Determination of the Molecular Weight of Low-Molecular-Weight Heparins by Using High-Pressure Size Exclusion Chromatography on Line with a Triple Detector Array and Conventional Methods

The evaluation of weight average molecular weight (Mw) and molecular weight distribution represents one of the most controversial aspects concerning the characterization of low molecular weight heparins (LMWHs). As the most commonly used method for the measurement of such parameters is high perform...

Full description

Bibliographic Details
Main Authors: Antonella Bisio, Alessandra Mantegazza, Davide Vecchietti, Donata Bensi, Alessia Coppa, Giangiacomo Torri, Sabrina Bertini
Format: Article
Language:English
Published: MDPI AG 2015-03-01
Series:Molecules
Subjects:
Online Access:http://www.mdpi.com/1420-3049/20/3/5085
_version_ 1819072470356852736
author Antonella Bisio
Alessandra Mantegazza
Davide Vecchietti
Donata Bensi
Alessia Coppa
Giangiacomo Torri
Sabrina Bertini
author_facet Antonella Bisio
Alessandra Mantegazza
Davide Vecchietti
Donata Bensi
Alessia Coppa
Giangiacomo Torri
Sabrina Bertini
author_sort Antonella Bisio
collection DOAJ
description The evaluation of weight average molecular weight (Mw) and molecular weight distribution represents one of the most controversial aspects concerning the characterization of low molecular weight heparins (LMWHs). As the most commonly used method for the measurement of such parameters is high performance size exclusion chromatography (HP-SEC), the soundness of results mainly depends on the appropriate calibration of the chromatographic columns used. With the aim of meeting the requirement of proper Mw standards for LMWHs, in the present work the determination of molecular weight parameters (Mw and Mn) by HP-SEC combined with a triple detector array (TDA) was performed. The HP-SEC/TDA technique permits the evaluation of polymeric samples by exploiting the combined and simultaneous action of three on-line detectors: light scattering detectors (LALLS/RALLS); refractometer and viscometer. Three commercial LMWH samples, enoxaparin, tinzaparin and dalteparin, a γ-ray depolymerized heparin (γ-Hep) and its chromatographic fractions, and a synthetic pentasaccharide were analysed by HP-SEC/TDA. The same samples were analysed also with a conventional HP-SEC method employing refractive index (RI) and UV detectors and two different chromatographic column set, silica gel and polymeric gel columns. In both chromatographic systems, two different calibration curves were built up by using (i) γ-Hep chromatographic fractions and the corresponding Mw parameters obtained via HP-SEC/TDA; (ii) the whole γ-Hep preparation with broad Mw dispersion and the corresponding cumulative distribution function calculated via HP-SEC/TDA. In addition, also a chromatographic column calibration according to European Pharmacopoeia indication was built up. By comparing all the obtained results, some important differences among Mw and size distribution values of the three LMWHs were found with the five different calibration methods and with HP-SEC/TDA method. In particular, the detection of the lower molecular weight components turned out to be the most critical aspect. Whereas HP-SEC/TDA may underestimate species under 2 KDa when present in low concentration, other methods appeared to emphasize their content.
first_indexed 2024-12-21T17:38:14Z
format Article
id doaj.art-35c3f9a7106f4ca383edaa9f961dc5cc
institution Directory Open Access Journal
issn 1420-3049
language English
last_indexed 2024-12-21T17:38:14Z
publishDate 2015-03-01
publisher MDPI AG
record_format Article
series Molecules
spelling doaj.art-35c3f9a7106f4ca383edaa9f961dc5cc2022-12-21T18:55:42ZengMDPI AGMolecules1420-30492015-03-012035085509810.3390/molecules20035085molecules20035085Determination of the Molecular Weight of Low-Molecular-Weight Heparins by Using High-Pressure Size Exclusion Chromatography on Line with a Triple Detector Array and Conventional MethodsAntonella Bisio0Alessandra Mantegazza1Davide Vecchietti2Donata Bensi3Alessia Coppa4Giangiacomo Torri5Sabrina Bertini6Istituto di Ricerche Chimiche e Biochimiche G. Ronzoni, via G. Colombo 81, Milan 20133, ItalyIstituto di Ricerche Chimiche e Biochimiche G. Ronzoni, via G. Colombo 81, Milan 20133, ItalyIstituto di Ricerche Chimiche e Biochimiche G. Ronzoni, via G. Colombo 81, Milan 20133, ItalyLaboratori Derivati Organici, via M. Barozzi 4, Milan 20122, ItalyLaboratori Derivati Organici, via M. Barozzi 4, Milan 20122, ItalyIstituto di Ricerche Chimiche e Biochimiche G. Ronzoni, via G. Colombo 81, Milan 20133, ItalyIstituto di Ricerche Chimiche e Biochimiche G. Ronzoni, via G. Colombo 81, Milan 20133, ItalyThe evaluation of weight average molecular weight (Mw) and molecular weight distribution represents one of the most controversial aspects concerning the characterization of low molecular weight heparins (LMWHs). As the most commonly used method for the measurement of such parameters is high performance size