Comparison of Ziemer FEMTO LDV “Classic” and “Crystal Line” femtosecond laser flap quality by Fourier-domain optical coherence tomography

<b>AIM:</b> To compare the regularity and accuracy of laser <i>in situ</i> keratomileusis (LASIK) flaps created by the Ziemer FEMTO LDV “Classic” (Ziemer “Classic”) and Ziemer FEMTO LDV Crystal Line femtosecond laser (Ziemer Crystal Line).<b>METHODS:</b>Fourier-do...

Full description

Bibliographic Details
Main Authors: Jing Zhang, Yue-Hua Zhou, Lei Tian, Chang-Bin Zhai
Format: Article
Language:English
Published: Press of International Journal of Ophthalmology (IJO PRESS) 2013-10-01
Series:International Journal of Ophthalmology
Subjects:
Online Access:http://www.ijo.cn/en_publish/2013/5/20130512.pdf
_version_ 1818303305813590016
author Jing Zhang
Yue-Hua Zhou
Lei Tian
Chang-Bin Zhai
author_facet Jing Zhang
Yue-Hua Zhou
Lei Tian
Chang-Bin Zhai
author_sort Jing Zhang
collection DOAJ
description <b>AIM:</b> To compare the regularity and accuracy of laser <i>in situ</i> keratomileusis (LASIK) flaps created by the Ziemer FEMTO LDV “Classic” (Ziemer “Classic”) and Ziemer FEMTO LDV Crystal Line femtosecond laser (Ziemer Crystal Line).<b>METHODS:</b>Fourier-domain optical coherence tomography (RTVue OCT) was used tomeasure the morphology of 200 LASIK flaps of 100 consecutive patients created with the Ziemer Classic (100 flaps) or the Ziemer Crystal Line (100 flaps) at one week postoperatively. Flap thickness was evaluated at 36 specified measurement points on each flap. For all procedures with both lasers, the nominal flap thickness was 110µm.<b>RESULTS:</b>The mean flap thickness of the Ziemer Crystal Line group(102.49±2.68µm) was thinner than that of the Ziemer Classic group (107.65±5.09µm) (<i>P</i><0.01). Average thickness of all flaps was uniform within 4µm at all measurement points. The flaps in the Ziemer Crystal Line group were more regular than those in the Ziemer Classic group when measured from the center to the periphery. The maximum deviation from the nominal 110µm of 36 measurements was 8µm in the Ziemer Classic group, while in the Ziemer Crystal Line group it was 9µm. Within the 3 600 measurements on the 100 eyes, differences greater than 20µm were observed 0.14% in the Ziemer Classic group, and 0.04% in the Ziemer Crystal Line group.<b>CONCLUSION:</b>The flaps created with the Ziemer FEMTO LDV Crystal Linefemtosecond laser are more uniform and thinner than those created by the Ziemer FEMTO LDV Classic femtosecond laser.
first_indexed 2024-12-13T05:52:42Z
format Article
id doaj.art-34afa41fe12b4b849b647652bb79cdd4
institution Directory Open Access Journal
issn 2222-3959
2227-4898
language English
last_indexed 2024-12-13T05:52:42Z
publishDate 2013-10-01
publisher Press of International Journal of Ophthalmology (IJO PRESS)
record_format Article
series International Journal of Ophthalmology
spelling doaj.art-34afa41fe12b4b849b647652bb79cdd42022-12-21T23:57:30ZengPress of International Journal of Ophthalmology (IJO PRESS)International Journal of Ophthalmology2222-39592227-48982013-10-016561161710.3980/j.issn.2222-3959.2013.05.11Comparison of Ziemer FEMTO LDV “Classic” and “Crystal Line” femtosecond laser flap quality by Fourier-domain optical coherence tomographyJing ZhangYue-Hua ZhouLei TianChang-Bin Zhai<b>AIM:</b> To compare the regularity and accuracy of laser <i>in situ</i> keratomileusis (LASIK) flaps created by the Ziemer FEMTO LDV “Classic” (Ziemer “Classic”) and Ziemer FEMTO LDV Crystal Line femtosecond laser (Ziemer Crystal Line).