An automated mammogram classification system using modified support vector machine

Aderonke Anthonia Kayode,1 Noah Oluwatobi Akande,1 Adekanmi Adeyinka Adegun,1 Marion Olubunmi Adebiyi21Computer Science Department, Landmark University, Omu-Aran, Kwara State, Nigeria; 2Department of Computer and Information Sciences, Covenant University, Ota, Ogun State, NigeriaPurpose: Breast canc...

Full description

Bibliographic Details
Main Authors: Kayode AA, Akande NO, Adegun AA, Adebiyi MO
Format: Article
Language:English
Published: Dove Medical Press 2019-08-01
Series:Medical Devices: Evidence and Research
Subjects:
Online Access:https://www.dovepress.com/an-automated-mammogram-classification-system-using-modified-support-ve-peer-reviewed-article-MDER
_version_ 1818854027454054400
author Kayode AA
Akande NO
Adegun AA
Adebiyi MO
author_facet Kayode AA
Akande NO
Adegun AA
Adebiyi MO
author_sort Kayode AA
collection DOAJ
description Aderonke Anthonia Kayode,1 Noah Oluwatobi Akande,1 Adekanmi Adeyinka Adegun,1 Marion Olubunmi Adebiyi21Computer Science Department, Landmark University, Omu-Aran, Kwara State, Nigeria; 2Department of Computer and Information Sciences, Covenant University, Ota, Ogun State, NigeriaPurpose: Breast cancer remains a serious public health problem that results in the loss of lives among women. However, early detection of its signs increases treatment options and the likelihood of cure. Although mammography has been established to be a proven technique of examining symptoms of cancer in mammograms, the manual observation by radiologists is demanding and often prone to diagnostic errors. Therefore, computer aided diagnosis (CADx) systems could be a viable alternative that could facilitate and ease cancer diagnosis process; hence this study.Methodology: The inputs to the proposed model are raw mammograms downloaded from the Mammographic Image Analysis Society database. Prior to the classification, the raw mammograms were preprocessed. Then, gray level co-occurrence matrix was used to extract fifteen textural features from the mammograms at four different angular directions: θ={0°, 45°, 90°, 135°}, and two distances: D={1,2}. Afterwards, a two-stage support vector machine was used to classify the mammograms as normal, benign and malignant.Results: All of the 37 normal images used as test data were classified as normal (no false positive) and all 41 abnormal images were correctly classified to be abnormal (no false negative), meaning that the sensitivity and specificity of the model in detecting abnormality is 100%. After the detection of abnormality, the system further classified the abnormality on the mammograms to be either “benign” or “malignant”. Out of 23 benign images, 21 were truly classified as benign. Also, out of 18 malignant images, 17 were truly classified to be malignant. From these findings, the sensitivity, specificity, positive predictive value, and negative predictive value of the system are 94.4%, 91.3%, 89.5%, and 95.5%, respectively.Conclusion: This article has further affirmed the prowess of automated CADx systems as a viable tool that could facilitate breast cancer diagnosis by radiologists.Keywords: cancer diagnosis, CADx systems, radiologists, diagnostic errors, GLCM
first_indexed 2024-12-19T07:46:11Z
format Article
id doaj.art-38c16044dfdf48f28c0f693ffaeeade9
institution Directory Open Access Journal
issn 1179-1470
language English
last_indexed 2024-12-19T07:46:11Z
publishDate 2019-08-01
publisher Dove Medical Press
record_format Article
series Medical Devices: Evidence and Research