exclusion chromatography (HP-SEC), the soundness of results mainly depends on the appropriate calibration of the chromatographic columns used. With the aim of meeting the requirement of proper Mw standards for LMWHs, in the present work the determination of molecular weight parameters (Mw and Mn) by HP-SEC combined with a triple detector array (TDA) was performed. The HP-SEC/TDA technique permits the evaluation of polymeric samples by exploiting the combined and simultaneous action of three on-line detectors: light scattering detectors (LALLS/RALLS); refractometer and viscometer. Three commercial LMWH samples, enoxaparin, tinzaparin and dalteparin, a γ-ray depolymerized heparin (γ-Hep) and its chromatographic fractions, and a synthetic pentasaccharide were analysed by HP-SEC/TDA. The same samples were analysed also with a conventional HP-SEC method employing refractive index (RI) and UV detectors and two different chromatographic column set, silica gel and polymeric gel columns. In both chromatographic systems, two different calibration curves were built up by using (i) γ-Hep chromatographic fractions and the corresponding Mw parameters obtained via HP-SEC/TDA; (ii) the whole γ-Hep preparation with broad Mw dispersion and the corresponding cumulative distribution function calculated via HP-SEC/TDA. In addition, also a chromatographic column calibration according to European Pharmacopoeia indication was built up. By comparing all the obtained results, some important differences among Mw and size distribution values of the three LMWHs were found with the five different calibration methods and with HP-SEC/TDA method. In particular, the detection of the lower molecular weight components turned out to be the most critical aspect. Whereas HP-SEC/TDA may underestimate species under 2 KDa when present in low concentration, other methods appeared to emphasize their content.http://www.mdpi.com/1420-3049/20/3/5085low molecular weight heparinssize exclusion chromatographylaser light scattering
spellingShingle Antonella Bisio
Alessandra Mantegazza
Davide Vecchietti
Donata Bensi
Alessia Coppa
Giangiacomo Torri
Sabrina Bertini
Determination of the Molecular Weight of Low-Molecular-Weight Heparins by Using High-Pressure Size Exclusion Chromatography on Line with a Triple Detector Array and Conventional Methods
Molecules
low molecular weight heparins
size exclusion chromatography
laser light scattering
title Determination of the Molecular Weight of Low-Molecular-Weight Heparins by Using High-Pressure Size Exclusion Chromatography on Line with a Triple Detector Array and Conventional Methods
title_full Determination of the Molecular Weight of Low-Molecular-Weight Heparins by Using High-Pressure Size Exclusion Chromatography on Line with a Triple Detector Array and Conventional Methods
title_fullStr Determination of the Molecular Weight of Low-Molecular-Weight Heparins by Using High-Pressure Size Exclusion Chromatography on Line with a Triple Detector Array and Conventional Methods
title_full_unstemmed Determination of the Molecular Weight of Low-Molecular-Weight Heparins by Using High-Pressure Size Exclusion Chromatography on Line with a Triple Detector Array and Conventional Methods
title_short Determination of the Molecular Weight of Low-Molecular-Weight Heparins by Using High-Pressure Size Exclusion Chromatography on Line with a Triple Detector Array and Conventional Methods
title_sort determination of the molecular weight of low molecular weight heparins by using high pressure size exclusion chromatography on line with a triple detector array and conventional methods
topic low molecular weight heparins
size exclusion chromatography
laser light scattering
url http://www.mdpi.com/1420-3049/20/3/5085
work_keys_str_mv AT antonellabisio determinationofthemolecularweightoflowmolecularweightheparinsbyusinghighpressuresizeexclusionchromatographyonlinewithatripledetectorarrayandconventionalmethods
AT alessandramantegazza determinationofthemolecularweightoflowmolecularweightheparinsbyusinghighpressuresizeexclusionchromatographyonlinewithatripledetectorarrayandconventionalmethods
AT davidevecchietti determinationofthemolecularweightoflowmolecularweightheparinsbyusinghighpressuresizeexclusionchromatographyonlinewithatripledetectorarrayandconventionalmethods
AT donatabensi determinationofthemolecularweightoflowmolecularweightheparinsbyusinghighpressuresizeexclusionchromatographyonlinewithatripledetectorarrayandconventionalmethods
AT alessiacoppa determinationofthemolecularweightoflowmolecularweightheparinsbyusinghighpressuresizeexclusionchromatographyonlinewithatripledetectorarrayandconventionalmethods
AT giangiacomotorri determinationofthemolecularweightoflowmolecularweightheparinsbyusinghighpressuresizeexclusionchromatographyonlinewithatripledetectorarrayandconventionalmethods
AT sabrinabertini determinationofthemolecularweightoflowmolecularweightheparinsbyusinghighpressuresizeexclusionchromatographyonlinewithatripledetectorarrayandconventionalmethods