COAXIAL DISK SHUNT FOR MEASURING IN THE HEAVY-CURRENT CHAIN OF HIGH-VOLTAGE GENERATOR OF STORM DISCHARGES OF IMPULSES OF CURRENT OF ARTIFICIAL LIGHTNING WITH THE INTEGRAL OF ACTION TO 15•106 J/OHM

Purpose. Description of construction and basic technical descriptions developed and created in Research & Design Institute «Molniya» National Technical University «Kharkiv Polytechnic Institute» high-voltage heavy-current coaxial disk shunt of type of SC-300M2, allowing reliably to measure the p...

Full description

Bibliographic Details
Main Authors: M. I. Baranov, V. V. Kniaziev, S. V. Rudakov
Format: Article
Language:English
Published: National Technical University "Kharkiv Polytechnic Institute" 2017-10-01
Series:Electrical engineering & Electromechanics
Subjects:
Online Access:http://eie.khpi.edu.ua/article/view/2074-272X.2017.5.07/107215
_version_ 1828959068817981440
author M. I. Baranov
V. V. Kniaziev
S. V. Rudakov
author_facet M. I. Baranov
V. V. Kniaziev
S. V. Rudakov
author_sort M. I. Baranov
collection DOAJ
description Purpose. Description of construction and basic technical descriptions developed and created in Research & Design Institute «Molniya» National Technical University «Kharkiv Polytechnic Institute» high-voltage heavy-current coaxial disk shunt of type of SC-300M2, allowing reliably to measure the peak-temporal parameters (PTP) of impulses of current of artificial lightning in wide peak and temporal ranges with the integral of their action to 15·106 J/Ohm. Methodology. Electrophysics bases of high-voltage impulsive technique, scientific and technical bases of development and creation of high-voltage heavy-current impulsive electrical equipment, including the powerful generators of current of lightning (GCL), and also measuring methods in bit chains powerful high-voltage GCL AVP large impulsive currents of micro- and millisecond temporal ranges. Results. Offered and described new construction of measuring high-voltage heavy-current shunt, containing a measuring round disk from stainless steel easily soiled a 12Х18Н10Т thickness 2 mm and external diameter 80 mm. Experimental a way impulsive active resistance of RS≈0,08 mOhm of the indicated measuring disk and on his basis a calculation coefficient transformation is found of SS of coaxial disk shunt of type of SC-300M2, numeral equal in the concerted mode of operations of his coaxial cable line (CCL) SS≈2/RS≈25·103 A/V. It is rotined that it is expedient to use this value SS for measuring in the heavy-current bit chain of GCL ATP impulsive A- and repeated impulsive D- component of current of artificial lightning, and also ATP of aperiodic impulse of current of artificial lightning of temporal form 10 μc/350 μc. It is set that taking into account application in the end CCL of shunt of a co-ordinate divizor of voltage with two output coaxial sockets 1:1 (for SSA≈25·103 A/V) and 1:2 (SSC≈12,5·103 A/V) at measuring of ATP intermediate B-, protracted C- and shortened protracted C*- component of current of artificial lightning in GCL it is expedient to utillize a numeral value SS for the examined shunt, equal 12,5·103 A/V. Practical approbation and verification of capacity of the improved measuring coaxial disk shunt of type of SC-300M2 is executed in the high-voltage heavy-current bit chain of powerful GCL, forming on the actively-inductive loading of A- and C*- the components of current of artificial lightning with rationed ATP. Originality. Developed and created new high-voltage heavy-current measuring shunt of type of SC-300M2, allowing reliably to register rationed ATP of attenuation sinewave and aperiodic impulses of current of artificial lightning in the bit chains of powerful GCL with amplitude to ±220 кА and integral them action to 13,5·106 J/Ohm. On the measuring coaxial disk shunt of type of SC-300M2 from government metrology service of Ukraine the certificate of accordance of the set form is got. Practical value. Application of the created shunt of type of SC-300M2 in composition the high-voltage heavy-current bit chains of powerful GCL will allow in a certain measure to improve the metrology providing of tests of aviation and space-rocket technique, and also objects of electroenergy on stability to lightning.
