The Relationship between Corvis ST Tonometry and Ocular Response Analyzer Measurements in Eyes with Glaucoma.

It is important to compare the results of Corneal Visualization Scheimpflug Technology instrument (CST) measurements and Reichert Ocular Response Analyzer (ORA) parameters. The purpose of the study was to investigate the association between CST measurements and ORA parameters in ninety-five patients...

Full description

Bibliographic Details
Main Authors: Masato Matsuura, Kazunori Hirasawa, Hiroshi Murata, Mieko Yanagisawa, Yoshitaka Nakao, Shunsuke Nakakura, Yoshiaki Kiuchi, Ryo Asaoka
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2016-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC5006993?pdf=render
_version_ 1828762291705741312
author Masato Matsuura
Kazunori Hirasawa
Hiroshi Murata
Mieko Yanagisawa
Yoshitaka Nakao
Shunsuke Nakakura
Yoshiaki Kiuchi
Ryo Asaoka
author_facet Masato Matsuura
Kazunori Hirasawa
Hiroshi Murata
Mieko Yanagisawa
Yoshitaka Nakao
Shunsuke Nakakura
Yoshiaki Kiuchi
Ryo Asaoka
author_sort Masato Matsuura
collection DOAJ
description It is important to compare the results of Corneal Visualization Scheimpflug Technology instrument (CST) measurements and Reichert Ocular Response Analyzer (ORA) parameters. The purpose of the study was to investigate the association between CST measurements and ORA parameters in ninety-five patients with primary open-angle glaucoma. Measurements of CST, ORA, axial length (AL), average corneal curvature (CC), central corneal thickness (CCT) and intraocular pressure (IOP) with Goldmann applanation tonometry (GAT) were carried out. The association between CST and ORA parameters was assessed using linear regression analysis, with model selection based on the second order bias corrected Akaike Information Criterion index. Measurements from ORA (corneal hysteresis [CH] and corneal response factor [CRF]) had high intraclass correlation coefficients (ICC) and low coefficients of variation, but some CST parameters showed much lower reproducibility, namely: A1 length, A2 length, highest concavity time and peak distance. Of 12 CST parameters tested, 8 were significantly correlated with CH and 10 were significantly correlated with CRF, however, the magnitude of the correlation coefficients were weak to moderate at best. The optimal model to explain CH using CST measurements was given by: CH = -76.3 + 4.6*A1 time + 1.9*A2 time + 3.1 * highest concavity deformation amplitude + 0.016*CCT (R2 = 0.67, p <0.001). Similarly, the optimal model for CRF was given by: CRF = -53.5 + 4.2*A1 time + 1.9*A1 length + 20.8*A1 deformation amplitude + 0.8*A2 time + 0.017*CCT (R2 = 0.73, p <0.001). ORA parameters show higher reproducibility than CST measurements. Although many CST parameters are significantly related to ORA parameters, the strengths of these relationships are weak to moderate.
first_indexed 2024-12-11T01:42:12Z
format Article
id doaj.art-36cdac481c104d8eb53ca8cf020cee81
institution Directory Open Access Journal
issn 1932-6203
language English
last_indexed 2024-12-11T01:42:12Z
publishDate 2016-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj.art-36cdac481c104d8eb53ca8cf020cee812022-12-22T01:25:00ZengPublic Library of Science (PLoS)PLoS ONE1932-62032016-01-01118e016174210.1371/journal.pone.0161742The Relationship between Corvis ST Tonometry and Ocular Response Analyzer Measurements in Eyes with Glaucoma.Masato MatsuuraKazunori HirasawaHiroshi MurataMieko YanagisawaYoshitaka NakaoShunsuke NakakuraYoshiaki KiuchiRyo AsaokaIt is important to compare the results of Corneal Visualization Scheimpflug Technology instrument (CST) measurements and Reichert Ocular Response Analyzer (ORA) parameters. The purpose of the study was to investigate the association between CST measurements and ORA parameters in ninety-five patients with primary open-angle glaucoma. Measurements of CST, ORA, axial length (AL), average corneal curvature (CC), central corneal thickness (CCT) and intraocular pressure (IOP) with Goldmann applanation tonometry (GAT) were carried out. The association between CST and ORA