Comparison of Axillary Loop and Straight Grafts Patency and Their Complications for Hemodialylis Access

Introduction & Objective: Dialysis vascular access complications are important causes of morbidity in chronic hemodialysis patients. The aim of the present study was a comparison of auxillary loop and atraight grafts patency and its complications for hemodialysis access. Materials & Methods...

Full description

Bibliographic Details
Main Authors: J KHoshnevis, M Samsami, AH Jalali, M Falahzavareh, F Hoseinizadegan Shirazi
Format: Article
Language:fas
Published: Yasuj University Of Medical Sciences 2011-08-01
Series:Armaghane Danesh Bimonthly Journal
Subjects:
Online Access:http://armaghanj.yums.ac.ir/browse.php?a_code=A-10-1-215&slc_lang=en&sid=1
_version_ 1818024626738954240
author J KHoshnevis
M Samsami
AH Jalali
M Falahzavareh
F Hoseinizadegan Shirazi
F Hoseinizadegan Shirazi
author_facet J KHoshnevis
M Samsami
AH Jalali
M Falahzavareh
F Hoseinizadegan Shirazi
F Hoseinizadegan Shirazi
author_sort J KHoshnevis
collection DOAJ
description Introduction & Objective: Dialysis vascular access complications are important causes of morbidity in chronic hemodialysis patients. The aim of the present study was a comparison of auxillary loop and atraight grafts patency and its complications for hemodialysis access. Materials & Methods: In this cohort study conducted at Shahid Beheshti Medical University, 58 patients who underwent placement of loop or straight access grafts were included in the study. Demographics, primary and secondary patency rates and complications like thrombosis, infection, bleeding, steal syndrome and other complications were compared in these two groups. The collected data was analyzed by the SPSS statistical software using the chi-square test, t-test, and logistic regression. Results: Thrombosis rates were 51.1% and 53.8% in straight and loop groups respectively (P=0.862), steal syndrome rates were 2.2% and 7.7% in straight and loop groups respectively (P=0.341), psudoanevrism were 11.1% and 23.1% in straight and loop groups respectively (P=0.270), bleeding rates were 4.4% and 0% in straight and loop groups respectively (P=0.439), infection rate were 8.9% and 7.7% in straight and loop groups respectively (P=0.892), and primary patency rate after 1 month were 88.9% and 92.3% respectively (P=0.721), and primary patency rate after 24 month were 31% and 55.5% respectively (P=0.058). Secondary patency rate after 3 month were 75.6% and 92.3% respectively (P=0.189), and secondary patency rate after 24 month were 37.9% and 66.7% respectively (P=0.044). Conclusion: PTFE vascular graft seems to be an appropriate vascular access and is a promising alternative when upper extremity arteriovenous fistulas cannot be constructed. Additionally, there was no significant different between two groups for complications and early patency, but late patency was better in loop group. More study is necessary for final judgment.
first_indexed 2024-12-10T04:03:13Z
format Article
id doaj.art-36130a6c0e994be880fb1a6b1e486a9e
institution Directory Open Access Journal
issn 1728-6506
1728-6514
language fas
last_indexed 2024-12-10T04:03:13Z
publishDate 2011-08-01
publisher Yasuj University Of Medical Sciences
record_format Article
series Armaghane Danesh Bimonthly Journal
spelling doaj.art-36130a6c0e994be880fb1a6b1e486a9e2022-12-22T02:02:56ZfasYasuj University Of Medical SciencesArmaghane Danesh Bimonthly Journal1728-65061728-65142011-08-01163211220Comparison of Axillary Loop and Straight Grafts Patency and Their Complications for Hemodialylis AccessJ KHoshnevis0M Samsami1AH Jalali2M Falahzavareh3F Hoseinizadegan Shirazi4F Hoseinizadegan Shirazi5 Introduction & Objective: Dialysis vascular access complications are important causes of morbidity in chronic hemodialysis patients. The aim of the present study was a comparison of auxillary loop and atraight grafts patency and its complications for hemodialysis access. Materials & Methods: In this cohort study conducted at Shahid Beheshti Medical University, 58 patients who underwent placement of loop or straight access grafts were included in the study. Demographics, primary and secondary patency rates and complications like thrombosis, infection, bleeding, steal syndrome and other complications were compared in these two groups. The collected data was analyzed by the SPSS statistical software using the chi-square test, t-test, and logistic regression. Results: Thrombosis rates were 51.1% and 53.8% in straight and loop groups respectively (P=0.862), steal syndrome rates were 2.2% and 7.7% in straight and loop groups respectively (P=0.341), psudoanevrism were 11.1% and 23.1% in straight and loop groups respectively (P=0.270), bleeding rates were 4.4% and 0% in straight and loop groups respectively (P=0.439), infection rate were 8.9% and 7.7% in straight and loop groups respectively (P=0.892), and primary patency rate after 1 month were 88.9% and 92.3% respectively (P=0.721), and primary patency rate after 24 month were 31% and 55.5% respectively (P=0.058). Secondary patency rate after 3 month were 75.6% and 92.3% respectively (P=0.189), and secondary patency rate after 24 month were 37.9% and 66.7% respectively (P=0.044). Conclusion: PTFE vascular graft seems to be an appropriate vascular access and is a promising alternative when upper extremity arteriovenous fistulas cannot be constructed. Additionally, there was no significant different between two groups for complications and early patency, but late patency was better in loop group. More study is necessary for final judgment.http://armaghanj.yums.ac.ir/browse.php?a_code=A-10-1-215&slc_lang=en&sid=1 Hemodialysis Loop Graft Straight Graft
spellingShingle J KHoshnevis
M Samsami
AH Jalali
M Falahzavareh
F Hoseinizadegan Shirazi
F Hoseinizadegan Shirazi
Comparison of Axillary Loop and Straight Grafts Patency and Their Complications for Hemodialylis Access
Armaghane Danesh Bimonthly Journal
Hemodialysis
Loop Graft
Straight Graft
title Comparison of Axillary Loop and Straight Grafts Patency and Their Complications for Hemodialylis Access
title_full Comparison of Axillary Loop and Straight Grafts Patency and Their Complications for Hemodialylis Access
title_fullStr Comparison of Axillary Loop and Straight Grafts Patency and Their Complications for Hemodialylis Access
title_full_unstemmed Comparison of Axillary Loop and Straight Grafts Patency and Their Complications for Hemodialylis Access
title_short Comparison of Axillary Loop and Straight Grafts Patency and Their Complications for Hemodialylis Access
title_sort comparison of axillary loop and straight grafts patency and their complications for hemodialylis access
topic Hemodialysis
Loop Graft
Straight Graft
url http://armaghanj.yums.ac.ir/browse.php?a_code=A-10-1-215&slc_lang=en&sid=1
work_keys_str_mv AT jkhoshnevis comparisonofaxillaryloopandstraightgraftspatencyandtheircomplicationsforhemodialylisaccess
AT msamsami comparisonofaxillaryloopandstraightgraftspatencyandtheircomplicationsforhemodialylisaccess
AT ahjalali comparisonofaxillaryloopandstraightgraftspatencyandtheircomplicationsforhemodialylisaccess
AT mfalahzavareh comparisonofaxillaryloopandstraightgraftspatencyandtheircomplicationsforhemodialylisaccess
AT fhoseinizadeganshirazi comparisonofaxillaryloopandstraightgraftspatencyandtheircomplicationsforhemodialylisaccess
AT fhoseinizadeganshirazi comparisonofaxillaryloopandstraightgraftspatencyandtheircomplicationsforhemodialylisaccess