Biocompatible Sulphonated PEEK Spheres: Influence of Processing Conditions on Morphology and Swelling Behavior

This work aimed to develop and evaluate the influence of processing variables on the morphology and swelling of sulfonated poly(ether ether ketone) (SPEEK) spheres for possible applications as a biomaterial. We used the drip method to obtain spheres with the polymer starting solutions SPEEK-6 (<i...

Full description

Bibliographic Details
Main Authors: Mayelli Dantas de Sá, José William de Lima Souza, Henrique Nunes da Silva, Rodolfo Henrique Nogueira Torres, Michele Dayane Rodrigues Leite, Rossemberg Cardoso Barbosa, Itamara Farias Leite, Cristiane Agra Pimentel, Marcus Vinicius Lia Fook
Format: Article
Language:English
Published: MDPI AG 2021-08-01
Series:Polymers
Subjects:
Online Access:https://www.mdpi.com/2073-4360/13/17/2920
Description
Summary:This work aimed to develop and evaluate the influence of processing variables on the morphology and swelling of sulfonated poly(ether ether ketone) (SPEEK) spheres for possible applications as a biomaterial. We used the drip method to obtain spheres with the polymer starting solutions SPEEK-6 (<i>w</i>/<i>v</i>: 6%) and SPEEK-10 (<i>w</i>/<i>v</i>: 10%), drip rates (20 and 30 mL/h), and drip heights (5 and 10 cm) in experimental planning. The samples were characterized by Fourier-transform infrared spectroscopy (FTIR), optical microscopy (OM), the absorption capacity of phosphate-buffered saline (PBS) by swelling (%), and statistical analysis of data through Design of Experiments (DOE). The obtained results evidenced that the processing variables influenced the morphology and swelling. Spheres with a bigger concentration of the polymer solution presented a greater degree of sulfonation (DS). We verified that the diameter of the spheres was directly related to the variable height and the sphericity was associated with the speed and viscosity of the solution. Bigger and more pores in a greater amount were observed in the spheres with a greater DS, influencing the behavior of the swelling in PBS. The better variable combinations with a high DS, regular sphericity, a smaller diameter, and greater swelling were the samples S<sub>2</sub>-10-20-5 e S<sub>10</sub>-10-20-5. The cytotoxicity indicated that the best samples obtained in the experimental planning (S<sub>2</sub>-10-20-5 and S<sub>10</sub>-10-20-5) were not toxic. In that regard, the evaluated spheres presented cell viability and swelling capacity, suggesting their possible applications as biomaterials.
ISSN:2073-4360