first_indexed 2024-12-14T09:00:45Z
format Article
id doaj.art-39facec0b2a24949b6e669fc43647a65
institution Directory Open Access Journal
issn 2074-272X
2309-3404
language English
last_indexed 2024-12-14T09:00:45Z
publishDate 2017-10-01
publisher National Technical University "Kharkiv Polytechnic Institute"
record_format Article
series Electrical engineering & Electromechanics
spelling doaj.art-39facec0b2a24949b6e669fc43647a652022-12-21T23:08:49ZengNational Technical University "Kharkiv Polytechnic Institute"Electrical engineering & Electromechanics2074-272X2309-34042017-10-015455010.20998/2074-272X.2017.5.07COAXIAL DISK SHUNT FOR MEASURING IN THE HEAVY-CURRENT CHAIN OF HIGH-VOLTAGE GENERATOR OF STORM DISCHARGES OF IMPULSES OF CURRENT OF ARTIFICIAL LIGHTNING WITH THE INTEGRAL OF ACTION TO 15•106 J/OHMM. I. Baranov0V. V. Kniaziev1S. V. Rudakov2National Technical University «Kharkiv Polytechnic Institute»National Technical University «Kharkiv Polytechnic Institute»National University of Civil Protection of UkrainePurpose. Description of construction and basic technical descriptions developed and created in Research & Design Institute «Molniya» National Technical University «Kharkiv Polytechnic Institute» high-voltage heavy-current coaxial disk shunt of type of SC-300M2, allowing reliably to measure the peak-temporal parameters (PTP) of impulses of current of artificial lightning in wide peak and temporal ranges with the integral of their action to 15·106 J/Ohm. Methodology. Electrophysics bases of high-voltage impulsive technique, scientific and technical bases of development and creation of high-voltage heavy-current impulsive electrical equipment, including the powerful generators of current of lightning (GCL), and also measuring methods in bit chains powerful high-voltage GCL AVP large impulsive currents of micro- and millisecond temporal ranges. Results. Offered and described new construction of measuring high-voltage heavy-current shunt, containing a measuring round disk from stainless steel easily soiled a 12Х18Н10Т thickness 2 mm and external diameter 80 mm. Experimental a way impulsive active resistance of RS≈0,08 mOhm of the indicated measuring disk and on his basis a calculation coefficient transformation is found of SS of coaxial disk shunt of type of SC-300M2, numeral equal in the concerted mode of operations of his coaxial cable line (CCL) SS≈2/RS≈25·103 A/V. It is rotined that it is expedient to use this value SS for measuring in the heavy-current bit chain of GCL ATP impulsive A- and repeated impulsive D- component of current of artificial lightning, and also ATP of aperiodic impulse of current of artificial lightning of temporal form 10 μc/350 μc. It is set that taking into account application in the end CCL of shunt of a co-ordinate divizor of voltage with two output coaxial sockets 1:1 (for SSA≈25·103 A/V) and 1:2 (SSC≈12,5·103 A/V) at measuring of ATP intermediate B-, protracted C- and shortened protracted C*- component of current of artificial lightning in GCL it is expedient to utillize a numeral value SS for the examined shunt, equal 12,5·103 A/V. Practical approbation and verification of capacity of the improved measuring coaxial disk shunt of type of SC-300M2 is executed in the high-voltage heavy-current bit chain of powerful GCL, forming on the actively-inductive loading of A- and C*- the components of current of artificial lightning with rationed