Research on the Neutral-Point Voltage Balance for NPC Three-Level Inverters under Non-Ideal Grid Conditions

In order to solve the neutral-point voltage unbalancing problem for neutral-point clamped (NPC) three-level inverters under non-ideal grid conditions, a novel zero-sequence component injection method for modulation signals was proposed in this paper. Based on the mathematical expressions of neutral-...

Full description

Bibliographic Details
Main Authors: Jian Guo Lyu, Ji Dong Wang, Wen Bin Hu, Zhao Feng Wu
Format: Article
Language:English
Published: MDPI AG 2018-05-01
Series:Energies
Subjects:
Online Access:http://www.mdpi.com/1996-1073/11/6/1331
_version_ 1798002412032622592
author Jian Guo Lyu
Ji Dong Wang
Wen Bin Hu
Zhao Feng Wu
author_facet Jian Guo Lyu
Ji Dong Wang
Wen Bin Hu
Zhao Feng Wu
author_sort Jian Guo Lyu
collection DOAJ
description In order to solve the neutral-point voltage unbalancing problem for neutral-point clamped (NPC) three-level inverters under non-ideal grid conditions, a novel zero-sequence component injection method for modulation signals was proposed in this paper. Based on the mathematical expressions of neutral-point voltage unbalancing, the fluctuation of the neutral-point voltage under different grid conditions was studied. The proposed method dynamically calculates the zero-sequence component for modulation signals by region selections based on sinusoidal pulse width modulation (DCR-SPWM). Under non-ideal grid conditions, this DCR-SPWM method can control the neutral-point voltage balance for NPC three-level inverters with different grid and output power conditions, and improves the grid current quality. The simulation results verified the correctness of the theoretical analysis in this paper, and the feasibility and effectiveness of this method were verified by the experiments in the experimental platform of the NPC three-level grid-connected inverter based on DSP-CPLD controllers.
first_indexed 2024-04-11T11:52:51Z
format Article
id doaj.art-3630cc4ed16b43cba6d3d9aedbef4552
institution Directory Open Access Journal
issn 1996-1073
language English
last_indexed 2024-04-11T11:52:51Z
publishDate 2018-05-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj.art-3630cc4ed16b43cba6d3d9aedbef45522022-12-22T04:25:16ZengMDPI AGEnergies1996-10732018-05-01116133110.3390/en11061331en11061331Research on the Neutral-Point Voltage Balance for NPC Three-Level Inverters under Non-Ideal Grid ConditionsJian Guo Lyu0Ji Dong Wang1Wen Bin Hu2Zhao Feng Wu3Nanjing University of Science and Technology, Nanjing 210094, ChinaNanjing University of Science and Technology, Nanjing 210094, ChinaNanjing University of Science and Technology, Nanjing 210094, ChinaNanjing University of Science and Technology, Nanjing 210094, ChinaIn order to solve the neutral-point voltage unbalancing problem for neutral-point clamped (NPC) three-level inverters under non-ideal grid conditions, a novel zero-sequence component injection method for modulation signals was proposed in this paper. Based on the mathematical expressions of neutral-point voltage unbalancing, the fluctuation of the neutral-point voltage under different grid conditions was studied. The proposed method dynamically calculates the zero-sequence component for modulation signals by region selections based on sinusoidal pulse width modulation (DCR-SPWM). Under non-ideal grid conditions, this DCR-SPWM method can control the neutral-point voltage balance for NPC three-level inverters with different grid and output power conditions, and improves the grid current quality. The simulation results verified the correctness of the theoretical analysis in this paper, and the feasibility and effectiveness of this method were verified by the experiments in the experimental platform of the NPC three-level grid-connected inverter based on DSP-CPLD controllers.http://www.mdpi.com/1996-1073/11/6/1331non-ideal gridthree-level invertersneutral-point voltage balancemodulation signalsregion selection
spellingShingle Jian Guo Lyu
Ji Dong Wang
Wen Bin Hu
Zhao Feng Wu
Research on the Neutral-Point Voltage Balance for NPC Three-Level Inverters under Non-Ideal Grid Conditions
Energies
non-ideal grid
three-level inverters
neutral-point voltage balance
modulation signals
region selection
title Research on the Neutral-Point Voltage Balance for NPC Three-Level Inverters under Non-Ideal Grid Conditions
title_full Research on the Neutral-Point Voltage Balance for NPC Three-Level Inverters under Non-Ideal Grid Conditions
title_fullStr Research on the Neutral-Point Voltage Balance for NPC Three-Level Inverters under Non-Ideal Grid Conditions
title_full_unstemmed Research on the Neutral-Point Voltage Balance for NPC Three-Level Inverters under Non-Ideal Grid Conditions
title_short Research on the Neutral-Point Voltage Balance for NPC Three-Level Inverters under Non-Ideal Grid Conditions
title_sort research on the neutral point voltage balance for npc three level inverters under non ideal grid conditions
topic non-ideal grid
three-level inverters
neutral-point voltage balance
modulation signals
region selection
url http://www.mdpi.com/1996-1073/11/6/1331
work_keys_str_mv AT jianguolyu researchontheneutralpointvoltagebalancefornpcthreelevelinvertersundernonidealgridconditions
AT jidongwang researchontheneutralpointvoltagebalancefornpcthreelevelinvertersundernonidealgridconditions
AT wenbinhu researchontheneutralpointvoltagebalancefornpcthreelevelinvertersundernonidealgridconditions
AT zhaofengwu researchontheneutralpointvoltagebalancefornpcthreelevelinvertersundernonidealgridconditions