Effect of Denture Cleanser on the Physico-Mechanical Properties of Injection-Molded Thermoplastic Polyamides Denture Base Material: A preliminary Study

Objectives: This study aimed to assess the color stability, surface roughness, and flexural properties of the injection-molded thermoplastic polyamide Vertex ThermoSens denture base resin following a 3-minute immersion in Polident 3-minute denture cleanser. Methods: Sixty specimens (Vertex ThermoSen...

Full description

Bibliographic Details
Main Authors: Hazem Mofreh Altarawneh, Mohammed Nasser Alhajj, Nosizana Mohd Salleh, Aeman H. H. Elkezza, Wan Adida Mahmood
Format: Article
Language:English
Published: University of Zagreb. School of Dental Medicine 2023-01-01
Series:Acta Stomatologica Croatica
Subjects:
Online Access:https://hrcak.srce.hr/file/450650
_version_ 1797206232801476608
author Hazem Mofreh Altarawneh
Mohammed Nasser Alhajj
Nosizana Mohd Salleh
Aeman H. H. Elkezza
Wan Adida Mahmood
author_facet Hazem Mofreh Altarawneh
Mohammed Nasser Alhajj
Nosizana Mohd Salleh
Aeman H. H. Elkezza
Wan Adida Mahmood
author_sort Hazem Mofreh Altarawneh
collection DOAJ
description Objectives: This study aimed to assess the color stability, surface roughness, and flexural properties of the injection-molded thermoplastic polyamide Vertex ThermoSens denture base resin following a 3-minute immersion in Polident 3-minute denture cleanser. Methods: Sixty specimens (Vertex ThermoSens) were processed and divided into two main groups (n = 30) based on the type of test. Group 1 was further subdivided into two subgroups (n = 15): the control group immersed in distilled water (G1DW) and the test group immersed in Polident cleanser solution (G1PD). Group 2 was divided into three subgroups: a non-immersed group (G2None), a group immersed in distilled water (G2DW), and a group immersed in Polident cleanser solution (G2PD). Color change (∆E) and surface roughness measurements were conducted for group 1, and flexural modulus (E) test was performed for group 2. The CIE Lab* formula was utilized to calculate ∆E. An optical 3D surface analyzer and a three-point bending test were employed for surface roughness and E assessments, respectively. Data were subjected to statistical analysis using a paired-sample t-test for differences within each group before and after immersion. Furthermore, independent-sample t-tests and one-way ANOVA were conducted to analyze differences between groups. A significance level of P < 0.05 was considered. Results: The results revealed a slight, statistically insignificant (P > 0.05) ∆E in all color components (L*, a*, b*) after immersion in distilled water. However, after immersion in the denture cleanser, only the L* component exhibited a statistically significant ∆E (P = 0.002), which was slight in magnitude. Additionally, a significant difference was found in the ∆E between G1DW and G1PD, with G1PD showing a higher change (P = 0.007). A significant increase in surface roughness after immersion was observed in G1PD (P = 0.017), with a notable difference between G1DW and G Conclusion: Denture cleansers have the potential to modify the properties of thermoplastic polyamide resin. Further research is needed to explore the clinical implications of these observed changes on denture performance. 1PD. However, the E remained unaffected (P = 0.537).
first_indexed 2024-04-24T09:03:45Z
format Article
id doaj.art-372e0d5f724e46ddad7ed1df4545a467
institution Directory Open Access Journal
issn 0001-7019
1846-0410
language English
last_indexed 2024-04-24T09:03:45Z
publishDate 2023-01-01
publisher University of Zagreb. School of Dental Medicine
record_format Article
series Acta Stomatologica Croatica
spelling doaj.art-372e0d5f724e46ddad7ed1df4545a4672024-04-15T19:10:59ZengUniversity of Zagreb. School of Dental MedicineActa Stomatologica Croatica0001-70191846-04102023-01-0157432933810.15644/asc57/4/4Effect of Denture Cleanser on the Physico-Mechanical Properties of Injection-Molded Thermoplastic Polyamides Denture Base Material: A preliminary StudyHazem Mofreh Altarawneh0Mohammed Nasser Alhajj1Nosizana Mohd Salleh2Aeman H. H. Elkezza3Wan Adida Mahmood4Centre of Restorative Studies Faculty of Dentistry, University Teknologi MARA, Sungai Buloh, Jalan Hospital, Sungai Buloh, Selangor, MalaysiaDepartment of Restorative Dentistry, Faculty of Dentistry, Universiti Malaya, Kuala Lumpur, Federal Territory of Kuala Lumpur, MalaysiaDepartment of Restorative Dentistry, Faculty of Dentistry, Universiti Malaya, Kuala Lumpur, Federal Territory of Kuala Lumpur, MalaysiaDepartment of Restorative Dentistry, Faculty of Dentistry, Universiti Malaya, Kuala Lumpur, Federal Territory of Kuala Lumpur, MalaysiaFaculty