Uniformity of Dose Distribution in Target Volume in Radiotherapy Techniques for Breast after Mastectomy.
Background & Objective: Radiotherapy has a very special significance in the treatment of cancer. Beam radiation therapy using photons and electrons produced by a linear accelerator is used extensively in the treatment of breast Cancer. In this article, In addition to providing a description of t...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | fas |
Published: |
Fasa University of Medical Sciences
2014-03-01
|
Series: | Journal of Fasa University of Medical Sciences |
Subjects: | |
Online Access: | http://journal.fums.ac.ir/browse.php?a_code=A-10-199-1&slc_lang=en&sid=1 |
_version_ | 1819259105431257088 |
---|---|
author | Sajad Pashton shayesteh Abas Haghparast Masomeh Seidi Behrouz Moradhasel Mostafa Taghi Pour |
author_facet | Sajad Pashton shayesteh Abas Haghparast Masomeh Seidi Behrouz Moradhasel Mostafa Taghi Pour |
author_sort | Sajad Pashton shayesteh |
collection | DOAJ |
description | Background & Objective: Radiotherapy has a very special significance in the treatment of cancer. Beam radiation therapy using photons and electrons produced by a linear accelerator is used extensively in the treatment of breast Cancer. In this article, In addition to providing a description of three techniques of radiotherapy in the treatment of breast cancer, has been Evaluating the effectiveness of this method in the base of uniformity of the dose distribution in the target volume in breast cancer as an important factor in the effectiveness of treatment by radiation.Materials & Methods: Photon, electron and arc Techniques in radiotherapy have been implemented practically using phantom trunk and EDRII films. At the time of practical Techniques, films were placed between the slice of the phantom and were irradiated under selected conditions and the data of these images are analyzed by MATLAB software.Results: Studies show that as a result of using adjacent fields in whole radiotherapy techniques, Parts of the target volume received dose twice or more than the prescribed dose. Meanwhile, by the photon dose technique, rate of receiving dose is more uniform and closer to the prescribed dose.Conclusion: According to scientific studies done by different protocols in breast radiotherapy, tangential photon technique has very less overlap of the field by comparison to other methods and more uniform dose distribution than the prescribed dose .In The base of this research results can be announced the photon techniques in breast cancer treatment was preferred over other methods. |
first_indexed | 2024-12-23T19:04:43Z |
format | Article |
id | doaj.art-369a083bf11148939ae4fbcf01dbfcd4 |
institution | Directory Open Access Journal |
issn | 2228-5105 2228-7329 |
language | fas |
last_indexed | 2024-12-23T19:04:43Z |
publishDate | 2014-03-01 |
publisher | Fasa University of Medical Sciences |
record_format | Article |
series | Journal of Fasa University of Medical Sciences |
spelling | doaj.art-369a083bf11148939ae4fbcf01dbfcd42022-12-21T17:34:38ZfasFasa University of Medical SciencesJournal of Fasa University of Medical Sciences2228-51052228-73292014-03-0134355362Uniformity of Dose Distribution in Target Volume in Radiotherapy Techniques for Breast after Mastectomy.Sajad Pashton shayesteh 0Abas Haghparast 1Masomeh Seidi2Behrouz Moradhasel3Mostafa Taghi Pour 4 Department of Medical physics, Kermanshah University of Medical Sciences, Kermanshah, Iran Department of Medical physics, Kermanshah University of Medical Sciences, Kermanshah, Iran Instructor, Education Development Center, Hamadan University of Medical Sciences, Hamadan, Iran. Department of Biomedical Engineering, Kermanshah University of Medical Sciences, Kermanshah, Iran. Department of Biomedical Engineering, Kermanshah University of Medical Sciences, Kermanshah, Iran. Background & Objective: Radiotherapy has a very special significance in the treatment of cancer. Beam radiation therapy using photons and electrons produced by a linear accelerator is used extensively in the treatment of breast Cancer. In this article, In addition to providing a description of three techniques of radiotherapy in the treatment of breast cancer, has been Evaluating the effectiveness of this method in the base of uniformity of the dose distribution in the target volume in breast cancer as an important factor in the effectiveness of treatment by radiation.Materials & Methods: Photon, electron and arc Techniques in radiotherapy have been implemented practically using phantom trunk and EDRII films. At the time of practical Techniques, films were placed between the slice of the phantom and were irradiated under selected conditions and the data of these images are analyzed by MATLAB software.Results: Studies show that as a result of using adjacent fields in whole radiotherapy techniques, Parts of the target volume received dose twice or more than the prescribed dose. Meanwhile, by the photon dose technique, rate of receiving dose is more uniform and closer to the prescribed dose.Conclusion: According to scientific studies done by different protocols in breast radiotherapy, tangential photon technique has very less overlap of the field by comparison to other methods and more uniform dose distribution than the prescribed dose .In The base of this research results can be announced the photon techniques in breast cancer treatment was preferred over other methods.http://journal.fums.ac.ir/browse.php?a_code=A-10-199-1&slc_lang=en&sid=1Keywords: radiotherapy mastectomy Absorption dose linear accelerator Phantom Breast Cancer |
spellingShingle | Sajad Pashton shayesteh Abas Haghparast Masomeh Seidi Behrouz Moradhasel Mostafa Taghi Pour Uniformity of Dose Distribution in Target Volume in Radiotherapy Techniques for Breast after Mastectomy. Journal of Fasa University of Medical Sciences Keywords: radiotherapy mastectomy Absorption dose linear accelerator Phantom Breast Cancer |
title | Uniformity of Dose Distribution in Target Volume in Radiotherapy Techniques for Breast after Mastectomy. |
title_full | Uniformity of Dose Distribution in Target Volume in Radiotherapy Techniques for Breast after Mastectomy. |
title_fullStr | Uniformity of Dose Distribution in Target Volume in Radiotherapy Techniques for Breast after Mastectomy. |
title_full_unstemmed | Uniformity of Dose Distribution in Target Volume in Radiotherapy Techniques for Breast after Mastectomy. |
title_short | Uniformity of Dose Distribution in Target Volume in Radiotherapy Techniques for Breast after Mastectomy. |
title_sort | uniformity of dose distribution in target volume in radiotherapy techniques for breast after mastectomy |
topic | Keywords: radiotherapy mastectomy Absorption dose linear accelerator Phantom Breast Cancer |
url | http://journal.fums.ac.ir/browse.php?a_code=A-10-199-1&slc_lang=en&sid=1 |
work_keys_str_mv | AT sajadpashtonshayesteh uniformityofdosedistributionintargetvolumeinradiotherapytechniquesforbreastaftermastectomy AT abashaghparast uniformityofdosedistributionintargetvolumeinradiotherapytechniquesforbreastaftermastectomy AT masomehseidi uniformityofdosedistributionintargetvolumeinradiotherapytechniquesforbreastaftermastectomy AT behrouzmoradhasel uniformityofdosedistributionintargetvolumeinradiotherapytechniquesforbreastaftermastectomy AT mostafataghipour uniformityofdosedistributionintargetvolumeinradiotherapytechniquesforbreastaftermastectomy |