Quality control in blood bank Hospital Abel Santamaría Cuadrado

Introduction: The safety of blood products depends to a large extent on blood donor selection and the reliable performance of laboratory tests. Objective: To evaluate the results of the laboratory tests in the quality control in the blood bank.   Methods: a descriptive and cross-sectional study th...

Full description

Bibliographic Details
Main Authors: Maday Padrino González, Silvia María Melians Abreu, Lisset León Amado, Dianelys Díaz Padilla
Format: Article
Language:Spanish
Published: ECIMED 2017-03-01
Series:Revista de Ciencias Médicas de Pinar del Río
Subjects:
Online Access:http://www.revcmpinar.sld.cu/index.php/publicaciones/article/view/2663
_version_ 1828487133842636800
author Maday Padrino González
Silvia María Melians Abreu
Lisset León Amado
Dianelys Díaz Padilla
author_facet Maday Padrino González
Silvia María Melians Abreu
Lisset León Amado
Dianelys Díaz Padilla
author_sort Maday Padrino González
collection DOAJ
description Introduction: The safety of blood products depends to a large extent on blood donor selection and the reliable performance of laboratory tests. Objective: To evaluate the results of the laboratory tests in the quality control in the blood bank.   Methods: a descriptive and cross-sectional study that was carried out including the data obtained from the registers of donation, reception and releases of blood batches from january 2014 october 2015 at the Department of Blood Bank belonging to Abel Santamaria Cuadrado General Teaching Hospital. The results of the initial screening of infectious markers, laboratory examinations carried out following the quality assurance of the components obtained and the non-compulsory loss within the process were evaluated. Results: 8079 donations were processed, predominantly male (93.7%). 3.3% of donors were rejected for low hemoglobin, 2% for positivity in initial screening for hepatitis C antibodies as the most common cause. Laboratory tests were performed on 4.7% of the total annual production; the most studied component was concentrated erythrocytes for 2.1%. There were variations in the number of leukocytes and erythrocytes in the platelet and plasma concentrate, lipemia predominated as non-obligatory low     Conclusion: to emphasize the systematization of promotion work to reach voluntary blood donation, the quality of blood donor selection, food education and the systematic screening of donors to improve these results.
first_indexed 2024-12-11T09:45:17Z
format Article
id doaj.art-37e2ecc2ddb742919531cfa243ad00a2
institution Directory Open Access Journal
issn 1561-3194
language Spanish
last_indexed 2024-12-11T09:45:17Z
publishDate 2017-03-01
publisher ECIMED
record_format Article
series Revista de Ciencias Médicas de Pinar del Río
spelling doaj.art-37e2ecc2ddb742919531cfa243ad00a22022-12-22T01:12:34ZspaECIMEDRevista de Ciencias Médicas de Pinar del Río1561-31942017-03-0121125341422Quality control in blood bank Hospital Abel Santamaría CuadradoMaday Padrino González0Silvia María Melians Abreu1Lisset León Amado2Dianelys Díaz Padilla3Hospital General Docente¨Abel Santamaría Cuadrado¨Hospital General Docente¨Abel Santamaría Cuadrado¨Hospital General Docente¨Abel Santamaría Cuadrado¨Hospital León Cuervo RubioIntroduction: The safety of blood products depends to a large extent on blood donor selection and the reliable performance of laboratory tests. Objective: To evaluate the results of the laboratory tests in the quality control in the blood bank.   Methods: a descriptive and cross-sectional study that was carried out including the data obtained from the registers of donation, reception and releases of blood batches from january 2014 october 2015 at the Department of Blood Bank belonging to Abel Santamaria Cuadrado General Teaching Hospital. The results of the initial screening of infectious markers, laboratory examinations carried out following the quality assurance of the components obtained and the non-compulsory loss within the process were evaluated. Results: 8079 donations were processed, predominantly male (93.7%). 3.3% of donors were rejected for low hemoglobin, 2% for positivity in initial screening for hepatitis C antibodies as the most common cause. Laboratory tests were performed on 4.7% of the total annual production; the most studied component was concentrated erythrocytes for 2.1%. There were variations in the number of leukocytes and erythrocytes in the platelet and plasma concentrate, lipemia predominated as non-obligatory low     Conclusion: to emphasize the systematization of promotion work to reach voluntary blood donation, the quality of blood donor selection, food education and the systematic screening of donors to improve these results.http://www.revcmpinar.sld.cu/index.php/publicaciones/article/view/2663BIOENSAYOCONTROL DE CALIDADDONANTES DE SANGRELABORATORIOSTRANSFUSIÓN DE COMPONENTES SANGUÍNEOS
spellingShingle Maday Padrino González
Silvia María Melians Abreu
Lisset León Amado
Dianelys Díaz Padilla
Quality control in blood bank Hospital Abel Santamaría Cuadrado
Revista de Ciencias Médicas de Pinar del Río
BIOENSAYO
CONTROL DE CALIDAD
DONANTES DE SANGRE
LABORATORIOS
TRANSFUSIÓN DE COMPONENTES SANGUÍNEOS
title Quality control in blood bank Hospital Abel Santamaría Cuadrado
title_full Quality control in blood bank Hospital Abel Santamaría Cuadrado
title_fullStr Quality control in blood bank Hospital Abel Santamaría Cuadrado
title_full_unstemmed Quality control in blood bank Hospital Abel Santamaría Cuadrado
title_short Quality control in blood bank Hospital Abel Santamaría Cuadrado
title_sort quality control in blood bank hospital abel santamaria cuadrado
topic BIOENSAYO
CONTROL DE CALIDAD
DONANTES DE SANGRE
LABORATORIOS
TRANSFUSIÓN DE COMPONENTES SANGUÍNEOS
url http://www.revcmpinar.sld.cu/index.php/publicaciones/article/view/2663
work_keys_str_mv AT madaypadrinogonzalez qualitycontrolinbloodbankhospitalabelsantamariacuadrado
AT silviamariameliansabreu qualitycontrolinbloodbankhospitalabelsantamariacuadrado
AT lissetleonamado qualitycontrolinbloodbankhospitalabelsantamariacuadrado
AT dianelysdiazpadilla qualitycontrolinbloodbankhospitalabelsantamariacuadrado