parameters was assessed using linear regression analysis, with model selection based on the second order bias corrected Akaike Information Criterion index. Measurements from ORA (corneal hysteresis [CH] and corneal response factor [CRF]) had high intraclass correlation coefficients (ICC) and low coefficients of variation, but some CST parameters showed much lower reproducibility, namely: A1 length, A2 length, highest concavity time and peak distance. Of 12 CST parameters tested, 8 were significantly correlated with CH and 10 were significantly correlated with CRF, however, the magnitude of the correlation coefficients were weak to moderate at best. The optimal model to explain CH using CST measurements was given by: CH = -76.3 + 4.6*A1 time + 1.9*A2 time + 3.1 * highest concavity deformation amplitude + 0.016*CCT (R2 = 0.67, p <0.001). Similarly, the optimal model for CRF was given by: CRF = -53.5 + 4.2*A1 time + 1.9*A1 length + 20.8*A1 deformation amplitude + 0.8*A2 time + 0.017*CCT (R2 = 0.73, p <0.001). ORA parameters show higher reproducibility than CST measurements. Although many CST parameters are significantly related to ORA parameters, the strengths of these relationships are weak to moderate.http://europepmc.org/articles/PMC5006993?pdf=render
spellingShingle Masato Matsuura
Kazunori Hirasawa
Hiroshi Murata
Mieko Yanagisawa
Yoshitaka Nakao
Shunsuke Nakakura
Yoshiaki Kiuchi
Ryo Asaoka
The Relationship between Corvis ST Tonometry and Ocular Response Analyzer Measurements in Eyes with Glaucoma.
PLoS ONE
title The Relationship between Corvis ST Tonometry and Ocular Response Analyzer Measurements in Eyes with Glaucoma.
title_full The Relationship between Corvis ST Tonometry and Ocular Response Analyzer Measurements in Eyes with Glaucoma.
title_fullStr The Relationship between Corvis ST Tonometry and Ocular Response Analyzer Measurements in Eyes with Glaucoma.
title_full_unstemmed The Relationship between Corvis ST Tonometry and Ocular Response Analyzer Measurements in Eyes with Glaucoma.
title_short The Relationship between Corvis ST Tonometry and Ocular Response Analyzer Measurements in Eyes with Glaucoma.
title_sort relationship between corvis st tonometry and ocular response analyzer measurements in eyes with glaucoma
url http://europepmc.org/articles/PMC5006993?pdf=render
work_keys_str_mv AT masatomatsuura therelationshipbetweencorvissttonometryandocularresponseanalyzermeasurementsineyeswithglaucoma
AT kazunorihirasawa therelationshipbetweencorvissttonometryandocularresponseanalyzermeasurementsineyeswithglaucoma
AT hiroshimurata therelationshipbetweencorvissttonometryandocularresponseanalyzermeasurementsineyeswithglaucoma
AT miekoyanagisawa therelationshipbetweencorvissttonometryandocularresponseanalyzermeasurementsineyeswithglaucoma
AT yoshitakanakao therelationshipbetweencorvissttonometryandocularresponseanalyzermeasurementsineyeswithglaucoma
AT shunsukenakakura therelationshipbetweencorvissttonometryandocularresponseanalyzermeasurementsineyeswithglaucoma
AT yoshiakikiuchi therelationshipbetweencorvissttonometryandocularresponseanalyzermeasurementsineyeswithglaucoma
AT ryoasaoka therelationshipbetweencorvissttonometryandocularresponseanalyzermeasurementsineyeswithglaucoma
AT masatomatsuura relationshipbetweencorvissttonometryandocularresponseanalyzermeasurementsineyeswithglaucoma
AT kazunorihirasawa relationshipbetweencorvissttonometryandocularresponseanalyzermeasurementsineyeswithglaucoma
AT hiroshimurata relationshipbetweencorvissttonometryandocularresponseanalyzermeasurementsineyeswithglaucoma
AT miekoyanagisawa relationshipbetweencorvissttonometryandocularresponseanalyzermeasurementsineyeswithglaucoma
AT yoshitakanakao relationshipbetweencorvissttonometryandocularresponseanalyzermeasurementsineyeswithglaucoma
AT shunsukenakakura relationshipbetweencorvissttonometryandocularresponseanalyzermeasurementsineyeswithglaucoma
AT yoshiakikiuchi relationshipbetweencorvissttonometryandocularresponseanalyzermeasurementsineyeswithglaucoma
AT ryoasaoka relationshipbetweencorvissttonometryandocularresponseanalyzermeasurementsineyeswithglaucoma