APPLICATION OF QUATERNIONS FOR REFLECTOR PARAMETER

Subject of Research. The paper deals with application of quaternions for optimization of reflector parameters at autocollimation measurements in comparison with a matrix method. Computer-based results on the quaternionic models are presented that have given the possibility to determine conditions o...

Full description

Bibliographic Details
Main Authors: I. A. Konyakhin, V. P. Hoang
Format: Article
Language:English
Published: Saint Petersburg National Research University of Information Technologies, Mechanics and Optics (ITMO University) 2016-09-01
Series:Naučno-tehničeskij Vestnik Informacionnyh Tehnologij, Mehaniki i Optiki
Subjects:
Online Access:http://ntv.ifmo.ru/file/article/16075.pdf
_version_ 1818410375421362176
author I. A. Konyakhin
V. P. Hoang
author_facet I. A. Konyakhin
V. P. Hoang
author_sort I. A. Konyakhin
collection DOAJ
description Subject of Research. The paper deals with application of quaternions for optimization of reflector parameters at autocollimation measurements in comparison with a matrix method. Computer-based results on the quaternionic models are presented that have given the possibility to determine conditions of measurement error reduction in view of apriori information on the rotation axis position. The practical synthesis technique for tetrahedron reflector parameters using found ratios is considered. Method. Originally, received conditions for reduction of autocollimation system measurement error are determined with the use of a matrix method for definition of an angular object position as a set of three equivalent consecutive turns about coordinate axes. At realization of these conditions the numerous recalculation of orientation parameters between various systems of coordinates is necessary that increases complexity and reduces resulting accuracy of autocollimation system at practical measurements. The method of quaternions gives the possibility to analyze the change of an absolute angular position in space, thus, there are conditions of accuracy increase regardless of the used systems of coordinates. Main Results. Researches on the mathematical model have shown, that the orthogonal arrangement of two basic constant directions for autocollimator tetrahedron reflector is optimal with respect to criterion of measurement error reduction at bisection arrangement of actual turn axis against them. Practical Relevance. On the basis of the found ratios between tetrahedron reflector angles and angles of its initial orientation parameters we have developed a practical method of reflector synthesis for autocollimation measurements in case of apriori information on an actual turn axis at monitoring measurements of the shaft or pipelines deformations.
first_indexed 2024-12-14T10:14:31Z
format Article
id doaj.art-36a55180ed3b4c43923dd94a877e1db1
institution Directory Open Access Journal
issn 2226-1494
2500-0373
language English
last_indexed 2024-12-14T10:14:31Z
publishDate 2016-09-01
publisher Saint Petersburg National Research University of Information Technologies, Mechanics and Optics (ITMO University)
record_format Article
series Naučno-tehničeskij Vestnik Informacionnyh Tehnologij, Mehaniki i Optiki
spelling doaj.art-36a55180ed3b4c43923dd94a877e1db12022-12-21T23:06:54ZengSaint Petersburg National Research University of Information Technologies, Mechanics and Optics (ITMO University)Naučno-tehničeskij Vestnik Informacionnyh Tehnologij, Mehaniki i Optiki2226-14942500-03732016-09-0116577377910.17586/2226-1494-2016-16-5-773-779APPLICATION OF QUATERNIONS FOR REFLECTOR PARAMETERI. A. KonyakhinV. P. HoangSubject of Research. The paper deals with application of quaternions for optimization of reflector parameters at autocollimation measurements in comparison with a matrix method. Computer-based results on the quaternionic models are presented that have given the possibility to determine conditions of measurement error reduction in view of apriori information on the rotation axis position. The practical synthesis technique for tetrahedron reflector parameters using found ratios is considered. Method. Originally, received conditions for reduction of autocollimation system measurement error are determined with the use of a matrix method for definition of an angular object position as a set of three equivalent consecutive turns about coordinate axes. At realization of these conditions the numerous recalculation of orientation parameters between various systems of coordinates is necessary that increases complexity and reduces resulting accuracy of autocollimation system at practical measurements. The method of quaternions gives the possibility to analyze the change of an absolute angular position in space, thus, there are conditions of accuracy increase regardless of the used systems of coordinates. Main Results. Researches on the mathematical model have shown, that the orthogonal arrangement of two basic constant directions for autocollimator tetrahedron reflector is optimal with respect to criterion of measurement error reduction at bisection arrangement of actual turn axis against them. Practical Relevance. On the basis of the found ratios between tetrahedron reflector angles and angles of its initial orientation parameters we have developed a practical method of reflector synthesis for autocollimation measurements in case of apriori information on an actual turn axis at monitoring measurements of the shaft or pipelines deformations.http://ntv.ifmo.ru/file/article/16075.pdfquaternionreflectorautocollimatorrotation angles measurement
spellingShingle I. A. Konyakhin
V. P. Hoang
APPLICATION OF QUATERNIONS FOR REFLECTOR PARAMETER
Naučno-tehničeskij Vestnik Informacionnyh Tehnologij, Mehaniki i Optiki
quaternion
reflector
autocollimator
rotation angles measurement
title APPLICATION OF QUATERNIONS FOR REFLECTOR PARAMETER
title_full APPLICATION OF QUATERNIONS FOR REFLECTOR PARAMETER
title_fullStr APPLICATION OF QUATERNIONS FOR REFLECTOR PARAMETER
title_full_unstemmed APPLICATION OF QUATERNIONS FOR REFLECTOR PARAMETER
title_short APPLICATION OF QUATERNIONS FOR REFLECTOR PARAMETER
title_sort application of quaternions for reflector parameter
topic quaternion
reflector
autocollimator
rotation angles measurement
url http://ntv.ifmo.ru/file/article/16075.pdf
work_keys_str_mv AT iakonyakhin applicationofquaternionsforreflectorparameter
AT vphoang applicationofquaternionsforreflectorparameter