Finite Element Analysis of the Mechanical Performance of Non-Restorable Crownless Primary Molars Restored with Intracoronal Core-Supported Crowns: A Proposed Treatment Alternative to Extraction for Severe Early Childhood Caries

Early childhood caries (ECC) involve extensive coronal tooth structure loss, and tooth reconstruction remains highly challenging. To fulfill preclinical assessment, the present study investigated the biomechanics of non-restorable crownless primary molars that were restored by stainless steel crowns...

Full description

Bibliographic Details
Main Authors: Kunyawan Thaungwilai, Yanee Tantilertanant, Weerachai Singhatanadgit, Pairod Singhatanadgid
Format: Article
Language:English
Published: MDPI AG 2023-02-01
Series:Journal of Clinical Medicine
Subjects:
Online Access:https://www.mdpi.com/2077-0383/12/5/1872
_version_ 1797615006289756160
author Kunyawan Thaungwilai
Yanee Tantilertanant
Weerachai Singhatanadgit
Pairod Singhatanadgid
author_facet Kunyawan Thaungwilai
Yanee Tantilertanant
Weerachai Singhatanadgit
Pairod Singhatanadgid
author_sort Kunyawan Thaungwilai
collection DOAJ
description Early childhood caries (ECC) involve extensive coronal tooth structure loss, and tooth reconstruction remains highly challenging. To fulfill preclinical assessment, the present study investigated the biomechanics of non-restorable crownless primary molars that were restored by stainless steel crowns (SSC) using different composite core build-up materials. Computer-aided design-integrated 3D finite element and modified Goodman fatigue analyses were performed to determine stress distribution, risk of failure, fatigue life and dentine–material interfacial strength for the restored crownless primary molars. A dual-cured resin composite (MultiCore Flow), a light-cured bulk-fill resin composite (Filtek Bulk Fill posterior), a resin-modified glass-ionomer cement (Fuji II LC) and a nano-filled resin-modified glass-ionomer cement (NRMGIC; Ketac N100) were used as core build-up composite materials in the simulated models. The finite element analysis showed that types of core build-up materials affected the maximum von Mises stress only in the core materials (<i>p</i>-value = 0.0339). NRMGIC demonstrated the lowest von Mises stresses and revealed the highest minimum safety factor. The weakest sites were along the central grooves regardless of type of material, and the ratio of shear bond strength to maximum shear stress at the core–dentine interface of the NRMGIC group was lowest among the tested composite cores. However, all groups provided lifetime longevity from the fatigue analysis. In conclusion, core build-up materials differentially influenced the von Mises stress (magnitude and distribution) and the safety factor in crownless primary molars restored with core-supported SSC. However, all materials and the remaining dentine of crownless primary molars provided lifetime longevity. The reconstruction by core-supported SSC, as an alternative to tooth extraction, may successfully restore non-restorable crownless primary molars without unfavorable failures throughout their lifespan. Further clinical studies are required to evaluate the clinical performance and suitability of this proposed method.
first_indexed 2024-03-11T07:20:22Z
format Article
id doaj.art-3536bd92da644a569dfe4e8a820f0033
institution Directory Open Access Journal
issn 2077-0383
language English
last_indexed 2024-03-11T07:20:22Z
publishDate 2023-02-01
publisher MDPI AG
record_format Article
series Journal of Clinical Medicine
spelling doaj.art-3536bd92da644a569dfe4e8a820f00332023-11-17T07:59:28ZengMDPI AGJournal of Clinical Medicine2077-03832023-02-01125187210.3390/jcm12051872Finite Element Analysis of the Mechanical Performance of Non-Restorable Crownless Primary Molars Restored with Intracoronal Core-Supported Crowns: A Proposed Treatment Alternative to Extraction for Severe Early Childhood CariesKunyawan Thaungwilai0Yanee Tantilertanant1Weerachai Singhatanadgit2Pairod Singhatanadgid3Composite Structures Research Unit, Department of Mechanical Engineering, Faculty of Engineering, Chulalongkorn University, Phyathai Road, Patumwan, Bangkok 10330, ThailandFaculty of Dentistry, Chulalongkorn University, Phyathai Road, Patumwan, Bangkok 10330, ThailandFaculty of Dentistry and Research Unit in Mineralized Tissue Reconstruction, Thammasat University (Rangsit Campus), Paholyothin Road, Klong Luang, Pathumthani 12121, ThailandComposite Structures Research Unit, Department of Mechanical Engineering, Faculty of Engineering, Chulalongkorn University, Phyathai Road, Patumwan, Bangkok 10330, ThailandEarly childhood caries (ECC) involve extensive coronal tooth structure loss, and tooth reconstruction remains highly challenging. To fulfill preclinical assessment, the present study investigated the biomechanics of non-restorable crownless primary molars that were restored by stainless steel crowns (SSC) using different