<b>METHODS:</b>Fourier-domain optical coherence tomography (RTVue OCT) was used tomeasure the morphology of 200 LASIK flaps of 100 consecutive patients created with the Ziemer Classic (100 flaps) or the Ziemer Crystal Line (100 flaps) at one week postoperatively. Flap thickness was evaluated at 36 specified measurement points on each flap. For all procedures with both lasers, the nominal flap thickness was 110µm.<b>RESULTS:</b>The mean flap thickness of the Ziemer Crystal Line group(102.49±2.68µm) was thinner than that of the Ziemer Classic group (107.65±5.09µm) (<i>P</i><0.01). Average thickness of all flaps was uniform within 4µm at all measurement points. The flaps in the Ziemer Crystal Line group were more regular than those in the Ziemer Classic group when measured from the center to the periphery. The maximum deviation from the nominal 110µm of 36 measurements was 8µm in the Ziemer Classic group, while in the Ziemer Crystal Line group it was 9µm. Within the 3 600 measurements on the 100 eyes, differences greater than 20µm were observed 0.14% in the Ziemer Classic group, and 0.04% in the Ziemer Crystal Line group.<b>CONCLUSION:</b>The flaps created with the Ziemer FEMTO LDV Crystal Linefemtosecond laser are more uniform and thinner than those created by the Ziemer FEMTO LDV Classic femtosecond laser.http://www.ijo.cn/en_publish/2013/5/20130512.pdflaser in situ keratomileusisflap thicknessfemtosecond laserfourier-domain optical coherence tomography
spellingShingle Jing Zhang
Yue-Hua Zhou
Lei Tian
Chang-Bin Zhai
Comparison of Ziemer FEMTO LDV “Classic” and “Crystal Line” femtosecond laser flap quality by Fourier-domain optical coherence tomography
International Journal of Ophthalmology
laser in situ keratomileusis
flap thickness
femtosecond laser
fourier-domain optical coherence tomography
title Comparison of Ziemer FEMTO LDV “Classic” and “Crystal Line” femtosecond laser flap quality by Fourier-domain optical coherence tomography
title_full Comparison of Ziemer FEMTO LDV “Classic” and “Crystal Line” femtosecond laser flap quality by Fourier-domain optical coherence tomography
title_fullStr Comparison of Ziemer FEMTO LDV “Classic” and “Crystal Line” femtosecond laser flap quality by Fourier-domain optical coherence tomography
title_full_unstemmed Comparison of Ziemer FEMTO LDV “Classic” and “Crystal Line” femtosecond laser flap quality by Fourier-domain optical coherence tomography
title_short Comparison of Ziemer FEMTO LDV “Classic” and “Crystal Line” femtosecond laser flap quality by Fourier-domain optical coherence tomography
title_sort comparison of ziemer femto ldv classic and crystal line femtosecond laser flap quality by fourier domain optical coherence tomography
topic laser in situ keratomileusis
flap thickness
femtosecond laser
fourier-domain optical coherence tomography
url http://www.ijo.cn/en_publish/2013/5/20130512.pdf
work_keys_str_mv AT jingzhang comparisonofziemerfemtoldvclassicandcrystallinefemtosecondlaserflapqualitybyfourierdomainopticalcoherencetomography
AT yuehuazhou comparisonofziemerfemtoldvclassicandcrystallinefemtosecondlaserflapqualitybyfourierdomainopticalcoherencetomography
AT leitian comparisonofziemerfemtoldvclassicandcrystallinefemtosecondlaserflapqualitybyfourierdomainopticalcoherencetomography
AT changbinzhai comparisonofziemerfemtoldvclassicandcrystallinefemtosecondlaserflapqualitybyfourierdomainopticalcoherencetomography