Rating of intra-operative neuro-monitoring results in operative correction of the spinal deformities

Purpose of the work was filing the electrophysiological phenomena observed in the process of intra-operative neuromonitoring followed by development of the results’ scale of intra-operative neuro-physiological testing of the pyramidal tract. Materials and мethods. The selection for evaluation includ...

Full description

Bibliographic Details
Main Authors: A. A. Skripnikov, M. S. Saiphutdinov, S. O. Ryabykh, G. A. Krivoruchko, A. P. Shein
Format: Article
Language:Russian
Published: Vreden Russian Research Institute of Traumatology and Orthopedics 2016-06-01
Series:Travmatologiâ i Ortopediâ Rossii
Subjects:
Online Access:https://journal.rniito.org/jour/article/view/5
_version_ 1819127919141715968
author A. A. Skripnikov
M. S. Saiphutdinov
S. O. Ryabykh
G. A. Krivoruchko
A. P. Shein
author_facet A. A. Skripnikov
M. S. Saiphutdinov
S. O. Ryabykh
G. A. Krivoruchko
A. P. Shein
author_sort A. A. Skripnikov
collection DOAJ
description Purpose of the work was filing the electrophysiological phenomena observed in the process of intra-operative neuromonitoring followed by development of the results’ scale of intra-operative neuro-physiological testing of the pyramidal tract. Materials and мethods. The selection for evaluation included data of 147 protocols of intra-operative neuromonitoring in 135 patients (53 males, 82 females), aged from 1 y. 5 m. to 52 years (14,1±0,7 years) with spinal deformities of different etiology who underwent instrumentation spinal correction followed by fixation of thoracic / thoracolumbar spine segments using various variants of internal systems of trans-pedicular fixation. Intra-operative neuro-monitoring was performed using system «ISIS IOM» (Inomed Medizintechnik GmbH, Germany). The changes of motor evoked potentials were evaluated according to this scale. Results. Five types of pyramidal system reaction to operative invasion were revealed. According to neurophysiological criteria three grades of the risk of neurological disorders development during operative spinal deformity correction and, correspondingly, three levels of anxiety for the surgeon were defined. Conclusion. Intra-operative neurophysiological monitoring is the effective highly technological instrument to prevent neurological disorders in the spinal deformity. Offered rating scale of the risk of neurological complications gives the possibility to highlight three levels of anxiety during operative invasion.
first_indexed 2024-12-22T08:19:34Z
format Article
id doaj.art-369bf493da3d4240be7a4b94b3e056fa
institution Directory Open Access Journal
issn 2311-2905
2542-0933
language Russian
last_indexed 2024-12-22T08:19:34Z
publishDate 2016-06-01
publisher Vreden Russian Research Institute of Traumatology and Orthopedics
record_format Article
series Travmatologiâ i Ortopediâ Rossii
spelling doaj.art-369bf493da3d4240be7a4b94b3e056fa2022-12-21T18:32:48ZrusVreden Russian Research Institute of Traumatology and OrthopedicsTravmatologiâ i Ortopediâ Rossii2311-29052542-09332016-06-0104374510.21823/2311-2905-2015-0-4-37-454Rating of intra-operative neuro-monitoring results in operative correction of the spinal deformitiesA. A. Skripnikov0M. S. Saiphutdinov1S. O. Ryabykh2G. A. Krivoruchko3A. P. Shein4Ilizarov Russian Scientific Center «Restorative Traumatology and Orthopedics»Ilizarov Russian Scientific Center «Restorative Traumatology and Orthopedics»Ilizarov Russian Scientific Center «Restorative Traumatology and Orthopedics»Ilizarov Russian Scientific Center «Restorative Traumatology and Orthopedics»Ilizarov Russian Scientific Center «Restorative Traumatology and Orthopedics»Purpose of the work was filing the electrophysiological phenomena observed in the process of intra-operative neuromonitoring followed by development of the results’ scale of intra-operative neuro-physiological testing of the pyramidal tract. Materials and мethods. The selection for evaluation included data of 147 protocols of intra-operative neuromonitoring in 135 patients (53 males, 82 females), aged from 1 y. 5 m. to 52 years (14,1±0,7 years) with spinal deformities of different etiology who underwent instrumentation spinal correction followed by fixation of thoracic / thoracolumbar spine segments using various variants of internal systems of trans-pedicular fixation. Intra-operative neuro-monitoring was performed using system «ISIS IOM» (Inomed Medizintechnik GmbH, Germany). The changes of motor evoked potentials were evaluated according to this scale. Results. Five types of pyramidal system reaction to operative invasion were revealed. According to neurophysiological criteria three grades of the risk of neurological disorders development during operative spinal deformity correction and, correspondingly, three levels of anxiety for the surgeon were defined. Conclusion. Intra-operative neurophysiological monitoring is the effective highly technological instrument to prevent neurological disorders in the spinal deformity. Offered rating scale of the risk of neurological complications gives the possibility to highlight three levels of anxiety during operative invasion.https://journal.rniito.org/jour/article/view/5spinal deformityintra-operative neuro-monitoringpyramidal systemneurological complications
spellingShingle A. A. Skripnikov
M. S. Saiphutdinov
S. O. Ryabykh
G. A. Krivoruchko
A. P. Shein
Rating of intra-operative neuro-monitoring results in operative correction of the spinal deformities
Travmatologiâ i Ortopediâ Rossii
spinal deformity
intra-operative neuro-monitoring
pyramidal system
neurological complications
title Rating of intra-operative neuro-monitoring results in operative correction of the spinal deformities
title_full Rating of intra-operative neuro-monitoring results in operative correction of the spinal deformities
title_fullStr Rating of intra-operative neuro-monitoring results in operative correction of the spinal deformities
title_full_unstemmed Rating of intra-operative neuro-monitoring results in operative correction of the spinal deformities
title_short Rating of intra-operative neuro-monitoring results in operative correction of the spinal deformities
title_sort rating of intra operative neuro monitoring results in operative correction of the spinal deformities
topic spinal deformity
intra-operative neuro-monitoring
pyramidal system
neurological complications
url https://journal.rniito.org/jour/article/view/5
work_keys_str_mv AT aaskripnikov ratingofintraoperativeneuromonitoringresultsinoperativecorrectionofthespinaldeformities
AT mssaiphutdinov ratingofintraoperativeneuromonitoringresultsinoperativecorrectionofthespinaldeformities
AT soryabykh ratingofintraoperativeneuromonitoringresultsinoperativecorrectionofthespinaldeformities
AT gakrivoruchko ratingofintraoperativeneuromonitoringresultsinoperativecorrectionofthespinaldeformities
AT apshein ratingofintraoperativeneuromonitoringresultsinoperativecorrectionofthespinaldeformities