Uniformity of Dose Distribution in Target Volume in Radiotherapy Techniques for Breast after Mastectomy.

Background & Objective: Radiotherapy has a very special significance in the treatment of cancer. Beam radiation therapy using photons and electrons produced by a linear accelerator is used extensively in the treatment of breast Cancer. In this article, In addition to providing a description of t...

Full description

Bibliographic Details
Main Authors: Sajad Pashton shayesteh, Abas Haghparast, Masomeh Seidi, Behrouz Moradhasel, Mostafa Taghi Pour
Format: Article
Language:fas
Published: Fasa University of Medical Sciences 2014-03-01
Series:Journal of Fasa University of Medical Sciences
Subjects:
Online Access:http://journal.fums.ac.ir/browse.php?a_code=A-10-199-1&slc_lang=en&sid=1
_version_ 1819259105431257088
author Sajad Pashton shayesteh
Abas Haghparast
Masomeh Seidi
Behrouz Moradhasel
Mostafa Taghi Pour
author_facet Sajad Pashton shayesteh
Abas Haghparast
Masomeh Seidi
Behrouz Moradhasel
Mostafa Taghi Pour
author_sort Sajad Pashton shayesteh
collection DOAJ
description Background & Objective: Radiotherapy has a very special significance in the treatment of cancer. Beam radiation therapy using photons and electrons produced by a linear accelerator is used extensively in the treatment of breast Cancer. In this article, In addition to providing a description of three techniques of radiotherapy in the treatment of breast cancer, has been Evaluating the effectiveness of this method in the base of uniformity of the dose distribution in the target volume in breast cancer as an important factor in the effectiveness of treatment by radiation.Materials & Methods: Photon, electron and arc Techniques in radiotherapy have been implemented practically using phantom trunk and EDRII films. At the time of practical Techniques, films were placed between the slice of the phantom and were irradiated under selected conditions and the data of these images are analyzed by MATLAB software.Results: Studies show that as a result of using adjacent fields in whole radiotherapy techniques, Parts of the target volume received dose twice or more than the prescribed dose. Meanwhile, by the photon dose technique, rate of receiving dose is more uniform and closer to the prescribed dose.Conclusion: According to scientific studies done by different protocols in breast radiotherapy, tangential photon technique has very less overlap of the field by comparison to other methods and more uniform dose distribution than the prescribed dose .In The base of this research results can be announced the photon techniques in breast cancer treatment was preferred over other methods.
first_indexed 2024-12-23T19:04:43Z
format Article
id doaj.art-369a083bf11148939ae4fbcf01dbfcd4
institution Directory Open Access Journal
issn 2228-5105
2228-7329
language fas
last_indexed 2024-12-23T19:04:43Z
publishDate 2014-03-01
publisher Fasa University of Medical Sciences
record_format Article
series Journal of Fasa University of Medical Sciences
spelling doaj.art-369a083bf11148939ae4fbcf01dbfcd42022-12-21T17:34:38ZfasFasa University of Medical SciencesJournal of Fasa University of Medical Sciences2228-51052228-73292014-03-0134355362Uniformity of Dose Distribution in Target Volume in Radiotherapy Techniques for Breast after Mastectomy.Sajad Pashton shayesteh 0Abas Haghparast 1Masomeh Seidi2Behrouz Moradhasel3Mostafa Taghi Pour 4 Department of Medical physics, Kermanshah University of Medical Sciences, Kermanshah, Iran Department of Medical physics, Kermanshah University of Medical Sciences, Kermanshah, Iran Instructor, Education Development Center, Hamadan University of Medical Sciences, Hamadan, Iran. Department of Biomedical Engineering, Kermanshah University of Medical Sciences, Kermanshah, Iran. Department of Biomedical Engineering, Kermanshah University of Medical Sciences, Kermanshah, Iran. Background & Objective: Radiotherapy has a very special significance in the treatment of cancer. Beam radiation therapy using photons and electrons produced by a linear accelerator is used extensively in the treatment of breast Cancer. In this article, In addition to providing a description of three techniques of radiotherapy in the treatment of breast cancer, has been Evaluating the effectiveness of this method in the base of uniformity of the dose distribution in the target volume in breast cancer as an important factor in the effectiveness of treatment by radiation.Materials & Methods: Photon, electron and arc Techniques in radiotherapy have been implemented practically using phantom trunk and EDRII films. At the time of practical Techniques, films were placed between the slice of the phantom and were irradiated under selected conditions and the data of these images are analyzed by MATLAB software.Results: Studies show that as a result of using adjacent fields in whole radiotherapy techniques, Parts of the target volume received dose twice or more than the prescribed dose. Meanwhile, by the photon dose technique, rate of receiving dose is more uniform and closer to the prescribed dose.Conclusion: According to scientific studies done by different protocols in breast radiotherapy, tangential photon technique has very less overlap of the field by comparison to other methods and more uniform dose distribution than the prescribed dose .In The base of this research results can be announced the photon techniques in breast cancer treatment was preferred over other methods.http://journal.fums.ac.ir/browse.php?a_code=A-10-199-1&slc_lang=en&sid=1Keywords: radiotherapy mastectomy Absorption dose linear accelerator Phantom Breast Cancer
spellingShingle Sajad Pashton shayesteh
Abas Haghparast
Masomeh Seidi
Behrouz Moradhasel
Mostafa Taghi Pour
Uniformity of Dose Distribution in Target Volume in Radiotherapy Techniques for Breast after Mastectomy.
Journal of Fasa University of Medical Sciences
Keywords: radiotherapy
mastectomy
Absorption dose
linear accelerator
Phantom
Breast Cancer
title Uniformity of Dose Distribution in Target Volume in Radiotherapy Techniques for Breast after Mastectomy.
title_full Uniformity of Dose Distribution in Target Volume in Radiotherapy Techniques for Breast after Mastectomy.
title_fullStr Uniformity of Dose Distribution in Target Volume in Radiotherapy Techniques for Breast after Mastectomy.
title_full_unstemmed Uniformity of Dose Distribution in Target Volume in Radiotherapy Techniques for Breast after Mastectomy.
title_short Uniformity of Dose Distribution in Target Volume in Radiotherapy Techniques for Breast after Mastectomy.
title_sort uniformity of dose distribution in target volume in radiotherapy techniques for breast after mastectomy
topic Keywords: radiotherapy
mastectomy
Absorption dose
linear accelerator
Phantom
Breast Cancer
url http://journal.fums.ac.ir/browse.php?a_code=A-10-199-1&slc_lang=en&sid=1
work_keys_str_mv AT sajadpashtonshayesteh uniformityofdosedistributionintargetvolumeinradiotherapytechniquesforbreastaftermastectomy
AT abashaghparast uniformityofdosedistributionintargetvolumeinradiotherapytechniquesforbreastaftermastectomy
AT masomehseidi uniformityofdosedistributionintargetvolumeinradiotherapytechniquesforbreastaftermastectomy
AT behrouzmoradhasel uniformityofdosedistributionintargetvolumeinradiotherapytechniquesforbreastaftermastectomy
AT mostafataghipour uniformityofdosedistributionintargetvolumeinradiotherapytechniquesforbreastaftermastectomy