of Dentistry, SEGI university, Jalan Teknologi, Kota Damansara, Petaling Jaya, Selangor, MalaysiaObjectives: This study aimed to assess the color stability, surface roughness, and flexural properties of the injection-molded thermoplastic polyamide Vertex ThermoSens denture base resin following a 3-minute immersion in Polident 3-minute denture cleanser. Methods: Sixty specimens (Vertex ThermoSens) were processed and divided into two main groups (n = 30) based on the type of test. Group 1 was further subdivided into two subgroups (n = 15): the control group immersed in distilled water (G1DW) and the test group immersed in Polident cleanser solution (G1PD). Group 2 was divided into three subgroups: a non-immersed group (G2None), a group immersed in distilled water (G2DW), and a group immersed in Polident cleanser solution (G2PD). Color change (∆E) and surface roughness measurements were conducted for group 1, and flexural modulus (E) test was performed for group 2. The CIE Lab* formula was utilized to calculate ∆E. An optical 3D surface analyzer and a three-point bending test were employed for surface roughness and E assessments, respectively. Data were subjected to statistical analysis using a paired-sample t-test for differences within each group before and after immersion. Furthermore, independent-sample t-tests and one-way ANOVA were conducted to analyze differences between groups. A significance level of P < 0.05 was considered. Results: The results revealed a slight, statistically insignificant (P > 0.05) ∆E in all color components (L*, a*, b*) after immersion in distilled water. However, after immersion in the denture cleanser, only the L* component exhibited a statistically significant ∆E (P = 0.002), which was slight in magnitude. Additionally, a significant difference was found in the ∆E between G1DW and G1PD, with G1PD showing a higher change (P = 0.007). A significant increase in surface roughness after immersion was observed in G1PD (P = 0.017), with a notable difference between G1DW and G Conclusion: Denture cleansers have the potential to modify the properties of thermoplastic polyamide resin. Further research is needed to explore the clinical implications of these observed changes on denture performance. 1PD. However, the E remained unaffected (P = 0.537).https://hrcak.srce.hr/file/450650Denture CleansersDenture BasesNylonsColorSurface PropertiesFlexural Strength
spellingShingle Hazem Mofreh Altarawneh
Mohammed Nasser Alhajj
Nosizana Mohd Salleh
Aeman H. H. Elkezza
Wan Adida Mahmood
Effect of Denture Cleanser on the Physico-Mechanical Properties of Injection-Molded Thermoplastic Polyamides Denture Base Material: A preliminary Study
Acta Stomatologica Croatica
Denture Cleansers
Denture Bases
Nylons
Color
Surface Properties
Flexural Strength
title Effect of Denture Cleanser on the Physico-Mechanical Properties of Injection-Molded Thermoplastic Polyamides Denture Base Material: A preliminary Study
title_full Effect of Denture Cleanser on the Physico-Mechanical Properties of Injection-Molded Thermoplastic Polyamides Denture Base Material: A preliminary Study
title_fullStr Effect of Denture Cleanser on the Physico-Mechanical Properties of Injection-Molded Thermoplastic Polyamides Denture Base Material: A preliminary Study
title_full_unstemmed Effect of Denture Cleanser on the Physico-Mechanical Properties of Injection-Molded Thermoplastic Polyamides Denture Base Material: A preliminary Study
title_short Effect of Denture Cleanser on the Physico-Mechanical Properties of Injection-Molded Thermoplastic Polyamides Denture Base Material: A preliminary Study
title_sort effect of denture cleanser on the physico mechanical properties of injection molded thermoplastic polyamides denture base material a preliminary study
topic Denture Cleansers
Denture Bases
Nylons
Color
Surface Properties
Flexural Strength
url https://hrcak.srce.hr/file/450650
work_keys_str_mv AT hazemmofrehaltarawneh effectofdenturecleanseronthephysicomechanicalpropertiesofinjectionmoldedthermoplasticpolyamidesdenturebasematerialapreliminarystudy
AT mohammednasseralhajj effectofdenturecleanseronthephysicomechanicalpropertiesofinjectionmoldedthermoplasticpolyamidesdenturebasematerialapreliminarystudy
AT nosizanamohdsalleh effectofdenturecleanseronthephysicomechanicalpropertiesofinjectionmoldedthermoplasticpolyamidesdenturebasematerialapreliminarystudy
AT aemanhhelkezza effectofdenturecleanseronthephysicomechanicalpropertiesofinjectionmoldedthermoplasticpolyamidesdenturebasematerialapreliminarystudy
AT wanadidamahmood effectofdenturecleanseronthephysicomechanicalpropertiesofinjectionmoldedthermoplasticpolyamidesdenturebasematerialapreliminarystudy