Energy indicators of the micro-hydro power plant adjusted to outlet water flows from pump units

The article presents the prospects and main directions of the development of the use of hydropower sources, the parameters of the micro-hydro power plant, which works efficiently in variable and low-pressure water flows from the pumping units, and the results of the experimental studies of the micro...

Full description

Bibliographic Details
Main Authors: Uzakov G.N., Kuziev Z.E., Safarov A.B.
Format: Article
Language:English
Published: EDP Sciences 2024-01-01
Series:E3S Web of Conferences
Online Access:https://www.e3s-conferences.org/articles/e3sconf/pdf/2024/40/e3sconf_esdca2024_04010.pdf
_version_ 1797213105775706112
author Uzakov G.N.
Kuziev Z.E.
Safarov A.B.
author_facet Uzakov G.N.
Kuziev Z.E.
Safarov A.B.
author_sort Uzakov G.N.
collection DOAJ
description The article presents the prospects and main directions of the development of the use of hydropower sources, the parameters of the micro-hydro power plant, which works efficiently in variable and low-pressure water flows from the pumping units, and the results of the experimental studies of the micro-hydro power plant are presented. The developed vertical-axis micro-hydro power plant consists of a propeller-type hydro turbine with a diameter of 0.5 m, a bushing with a diameter of 0.2 m, and 6 blades with an optimal installation angle θopt=202.50°. It was determined that the maximum power of the micro-HPP is 3 kW and efficiency of the micro-HPP is equal to 0.88. Experimental work was carried out on the device, based on processing the results of the experiment, an empirical equation was obtained that determines the change in water flow consumption and turbine rotation speed of the mechanical power of the hydro turbine, and the significance of the regression equations was evaluated using Fisher‘s F-criterion. The significance level is 0.05 and at the number of degrees of freedom γ1 =63, γ2 =59 the calculated value of Fisher‘s F-criterion (Fcal= 1.03) is smaller than the value in the table (Ftab= 1,53), so the constructed regression equation is significant. The relative error of the calculation is ± 6 %. The proposed micro-HPP has the possibility of uninterrupted supply of electricity to electricity consumers in remote areas that are not connected to the centralized electricity supply system.
first_indexed 2024-04-24T10:53:00Z
format Article
id doaj.art-3948317839b047b3bd51e005205464b9
institution Directory Open Access Journal
issn 2267-1242
language English
last_indexed 2024-04-24T10:53:00Z
publishDate 2024-01-01
publisher EDP Sciences
record_format Article
series E3S Web of Conferences
spelling doaj.art-3948317839b047b3bd51e005205464b92024-04-12T07:41:19ZengEDP SciencesE3S Web of Conferences2267-12422024-01-015100401010.1051/e3sconf/202451004010e3sconf_esdca2024_04010Energy indicators of the micro-hydro power plant adjusted to outlet water flows from pump unitsUzakov G.N.0Kuziev Z.E.1Safarov A.B.2Karshi Engineering Economics InstituteBukhara Engineering Technological InstituteKarshi Engineering Economics InstituteThe article presents the prospects and main directions of the development of the use of hydropower sources, the parameters of the micro-hydro power plant, which works efficiently in variable and low-pressure water flows from the pumping units, and the results of the experimental studies of the micro-hydro power plant are presented. The developed vertical-axis micro-hydro power plant consists of a propeller-type hydro turbine with a diameter of 0.5 m, a bushing with a diameter of 0.2 m, and 6 blades with an optimal installation angle θopt=202.50°. It was determined that the maximum power of the micro-HPP is 3 kW and efficiency of the micro-HPP is equal to 0.88. Experimental work was carried out on the device, based on processing the results of the experiment, an empirical equation was obtained that determines the change in water flow consumption and turbine rotation speed of the mechanical power of the hydro turbine, and the significance of the regression equations was evaluated using Fisher‘s F-criterion. The significance level is 0.05 and at the number of degrees of freedom γ1 =63, γ2 =59 the calculated value of Fisher‘s F-criterion (Fcal= 1.03) is smaller than the value in the table (Ftab= 1,53), so the constructed regression equation is significant. The relative error of the calculation is ± 6 %. The proposed micro-HPP has the possibility of uninterrupted supply of electricity to electricity consumers in remote areas that are not connected to the centralized electricity supply system.https://www.e3s-conferences.org/articles/e3sconf/pdf/2024/40/e3sconf_esdca2024_04010.pdf
spellingShingle Uzakov G.N.
Kuziev Z.E.
Safarov A.B.
Energy indicators of the micro-hydro power plant adjusted to outlet water flows from pump units
E3S Web of Conferences
title Energy indicators of the micro-hydro power plant adjusted to outlet water flows from pump units
title_full Energy indicators of the micro-hydro power plant adjusted to outlet water flows from pump units
title_fullStr Energy indicators of the micro-hydro power plant adjusted to outlet water flows from pump units
title_full_unstemmed Energy indicators of the micro-hydro power plant adjusted to outlet water flows from pump units
title_short Energy indicators of the micro-hydro power plant adjusted to outlet water flows from pump units
title_sort energy indicators of the micro hydro power plant adjusted to outlet water flows from pump units
url https://www.e3s-conferences.org/articles/e3sconf/pdf/2024/40/e3sconf_esdca2024_04010.pdf
work_keys_str_mv AT uzakovgn energyindicatorsofthemicrohydropowerplantadjustedtooutletwaterflowsfrompumpunits
AT kuzievze energyindicatorsofthemicrohydropowerplantadjustedtooutletwaterflowsfrompumpunits
AT safarovab energyindicatorsofthemicrohydropowerplantadjustedtooutletwaterflowsfrompumpunits