The effect of corneal crosslinking on the rigidity of the cornea estimated using a modified algorithm for the Schiøtz tonometer

Purpose: The aim of this study was to test a method for estimating corneal rigidity before and after cross-linking (CXL) using a Schiøtz tonometer. Methods: The study was performed in the Kyiv City Clinical Ophthalmological Hospital “Eye Microsurgical Center”, Ukraine. This was a prospective, consec...

Full description

Bibliographic Details
Main Authors: Larysa Tutchenko, Sudi Patel, Mykhailo Skovron, Olha Horak, Oleksiy Voytsekhivskyy
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2021-01-01
Series:Indian Journal of Ophthalmology
Subjects:
Online Access:http://www.ijo.in/article.asp?issn=0301-4738;year=2021;volume=69;issue=6;spage=1531;epage=1536;aulast=Tutchenko
_version_ 1818621587743571968
author Larysa Tutchenko
Sudi Patel
Mykhailo Skovron
Olha Horak
Oleksiy Voytsekhivskyy
author_facet Larysa Tutchenko
Sudi Patel
Mykhailo Skovron
Olha Horak
Oleksiy Voytsekhivskyy
author_sort Larysa Tutchenko
collection DOAJ
description Purpose: The aim of this study was to test a method for estimating corneal rigidity before and after cross-linking (CXL) using a Schiøtz tonometer. Methods: The study was performed in the Kyiv City Clinical Ophthalmological Hospital “Eye Microsurgical Center”, Ukraine. This was a prospective, consecutive, randomized, masked, case-by-case, clinical study. Corneal rigidity, indicated by the gradient (G) between lg applied weight and corresponding lg scale reading during Schiøtz tonometry, were obtained by increasing (A-mode) then reducing (D-mode) weights by two operators [A] in keratoconus, post-CXL and control subjects for estimation of (i) interoperator and (ii) intersessional errors, (iii) intergroup differences; [B] before and after CXL. Central corneal thickness CCT was measured by scanning slit pachymetry. ANOVA, t tests, linear regression were the statistical tools used. Results: Average interoperator difference (ΔG) was –0.120 (SD = ±0.294, 95%CI = –0.175 to –0.066). A significant correlation between ΔG and the mean of each pair of G values was found (r = –0.196, n = 112, P = 0.038). Intersessional differences in mean G values were insignificant (P > 0.05). There was a significant correlation between G at first session (X1) and difference between sessions (ΔG) [Operator 1, ΔG = 0.598x1–0.461, r = 0.601, n = 27, P = 0.009]. Significant intergroup differences in G were found (Operator 1, one-way ANOVA, F = 4.489, P = 0.014). The difference (Δ) between the pre-(X2) and post-CXL treatment G values was significantly associated with the pre-CXL treatment value (Operator 1, Δ = 1.970x2-1.622, r = 0.642, n = 18, P = <.001). G values were correlated with CCT in keratoconus and post-CXL. Conclusion: Corneal rigidity (G) estimated using the Schiøtz tonometer can be useful for detecting changes after CXL. However, G values are linked to CCT, can vary from time-to-time and the procedure is operator dependent.
first_indexed 2024-12-16T18:11:39Z
format Article
id doaj.art-35f91dabb9574861815f1709e61f49e6
institution Directory Open Access Journal
issn 0301-4738
1998-3689
language English
last_indexed 2024-12-16T18:11:39Z
publishDate 2021-01-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series Indian Journal of Ophthalmology
spelling doaj.art-35f91dabb9574861815f1709e61f49e62022-12-21T22:21:45ZengWolters Kluwer Medknow PublicationsIndian Journal of Ophthalmology0301-47381998-36892021-01-016961531153610.4103/ijo.IJO_1820_20The effect of corneal crosslinking on the rigidity of the cornea estimated using a modified algorithm for the Schiøtz tonometerLarysa TutchenkoSudi PatelMykhailo SkovronOlha HorakOleksiy VoytsekhivskyyPurpose: The aim of this study was to test a method for estimating corneal rigidity before and after cross-linking (CXL) using a Schiøtz tonometer. Methods: The study was performed in the Kyiv City Clinical Ophthalmological Hospital “Eye Microsurgical Center”, Ukraine. This was a prospective, consecutive, randomized, masked, case-by-case, clinical study. Corneal rigidity, indicated by the gradient (G) between lg applied weight and corresponding lg