spelling doaj.art-38c16044dfdf48f28c0f693ffaeeade92022-12-21T20:30:18ZengDove Medical PressMedical Devices: Evidence and Research1179-14702019-08-01Volume 1227528447800An automated mammogram classification system using modified support vector machineKayode AAAkande NOAdegun AAAdebiyi MOAderonke Anthonia Kayode,1 Noah Oluwatobi Akande,1 Adekanmi Adeyinka Adegun,1 Marion Olubunmi Adebiyi21Computer Science Department, Landmark University, Omu-Aran, Kwara State, Nigeria; 2Department of Computer and Information Sciences, Covenant University, Ota, Ogun State, NigeriaPurpose: Breast cancer remains a serious public health problem that results in the loss of lives among women. However, early detection of its signs increases treatment options and the likelihood of cure. Although mammography has been established to be a proven technique of examining symptoms of cancer in mammograms, the manual observation by radiologists is demanding and often prone to diagnostic errors. Therefore, computer aided diagnosis (CADx) systems could be a viable alternative that could facilitate and ease cancer diagnosis process; hence this study.Methodology: The inputs to the proposed model are raw mammograms downloaded from the Mammographic Image Analysis Society database. Prior to the classification, the raw mammograms were preprocessed. Then, gray level co-occurrence matrix was used to extract fifteen textural features from the mammograms at four different angular directions: θ={0°, 45°, 90°, 135°}, and two distances: D={1,2}. Afterwards, a two-stage support vector machine was used to classify the mammograms as normal, benign and malignant.Results: All of the 37 normal images used as test data were classified as normal (no false positive) and all 41 abnormal images were correctly classified to be abnormal (no false negative), meaning that the sensitivity and specificity of the model in detecting abnormality is 100%. After the detection of abnormality, the system further classified the abnormality on the mammograms to be either “benign” or “malignant”. Out of 23 benign images, 21 were truly classified as benign. Also, out of 18 malignant images, 17 were truly classified to be malignant. From these findings, the sensitivity, specificity, positive predictive value, and negative predictive value of the system are 94.4%, 91.3%, 89.5%, and 95.5%, respectively.Conclusion: This article has further affirmed the prowess of automated CADx systems as a viable tool that could facilitate breast cancer diagnosis by radiologists.Keywords: cancer diagnosis, CADx systems, radiologists, diagnostic errors, GLCMhttps://www.dovepress.com/an-automated-mammogram-classification-system-using-modified-support-ve-peer-reviewed-article-MDERCancer diagnosisCAD systemsRadiologistsDiagnostic errorsGray level co-occurrence matrix
spellingShingle Kayode AA
Akande NO
Adegun AA
Adebiyi MO
An automated mammogram classification system using modified support vector machine
Medical Devices: Evidence and Research
Cancer diagnosis
CAD systems
Radiologists
Diagnostic errors
Gray level co-occurrence matrix
title An automated mammogram classification system using modified support vector machine
title_full An automated mammogram classification system using modified support vector machine
title_fullStr An automated mammogram classification system using modified support vector machine
title_full_unstemmed An automated mammogram classification system using modified support vector machine
title_short An automated mammogram classification system using modified support vector machine
title_sort automated mammogram classification system using modified support vector machine
topic Cancer diagnosis
CAD systems
Radiologists
Diagnostic errors
Gray level co-occurrence matrix
url https://www.dovepress.com/an-automated-mammogram-classification-system-using-modified-support-ve-peer-reviewed-article-MDER
work_keys_str_mv AT kayodeaa anautomatedmammogramclassificationsystemusingmodifiedsupportvectormachine
AT akandeno anautomatedmammogramclassificationsystemusingmodifiedsupportvectormachine
AT adegunaa anautomatedmammogramclassificationsystemusingmodifiedsupportvectormachine
AT adebiyimo anautomatedmammogramclassificationsystemusingmodifiedsupportvectormachine
AT kayodeaa automatedmammogramclassificationsystemusingmodifiedsupportvectormachine
AT akandeno automatedmammogramclassificationsystemusingmodifiedsupportvectormachine
AT adegunaa automatedmammogramclassificationsystemusingmodifiedsupportvectormachine
AT adebiyimo automatedmammogramclassificationsystemusingmodifiedsupportvectormachine