ATP. Originality. Developed and created new high-voltage heavy-current measuring shunt of type of SC-300M2, allowing reliably to register rationed ATP of attenuation sinewave and aperiodic impulses of current of artificial lightning in the bit chains of powerful GCL with amplitude to ±220 кА and integral them action to 13,5·106 J/Ohm. On the measuring coaxial disk shunt of type of SC-300M2 from government metrology service of Ukraine the certificate of accordance of the set form is got. Practical value. Application of the created shunt of type of SC-300M2 in composition the high-voltage heavy-current bit chains of powerful GCL will allow in a certain measure to improve the metrology providing of tests of aviation and space-rocket technique, and also objects of electroenergy on stability to lightning.http://eie.khpi.edu.ua/article/view/2074-272X.2017.5.07/107215powerful high-voltage generator of current of lightningmeasuring coaxial disk shuntmeasuring disk of shunt from stainless steel
spellingShingle M. I. Baranov
V. V. Kniaziev
S. V. Rudakov
COAXIAL DISK SHUNT FOR MEASURING IN THE HEAVY-CURRENT CHAIN OF HIGH-VOLTAGE GENERATOR OF STORM DISCHARGES OF IMPULSES OF CURRENT OF ARTIFICIAL LIGHTNING WITH THE INTEGRAL OF ACTION TO 15•106 J/OHM
Electrical engineering & Electromechanics
powerful high-voltage generator of current of lightning
measuring coaxial disk shunt
measuring disk of shunt from stainless steel
title COAXIAL DISK SHUNT FOR MEASURING IN THE HEAVY-CURRENT CHAIN OF HIGH-VOLTAGE GENERATOR OF STORM DISCHARGES OF IMPULSES OF CURRENT OF ARTIFICIAL LIGHTNING WITH THE INTEGRAL OF ACTION TO 15•106 J/OHM
title_full COAXIAL DISK SHUNT FOR MEASURING IN THE HEAVY-CURRENT CHAIN OF HIGH-VOLTAGE GENERATOR OF STORM DISCHARGES OF IMPULSES OF CURRENT OF ARTIFICIAL LIGHTNING WITH THE INTEGRAL OF ACTION TO 15•106 J/OHM
title_fullStr COAXIAL DISK SHUNT FOR MEASURING IN THE HEAVY-CURRENT CHAIN OF HIGH-VOLTAGE GENERATOR OF STORM DISCHARGES OF IMPULSES OF CURRENT OF ARTIFICIAL LIGHTNING WITH THE INTEGRAL OF ACTION TO 15•106 J/OHM
title_full_unstemmed COAXIAL DISK SHUNT FOR MEASURING IN THE HEAVY-CURRENT CHAIN OF HIGH-VOLTAGE GENERATOR OF STORM DISCHARGES OF IMPULSES OF CURRENT OF ARTIFICIAL LIGHTNING WITH THE INTEGRAL OF ACTION TO 15•106 J/OHM
title_short COAXIAL DISK SHUNT FOR MEASURING IN THE HEAVY-CURRENT CHAIN OF HIGH-VOLTAGE GENERATOR OF STORM DISCHARGES OF IMPULSES OF CURRENT OF ARTIFICIAL LIGHTNING WITH THE INTEGRAL OF ACTION TO 15•106 J/OHM
title_sort coaxial disk shunt for measuring in the heavy current chain of high voltage generator of storm discharges of impulses of current of artificial lightning with the integral of action to 15•106 j ohm
topic powerful high-voltage generator of current of lightning
measuring coaxial disk shunt
measuring disk of shunt from stainless steel
url http://eie.khpi.edu.ua/article/view/2074-272X.2017.5.07/107215
work_keys_str_mv AT mibaranov coaxialdiskshuntformeasuringintheheavycurrentchainofhighvoltagegeneratorofstormdischargesofimpulsesofcurrentofartificiallightningwiththeintegralofactionto15106johm
AT vvkniaziev coaxialdiskshuntformeasuringintheheavycurrentchainofhighvoltagegeneratorofstormdischargesofimpulsesofcurrentofartificiallightningwiththeintegralofactionto15106johm
AT svrudakov coaxialdiskshuntformeasuringintheheavycurrentchainofhighvoltagegeneratorofstormdischargesofimpulsesofcurrentofartificiallightningwiththeintegralofactionto15106johm