composite core build-up materials. Computer-aided design-integrated 3D finite element and modified Goodman fatigue analyses were performed to determine stress distribution, risk of failure, fatigue life and dentine–material interfacial strength for the restored crownless primary molars. A dual-cured resin composite (MultiCore Flow), a light-cured bulk-fill resin composite (Filtek Bulk Fill posterior), a resin-modified glass-ionomer cement (Fuji II LC) and a nano-filled resin-modified glass-ionomer cement (NRMGIC; Ketac N100) were used as core build-up composite materials in the simulated models. The finite element analysis showed that types of core build-up materials affected the maximum von Mises stress only in the core materials (<i>p</i>-value = 0.0339). NRMGIC demonstrated the lowest von Mises stresses and revealed the highest minimum safety factor. The weakest sites were along the central grooves regardless of type of material, and the ratio of shear bond strength to maximum shear stress at the core–dentine interface of the NRMGIC group was lowest among the tested composite cores. However, all groups provided lifetime longevity from the fatigue analysis. In conclusion, core build-up materials differentially influenced the von Mises stress (magnitude and distribution) and the safety factor in crownless primary molars restored with core-supported SSC. However, all materials and the remaining dentine of crownless primary molars provided lifetime longevity. The reconstruction by core-supported SSC, as an alternative to tooth extraction, may successfully restore non-restorable crownless primary molars without unfavorable failures throughout their lifespan. Further clinical studies are required to evaluate the clinical performance and suitability of this proposed method.https://www.mdpi.com/2077-0383/12/5/1872early childhood cariescore build-upstainless steel crowncrownless primary molarsfinite element analysisfatigue life
spellingShingle Kunyawan Thaungwilai
Yanee Tantilertanant
Weerachai Singhatanadgit
Pairod Singhatanadgid
Finite Element Analysis of the Mechanical Performance of Non-Restorable Crownless Primary Molars Restored with Intracoronal Core-Supported Crowns: A Proposed Treatment Alternative to Extraction for Severe Early Childhood Caries
Journal of Clinical Medicine
early childhood caries
core build-up
stainless steel crown
crownless primary molars
finite element analysis
fatigue life
title Finite Element Analysis of the Mechanical Performance of Non-Restorable Crownless Primary Molars Restored with Intracoronal Core-Supported Crowns: A Proposed Treatment Alternative to Extraction for Severe Early Childhood Caries
title_full Finite Element Analysis of the Mechanical Performance of Non-Restorable Crownless Primary Molars Restored with Intracoronal Core-Supported Crowns: A Proposed Treatment Alternative to Extraction for Severe Early Childhood Caries
title_fullStr Finite Element Analysis of the Mechanical Performance of Non-Restorable Crownless Primary Molars Restored with Intracoronal Core-Supported Crowns: A Proposed Treatment Alternative to Extraction for Severe Early Childhood Caries
title_full_unstemmed Finite Element Analysis of the Mechanical Performance of Non-Restorable Crownless Primary Molars Restored with Intracoronal Core-Supported Crowns: A Proposed Treatment Alternative to Extraction for Severe Early Childhood Caries
title_short Finite Element Analysis of the Mechanical Performance of Non-Restorable Crownless Primary Molars Restored with Intracoronal Core-Supported Crowns: A Proposed Treatment Alternative to Extraction for Severe Early Childhood Caries
title_sort finite element analysis of the mechanical performance of non restorable crownless primary molars restored with intracoronal core supported crowns a proposed treatment alternative to extraction for severe early childhood caries
topic early childhood caries
core build-up
stainless steel crown
crownless primary molars
finite element analysis
fatigue life
url https://www.mdpi.com/2077-0383/12/5/1872
work_keys_str_mv AT kunyawanthaungwilai finiteelementanalysisofthemechanicalperformanceofnonrestorablecrownlessprimarymolarsrestoredwithintracoronalcoresupportedcrownsaproposedtreatmentalternativetoextractionforsevereearlychildhoodcaries
AT yaneetantilertanant finiteelementanalysisofthemechanicalperformanceofnonrestorablecrownlessprimarymolarsrestoredwithintracoronalcoresupportedcrownsaproposedtreatmentalternativetoextractionforsevereearlychildhoodcaries
AT weerachaisinghatanadgit finiteelementanalysisofthemechanicalperformanceofnonrestorablecrownlessprimarymolarsrestoredwithintracoronalcoresupportedcrownsaproposedtreatmentalternativetoextractionforsevereearlychildhoodcaries
AT pairodsinghatanadgid finiteelementanalysisofthemechanicalperformanceofnonrestorablecrownlessprimarymolarsrestoredwithintracoronalcoresupportedcrownsaproposedtreatmentalternativetoextractionforsevereearlychildhoodcaries