Evaluation of optical coherence tomography combined with ophthalmic B-type ultrasound in fundus examination before cataract surgeries

AIM:To investigate the clinical value of optical coherence tomography(OCT)combined with ophthalmic B-type ultrasound in fundus examination before cataract surgeries.<p>METHODS:Conventional ophthalmoscope, ophthalmic B-type ultrasound and OCT were used to exam the fundus of 176 cataract patient...

Full description

Bibliographic Details
Main Authors: Dan Liu, Yu-Lin Tao, Li-Ming Tao
Format: Article
Language:English
Published: Press of International Journal of Ophthalmology (IJO PRESS) 2015-10-01
Series:Guoji Yanke Zazhi
Subjects:
Online Access:http://ies.ijo.cn/cn_publish/2015/10/201510041.pdf
_version_ 1818366379341905920
author Dan Liu
Yu-Lin Tao
Li-Ming Tao
author_facet Dan Liu
Yu-Lin Tao
Li-Ming Tao
author_sort Dan Liu
collection DOAJ
description AIM:To investigate the clinical value of optical coherence tomography(OCT)combined with ophthalmic B-type ultrasound in fundus examination before cataract surgeries.<p>METHODS:Conventional ophthalmoscope, ophthalmic B-type ultrasound and OCT were used to exam the fundus of 176 cataract patients(278 eyes). The positive rate of fundus diseases by the three methods was calculated, and then McNemar test was used to analyze the data in pairs and the values of the three methods on diagnosis of fundus diseases were investigated.<p>RESULTS:Thirty-two eyes were diagnosed with fundus diseases by conventional ophthalmoscope with positive rate of 11.5%, 18 eyes(6.5%)by ophthalmic B-type ultrasound, 6 eyes(2.2%)of those 18 eyes were serious lens turbidity. Fifty-one eyes(18.3%)were diagnosed with fundus diseases by OCT and 57 eyes(20.5%)by OCT combined with ophthalmic B-type ultrasound. The positive rate of fundus disease detected by OCT had significant difference at the level of α=0.05 compared with those by ophthalmic B-type ultrasound, conventional ophthalmoscope and OCT combined with ophthalmic B-type ultrasound. <p>CONCLUSION:OCT is more valuable and more sensitive on detecting macular diseases than the other two. However, the structure of retinal layer of the patients who had serious lens turbidity cannot be observed, which can be remedied by ophthalmic B-type ultrasound. The examination of OCT combined with ophthalmic B-type ultrasound is the most valuable one on accurate and early diagnosis of fundus diseases and the prediction of the visual acuity after surgeries.
first_indexed 2024-12-13T22:35:13Z
format Article
id doaj.art-38f8857f40dc4441805a38c26cac3e10
institution Directory Open Access Journal
issn 1672-5123
1672-5123
language English
last_indexed 2024-12-13T22:35:13Z
publishDate 2015-10-01
publisher Press of International Journal of Ophthalmology (IJO PRESS)
record_format Article
series Guoji Yanke Zazhi
spelling doaj.art-38f8857f40dc4441805a38c26cac3e102022-12-21T23:28:59ZengPress of International Journal of Ophthalmology (IJO PRESS)Guoji Yanke Zazhi1672-51231672-51232015-10-0115101817181910.3980/j.issn.1672-5123.2015.10.41Evaluation of optical coherence tomography combined with ophthalmic B-type ultrasound in fundus examination before cataract surgeriesDan Liu0Yu-Lin Tao1Li-Ming Tao2Graduate Faculty of Anhui Medical University, Hefei 230022, Anhui Province, ChinaGraduate Faculty of Anhui Medical University, Hefei 230022, Anhui Province, ChinaDepartment of Ophthalmology, the Second Hospital of Anhui Medical University, Hefei 230601, Anhui Province, ChinaAIM:To investigate the clinical value of optical coherence tomography(OCT)combined with ophthalmic B-type ultrasound in fundus examination before cataract surgeries.<p>METHODS:Conventional ophthalmoscope, ophthalmic B-type ultrasound and OCT were used to exam the fundus of 176 cataract patients(278 eyes). The positive rate of fundus diseases by the three methods was calculated, and then McNemar test was used to analyze the data in pairs and the values of the three methods on diagnosis of fundus diseases were investigated.<p>RESULTS:Thirty-two eyes were diagnosed with fundus diseases by conventional ophthalmoscope with positive rate of 11.5%, 18 eyes(6.5%)by ophthalmic B-type ultrasound, 6 eyes(2.2%)of those 18 eyes were serious lens turbidity. Fifty-one eyes(18.3%)were diagnosed with fundus diseases by OCT and 57 eyes(20.5%)by OCT combined with ophthalmic B-type ultrasound. The positive rate of fundus disease detected by OCT had significant difference at the level of α=0.05 compared with those by ophthalmic B-type ultrasound, conventional ophthalmoscope and OCT combined with ophthalmic B-type ultrasound. <p>CONCLUSION:OCT is more valuable and more sensitive on detecting macular diseases than the other two. However, the structure of retinal layer of the patients who had serious lens turbidity cannot be observed, which can be remedied by ophthalmic B-type ultrasound. The examination of OCT combined with ophthalmic B-type ultrasound is the most valuable one on accurate and early diagnosis of fundus diseases and the prediction of the visual acuity after surgeries.http://ies.ijo.cn/cn_publish/2015/10/201510041.pdfcataractoptical coherence tomographyophthalmic B-type ultrasoundconventional ophthalmoscopepreoperative examination
spellingShingle Dan Liu
Yu-Lin Tao
Li-Ming Tao
Evaluation of optical coherence tomography combined with ophthalmic B-type ultrasound in fundus examination before cataract surgeries
Guoji Yanke Zazhi
cataract
optical coherence tomography
ophthalmic B-type ultrasound
conventional ophthalmoscope
preoperative examination
title Evaluation of optical coherence tomography combined with ophthalmic B-type ultrasound in fundus examination before cataract surgeries
title_full Evaluation of optical coherence tomography combined with ophthalmic B-type ultrasound in fundus examination before cataract surgeries
title_fullStr Evaluation of optical coherence tomography combined with ophthalmic B-type ultrasound in fundus examination before cataract surgeries
title_full_unstemmed Evaluation of optical coherence tomography combined with ophthalmic B-type ultrasound in fundus examination before cataract surgeries
title_short Evaluation of optical coherence tomography combined with ophthalmic B-type ultrasound in fundus examination before cataract surgeries
title_sort evaluation of optical coherence tomography combined with ophthalmic b type ultrasound in fundus examination before cataract surgeries
topic cataract
optical coherence tomography
ophthalmic B-type ultrasound
conventional ophthalmoscope
preoperative examination
url http://ies.ijo.cn/cn_publish/2015/10/201510041.pdf
work_keys_str_mv AT danliu evaluationofopticalcoherencetomographycombinedwithophthalmicbtypeultrasoundinfundusexaminationbeforecataractsurgeries
AT yulintao evaluationofopticalcoherencetomographycombinedwithophthalmicbtypeultrasoundinfundusexaminationbeforecataractsurgeries
AT limingtao evaluationofopticalcoherencetomographycombinedwithophthalmicbtypeultrasoundinfundusexaminationbeforecataractsurgeries