Efficiency and reliability of sewage purification in long-term exploitation of the municipal wastewater treatment plant with activated sludge and hydroponic system

The aim of the work was to analyze the effi ciency and reliability of pollutants removal (total suspended solids – TSS, BOD5, COD) in a collective wastewater treatment plant with activated sludge and hydroponic lagoon during its long term operation. The tested object was designed to treat wastewater...

Full description

Bibliographic Details
Main Authors: Karolina Jóźwiakowska, Michał Marzec
Format: Article
Language:English
Published: Polish Academy of Sciences 2020-09-01
Series:Archives of Environmental Protection
Subjects:
Online Access:https://journals.pan.pl/Content/117971/Archives%20vol%2046%20no%203_30_41.pdf
_version_ 1797394332517400576
author Karolina Jóźwiakowska
Michał Marzec
author_facet Karolina Jóźwiakowska
Michał Marzec
author_sort Karolina Jóźwiakowska
collection DOAJ
description The aim of the work was to analyze the effi ciency and reliability of pollutants removal (total suspended solids – TSS, BOD5, COD) in a collective wastewater treatment plant with activated sludge and hydroponic lagoon during its long term operation. The tested object was designed to treat wastewater in flowing through the sewerage system and wastewater delivered by the septic truck. The projected capacity of the treatment plant was 1200 m3∙d-1. The technological system for wastewater treatment consisted of a mechanical part, a flowing biological reactor working according to the BARDENPHO process, a secondary settling tank and a hydroponic lagoon. The efficiency and reliability of pollutants removal in the analyzed treatment plant were assessed on the basis of the data concerning influent and effluent wastewater collected during the years 2011–2018. On the basis of the measurements results, there were determined characteristic values of the selected pollution indicators in wastewater and the average efficiency of pollutants removal. The technological reliability of the wastewater treatment plant was assessed for the basic pollution parameters (BOD5, COD, TSS) in accordance with the elements of the Weibull’s reliability theory, with regard to normative values of the indicators specified in the Regulation of the Minister of Environment. The analysis was carried out using the Statistica 13.1 software. It was proved that in the wastewater treatment plant with an activated sludge and hydroponic lagoon the level of organic pollutants removal expressed by BOD5 was on average 99.5%, COD – 98.1% and TSS – 99.4%. The technological reliability of the system was 100% in terms of the removal of pollutants from the basic group, which means that during the long term operation (8 years) it provided failure-free operation and guaranteed the fulfillment of the requirements that can be found in the Polish law regulations concerning the analyzed pollutants.
first_indexed 2024-03-09T00:18:08Z
format Article
id doaj.art-394c7a777b794c3a8b83e8f532a8e651
institution Directory Open Access Journal
issn 2083-4772
2083-4810
language English
last_indexed 2024-03-09T00:18:08Z
publishDate 2020-09-01
publisher Polish Academy of Sciences
record_format Article
series Archives of Environmental Protection
spelling doaj.art-394c7a777b794c3a8b83e8f532a8e6512023-12-12T06:43:38ZengPolish Academy of SciencesArchives of Environmental Protection2083-47722083-48102020-09-01vol. 46No 33041https://doi.org/10.24425/aep.2020.134533Efficiency and reliability of sewage purification in long-term exploitation of the municipal wastewater treatment plant with activated sludge and hydroponic systemKarolina Jóźwiakowska0Michał Marzec1Student, Faculty of Civil and Environmental Engineering, Warsaw University of Life Sciences, PolandDepartment of Environmental Engineering and Geodesy, University of Life Sciences in Lublin, PolandThe aim of the work was to analyze the effi ciency and reliability of pollutants removal (total suspended solids – TSS, BOD5, COD) in a collective wastewater treatment plant with activated sludge and hydroponic lagoon during its long term operation. The tested object was designed to treat wastewater in flowing through the sewerage system and wastewater delivered by the septic truck. The projected capacity of the treatment plant was 1200 m3∙d-1. The technological system for wastewater treatment consisted of a mechanical part, a flowing biological reactor working according to the BARDENPHO process, a secondary settling tank and a hydroponic lagoon. The efficiency and reliability of pollutants removal in the analyzed treatment plant were assessed on the basis of the data concerning influent and effluent wastewater collected during the years 2011–2018. On the basis of the measurements results, there were determined characteristic values of the selected pollution indicators in wastewater and the average efficiency of pollutants removal. The technological reliability of the wastewater treatment plant was assessed for the basic pollution parameters (BOD5, COD, TSS) in accordance with the elements of the Weibull’s reliability theory, with regard to normative values of the indicators specified in the Regulation of the Minister of Environment. The analysis was carried out using the Statistica 13.1 software. It was proved that in the wastewater treatment plant with an activated sludge and hydroponic lagoon the level of organic pollutants removal expressed by BOD5 was on average 99.5%, COD – 98.1% and TSS – 99.4%. The technological reliability of the system was 100% in terms of the removal of pollutants from the basic group, which means that during the long term operation (8 years) it provided failure-free operation and guaranteed the fulfillment of the requirements that can be found in the Polish law regulations concerning the analyzed pollutants.https://journals.pan.pl/Content/117971/Archives%20vol%2046%20no%203_30_41.pdfwastewater treatmentactivated sludgehydroponic systemefficiency and reliability of operationweibull’s reliability theory
spellingShingle Karolina Jóźwiakowska
Michał Marzec
Efficiency and reliability of sewage purification in long-term exploitation of the municipal wastewater treatment plant with activated sludge and hydroponic system
Archives of Environmental Protection
wastewater treatment
activated sludge
hydroponic system
efficiency and reliability of operation
weibull’s reliability theory
title Efficiency and reliability of sewage purification in long-term exploitation of the municipal wastewater treatment plant with activated sludge and hydroponic system
title_full Efficiency and reliability of sewage purification in long-term exploitation of the municipal wastewater treatment plant with activated sludge and hydroponic system
title_fullStr Efficiency and reliability of sewage purification in long-term exploitation of the municipal wastewater treatment plant with activated sludge and hydroponic system
title_full_unstemmed Efficiency and reliability of sewage purification in long-term exploitation of the municipal wastewater treatment plant with activated sludge and hydroponic system
title_short Efficiency and reliability of sewage purification in long-term exploitation of the municipal wastewater treatment plant with activated sludge and hydroponic system
title_sort efficiency and reliability of sewage purification in long term exploitation of the municipal wastewater treatment plant with activated sludge and hydroponic system
topic wastewater treatment
activated sludge
hydroponic system
efficiency and reliability of operation
weibull’s reliability theory
url https://journals.pan.pl/Content/117971/Archives%20vol%2046%20no%203_30_41.pdf
work_keys_str_mv AT karolinajozwiakowska efficiencyandreliabilityofsewagepurificationinlongtermexploitationofthemunicipalwastewatertreatmentplantwithactivatedsludgeandhydroponicsystem
AT michałmarzec efficiencyandreliabilityofsewagepurificationinlongtermexploitationofthemunicipalwastewatertreatmentplantwithactivatedsludgeandhydroponicsystem