A case of supraventricular tachycardia misdiagnosis after dual‐chamber implantable cardioverter defibrillator implantation with His bundle pacing

Abstract The combined use of an implantable cardioverter defibrillator (ICD) and His bundle pacing (HBP) is believed to benefit patients with dilated cardiomyopathy (DCM) and atrial fibrillation but needs more guidance built on clinical experience. A patient who had an implanted dual‐chamber ICD wit...

Full description

Bibliographic Details
Main Authors: Xianchao Sun, Yue Huang
Format: Article
Language:English
Published: Wiley 2023-05-01
Series:Annals of Noninvasive Electrocardiology
Subjects:
Online Access:https://doi.org/10.1111/anec.13042
_version_ 1827944397390479360
author Xianchao Sun
Yue Huang
author_facet Xianchao Sun
Yue Huang
author_sort Xianchao Sun
collection DOAJ
description Abstract The combined use of an implantable cardioverter defibrillator (ICD) and His bundle pacing (HBP) is believed to benefit patients with dilated cardiomyopathy (DCM) and atrial fibrillation but needs more guidance built on clinical experience. A patient who had an implanted dual‐chamber ICD with HBP presented to our hospital with DCM and atrial fibrillation. In the present case, the criteria for differential diagnosis were set as “if all,” which requires matching the morphological template, sudden onset, and interval stability. Ventricular tachycardia (VT) was misdiagnosed as supraventricular tachycardia due to morphological matching to sinus tachycardia. The misdiagnosis and mistaken VT treatment(ICD adaptive treatment) highlight the importance of personalized settings for differential diagnosis to avoid such a misdiagnosis or omission.
first_indexed 2024-03-13T10:28:38Z
format Article
id doaj.art-37a2541cff0c4a4fb8430c745bf0860f
institution Directory Open Access Journal
issn 1082-720X
1542-474X
language English
last_indexed 2024-03-13T10:28:38Z
publishDate 2023-05-01
publisher Wiley
record_format Article
series Annals of Noninvasive Electrocardiology
spelling doaj.art-37a2541cff0c4a4fb8430c745bf0860f2023-05-19T03:57:51ZengWileyAnnals of Noninvasive Electrocardiology1082-720X1542-474X2023-05-01283n/an/a10.1111/anec.13042A case of supraventricular tachycardia misdiagnosis after dual‐chamber implantable cardioverter defibrillator implantation with His bundle pacingXianchao Sun0Yue Huang1First Hospital of Jiaxing Zhejiang ChinaFirst Hospital of Jiaxing Zhejiang ChinaAbstract The combined use of an implantable cardioverter defibrillator (ICD) and His bundle pacing (HBP) is believed to benefit patients with dilated cardiomyopathy (DCM) and atrial fibrillation but needs more guidance built on clinical experience. A patient who had an implanted dual‐chamber ICD with HBP presented to our hospital with DCM and atrial fibrillation. In the present case, the criteria for differential diagnosis were set as “if all,” which requires matching the morphological template, sudden onset, and interval stability. Ventricular tachycardia (VT) was misdiagnosed as supraventricular tachycardia due to morphological matching to sinus tachycardia. The misdiagnosis and mistaken VT treatment(ICD adaptive treatment) highlight the importance of personalized settings for differential diagnosis to avoid such a misdiagnosis or omission.https://doi.org/10.1111/anec.13042atrial fibrillationHis bundle packingimplantable cardioverter defibrillatorsupraventricular tachycardiaventricular tachycardia
spellingShingle Xianchao Sun
Yue Huang
A case of supraventricular tachycardia misdiagnosis after dual‐chamber implantable cardioverter defibrillator implantation with His bundle pacing
Annals of Noninvasive Electrocardiology
atrial fibrillation
His bundle packing
implantable cardioverter defibrillator
supraventricular tachycardia
ventricular tachycardia
title A case of supraventricular tachycardia misdiagnosis after dual‐chamber implantable cardioverter defibrillator implantation with His bundle pacing
title_full A case of supraventricular tachycardia misdiagnosis after dual‐chamber implantable cardioverter defibrillator implantation with His bundle pacing
title_fullStr A case of supraventricular tachycardia misdiagnosis after dual‐chamber implantable cardioverter defibrillator implantation with His bundle pacing
title_full_unstemmed A case of supraventricular tachycardia misdiagnosis after dual‐chamber implantable cardioverter defibrillator implantation with His bundle pacing
title_short A case of supraventricular tachycardia misdiagnosis after dual‐chamber implantable cardioverter defibrillator implantation with His bundle pacing
title_sort case of supraventricular tachycardia misdiagnosis after dual chamber implantable cardioverter defibrillator implantation with his bundle pacing
topic atrial fibrillation
His bundle packing
implantable cardioverter defibrillator
supraventricular tachycardia
ventricular tachycardia
url https://doi.org/10.1111/anec.13042
work_keys_str_mv AT xianchaosun acaseofsupraventriculartachycardiamisdiagnosisafterdualchamberimplantablecardioverterdefibrillatorimplantationwithhisbundlepacing
AT yuehuang acaseofsupraventriculartachycardiamisdiagnosisafterdualchamberimplantablecardioverterdefibrillatorimplantationwithhisbundlepacing
AT xianchaosun caseofsupraventriculartachycardiamisdiagnosisafterdualchamberimplantablecardioverterdefibrillatorimplantationwithhisbundlepacing
AT yuehuang caseofsupraventriculartachycardiamisdiagnosisafterdualchamberimplantablecardioverterdefibrillatorimplantationwithhisbundlepacing