scale reading during Schiøtz tonometry, were obtained by increasing (A-mode) then reducing (D-mode) weights by two operators [A] in keratoconus, post-CXL and control subjects for estimation of (i) interoperator and (ii) intersessional errors, (iii) intergroup differences; [B] before and after CXL. Central corneal thickness CCT was measured by scanning slit pachymetry. ANOVA, t tests, linear regression were the statistical tools used. Results: Average interoperator difference (ΔG) was –0.120 (SD = ±0.294, 95%CI = –0.175 to –0.066). A significant correlation between ΔG and the mean of each pair of G values was found (r = –0.196, n = 112, P = 0.038). Intersessional differences in mean G values were insignificant (P > 0.05). There was a significant correlation between G at first session (X1) and difference between sessions (ΔG) [Operator 1, ΔG = 0.598x1–0.461, r = 0.601, n = 27, P = 0.009]. Significant intergroup differences in G were found (Operator 1, one-way ANOVA, F = 4.489, P = 0.014). The difference (Δ) between the pre-(X2) and post-CXL treatment G values was significantly associated with the pre-CXL treatment value (Operator 1, Δ = 1.970x2-1.622, r = 0.642, n = 18, P = <.001). G values were correlated with CCT in keratoconus and post-CXL. Conclusion: Corneal rigidity (G) estimated using the Schiøtz tonometer can be useful for detecting changes after CXL. However, G values are linked to CCT, can vary from time-to-time and the procedure is operator dependent.http://www.ijo.in/article.asp?issn=0301-4738;year=2021;volume=69;issue=6;spage=1531;epage=1536;aulast=Tutchenkocorneacxlrigidityschiøtz tonometer
spellingShingle Larysa Tutchenko
Sudi Patel
Mykhailo Skovron
Olha Horak
Oleksiy Voytsekhivskyy
The effect of corneal crosslinking on the rigidity of the cornea estimated using a modified algorithm for the Schiøtz tonometer
Indian Journal of Ophthalmology
cornea
cxl
rigidity
schiøtz tonometer
title The effect of corneal crosslinking on the rigidity of the cornea estimated using a modified algorithm for the Schiøtz tonometer
title_full The effect of corneal crosslinking on the rigidity of the cornea estimated using a modified algorithm for the Schiøtz tonometer
title_fullStr The effect of corneal crosslinking on the rigidity of the cornea estimated using a modified algorithm for the Schiøtz tonometer
title_full_unstemmed The effect of corneal crosslinking on the rigidity of the cornea estimated using a modified algorithm for the Schiøtz tonometer
title_short The effect of corneal crosslinking on the rigidity of the cornea estimated using a modified algorithm for the Schiøtz tonometer
title_sort effect of corneal crosslinking on the rigidity of the cornea estimated using a modified algorithm for the schiotz tonometer
topic cornea
cxl
rigidity
schiøtz tonometer
url http://www.ijo.in/article.asp?issn=0301-4738;year=2021;volume=69;issue=6;spage=1531;epage=1536;aulast=Tutchenko
work_keys_str_mv AT larysatutchenko theeffectofcornealcrosslinkingontherigidityofthecorneaestimatedusingamodifiedalgorithmfortheschiøtztonometer
AT sudipatel theeffectofcornealcrosslinkingontherigidityofthecorneaestimatedusingamodifiedalgorithmfortheschiøtztonometer
AT mykhailoskovron theeffectofcornealcrosslinkingontherigidityofthecorneaestimatedusingamodifiedalgorithmfortheschiøtztonometer
AT olhahorak theeffectofcornealcrosslinkingontherigidityofthecorneaestimatedusingamodifiedalgorithmfortheschiøtztonometer
AT oleksiyvoytsekhivskyy theeffectofcornealcrosslinkingontherigidityofthecorneaestimatedusingamodifiedalgorithmfortheschiøtztonometer
AT larysatutchenko effectofcornealcrosslinkingontherigidityofthecorneaestimatedusingamodifiedalgorithmfortheschiøtztonometer
AT sudipatel effectofcornealcrosslinkingontherigidityofthecorneaestimatedusingamodifiedalgorithmfortheschiøtztonometer
AT mykhailoskovron effectofcornealcrosslinkingontherigidityofthecorneaestimatedusingamodifiedalgorithmfortheschiøtztonometer
AT olhahorak effectofcornealcrosslinkingontherigidityofthecorneaestimatedusingamodifiedalgorithmfortheschiøtztonometer
AT oleksiyvoytsekhivskyy effectofcornealcrosslinkingontherigidityofthecorneaestimatedusingamodifiedalgorithmfortheschiøtztonometer