated by estimating the distribution of residuals for item and subject measures.</p> <p>Results</p> <p>Four patient groups were studied, each including participants with a single cause of visual impairment. Group 1 consisted of 84 glaucoma subjects. Group 2 included 30 subjects with age-related macular degeneration (ARMD); group 3 included 25 subjects with dry-eye syndrome, whereas group 4 included 18 cataract patients. Twenty-nine healthy individuals comprised the control group. NEI-VFQ scores (mean ± SD) for the glaucoma, ARMD, dry-eye, cataract and control groups were: 76.9 ± 20.2, 70.9 ± 20.2, 81.6 ± 16.5, 73.5 ± 24.0 and 93.7 ± 8.9 respectively. Item analysis revealed no significant data skewing. Cronbach's alpha ranged from 0.678 to 0.926, with most subscales having high internal consistency. Intraclass correlation coefficient ranged from 0.717 to 0.910 for all subscales. All items passed the convergent and discriminant validity tests. Strong correlations were detected between visual acuity and "general vision", "distant activities" and "near activities" subscales. Significant correlations were also detected between visual field deficits and the "peripheral vision" and "general vision" subscales. Rasch analysis revealed potential weaknesses of the instrument that are associated with the assumptions of the model itself. Specifically, low precision of the "agreement" items was detected in the estimation of visual ability. Twenty-three percent of the subjects had fit statistics that fell outside the tolerance box.</p> <p>Conclusion</p> <p>Although traditional validation methods indicated that the Greek version of the NEI-VFQ-25 is a valid and reliable instrument for VS-QoL assessment, Rasch analysis detected significant misfits to the model, especially of the "agreement" items. This means that results of the corresponding subscales should be interpreted with extreme caution.</p>
first_indexed 2024-12-22T21:23:36Z
format Article
id doaj.art-349265f2536a4ccea02827981f783e72
institution Directory Open Access Journal
issn 1471-2415
language English
last_indexed 2024-12-22T21:23:36Z
publishDate 2008-03-01
publisher BMC
record_format Article
series BMC Ophthalmology
spelling doaj.art-349265f2536a4ccea02827981f783e722022-12-21T18:12:06ZengBMCBMC Ophthalmology1471-24152008-03-0181410.1186/1471-2415-8-4Psychometric properties of the Greek version of the NEI-VFQ 25Tsirouki TheodoraFanariotis MichaelKatsanos AndreasLabiris GeorgiosPefkianaki MariaChatzoulis DimitriosTsironi Evangelia<p>Abstract</p> <p>Background</p> <p>To evaluate the reliability and construct validity of a Greek version of the NEI-VFQ-25 in patients with chronic ophthalmic diseases.</p> <p>Methods</p> <p>We developed the Greek version of the instrument using forward and backward translation. One hundred-eighty-six patients responded to the questionnaire. To examine reliability, Cronbach's alpha for each subscale was used as an index of internal consistency. Test-retest reliability was evaluated with intraclass correlation coefficients. Regarding construct validity, both convergent and discriminant validities were calculated by means of multi-trait analysis. Rasch analysis was used to estimate the visual ability required by each item for a particular response, and each patient's visual ability. Correspondingly, instrument validity was evaluated by estimating the distribution of residuals for item and subject measures.</p> <p>Results</p> <p>Four patient groups were studied, each including participants with a single cause of visual impairment. Group 1 consisted of 84 glaucoma subjects. Group 2 included 30 subjects with age-related macular degeneration (ARMD); group 3 included 25 subjects with dry-eye syndrome, whereas group 4 included 18 cataract patients. Twenty-nine healthy individuals comprised the control group. NEI-VFQ scores (mean ± SD) for the glaucoma, ARMD, dry-eye, cataract and control groups were: 76.9 ± 20.2, 70.9 ± 20.2, 81.6 ± 16.5, 73.5 ± 24.0 and 93.7 ± 8.9 respectively. Item analysis revealed no significant data skewing. Cronbach's alpha ranged from 0.678 to 0.926, with most subscales having high internal consistency. Intraclass correlation coefficient ranged from 0.717 to 0.910 for all subscales. All items passed the convergent and discriminant validity tests. Strong correlations were detected between visual acuity and "general vision", "distant activities" and "near activities" subscales. Significant correlations were also detected between visual field deficits and the "peripheral vision" and "general vision" subscales. Rasch analysis revealed potential weaknesses of the instrument that are associated with the assumptions of the model itself. Specifically, low precision of the "agreement" items was detected in the estimation of visual ability. Twenty-three percent of the subjects had fit statistics that fell outside the tolerance box.</p> <p>Conclusion</p> <p>Although traditional validation methods indicated that the Greek version of the NEI-VFQ-25 is a valid and reliable instrument for VS-QoL assessment, Rasch analysis detected significant misfits to the model, especially of the "agreement" items. This means that results of the corresponding subscales should be interpreted with extreme caution.</p>http://www.biomedcentral.com/1471-2415/8/4
spellingShingle Tsirouki Theodora
Fanariotis Michael
Katsanos Andreas
Labiris Georgios
Pefkianaki Maria
Chatzoulis Dimitrios
Tsironi Evangelia
Psychometric properties of the Greek version of the NEI-VFQ 25
BMC Ophthalmology
title Psychometric properties of the Greek version of the NEI-VFQ 25
title_full Psychometric properties of the Greek version of the NEI-VFQ 25
title_fullStr Psychometric properties of the Greek version of the NEI-VFQ 25
title_full_unstemmed Psychometric properties of the Greek version of the NEI-VFQ 25
title_short Psychometric properties of the Greek version of the NEI-VFQ 25
title_sort psychometric properties of the greek version of the nei vfq 25
url http://www.biomedcentral.com/1471-2415/8/4
work_keys_str_mv AT tsiroukitheodora psychometricpropertiesofthegreekversionoftheneivfq25
AT fanariotismichael psychometricpropertiesofthegreekversionoftheneivfq25
AT katsanosandreas psychometricpropertiesofthegreekversionoftheneivfq25
AT labirisgeorgios psychometricpropertiesofthegreekversionoftheneivfq25
AT pefkianakimaria psychometricpropertiesofthegreekversionoftheneivfq25
AT chatzoulisdimitrios psychometricpropertiesofthegreekversionoftheneivfq25
AT tsironievangelia psychometricpropertiesofthegreekversionoftheneivfq25