Defect identification and location method of cable cross-bonded box based on head-end circulation

It is difficult to identify and locate the defects quickly when the long cable line cross-bonded box has defects such as grounding,water inflow and three-phase sequence error. Aiming at three types of typical defects of cross-bonded box,a cross-bonded model of long cable lines is established to anal...

Full description

Bibliographic Details
Main Authors: FANG Chunhua, GUO Kaige, FANG Wen, PU Ziheng, HU Dongsan, TAO Yuning
Format: Article
Language:zho
Published: Editorial Department of Electric Power Engineering Technology 2022-05-01
Series:电力工程技术
Subjects:
Online Access:https://www.epet-info.com/dlgcjs/article/abstract/210331353?st=article_issue
_version_ 1811296066396487680
author FANG Chunhua
GUO Kaige
FANG Wen
PU Ziheng
HU Dongsan
TAO Yuning
author_facet FANG Chunhua
GUO Kaige
FANG Wen
PU Ziheng
HU Dongsan
TAO Yuning
author_sort FANG Chunhua
collection DOAJ
description It is difficult to identify and locate the defects quickly when the long cable line cross-bonded box has defects such as grounding,water inflow and three-phase sequence error. Aiming at three types of typical defects of cross-bonded box,a cross-bonded model of long cable lines is established to analyze the amplitude and phase change rule of circulation under the defects. Then,the curve fitting of the ratio of circulation at both ends and the scatter data of defect box number are carried out to obtain the defect location formulas. Finally,it is verified by an example. The results show that the circulation amplitude of the defective phase increases and the non-defective phase is normal when the ground is grounded inside the box. When the phase sequence is wrong,the amplitude of two-phase circulation increases obviously,and the amplitude of the other phase circulation is smaller. When the tank is filled with water,the circulation amplitude of each phase increases and is basically equal. The fitting degree of the positioning formula is about 0.96,and the range of defect box number can be determined through the example verification. The proposed method is not affected by the change of wire core current and ground resistance,and can provide reference for the defect identification and location of long cable line cross-bonded box.
first_indexed 2024-04-13T05:42:50Z
format Article
id doaj.art-3a0f01cdba664ef48561ea14c80ca01c
institution Directory Open Access Journal
issn 2096-3203
language zho
last_indexed 2024-04-13T05:42:50Z
publishDate 2022-05-01
publisher Editorial Department of Electric Power Engineering Technology
record_format Article
series 电力工程技术
spelling doaj.art-3a0f01cdba664ef48561ea14c80ca01c2022-12-22T03:00:02ZzhoEditorial Department of Electric Power Engineering Technology电力工程技术2096-32032022-05-01413647110.12158/j.2096-3203.2022.03.008Defect identification and location method of cable cross-bonded box based on head-end circulationFANG Chunhua0GUO Kaige1FANG Wen2PU Ziheng3HU Dongsan4TAO Yuning5School of Electrical and New Energy, China Three Gorges University, Yichang 443002, ChinaSchool of Electrical and New Energy, China Three Gorges University, Yichang 443002, ChinaSchool of Electrical and New Energy, China Three Gorges University, Yichang 443002, ChinaSchool of Electrical and New Energy, China Three Gorges University, Yichang 443002, ChinaSchool of Electrical and New Energy, China Three Gorges University, Yichang 443002, ChinaSchool of Electrical and New Energy, China Three Gorges University, Yichang 443002, ChinaIt is difficult to identify and locate the defects quickly when the long cable line cross-bonded box has defects such as grounding,water inflow and three-phase sequence error. Aiming at three types of typical defects of cross-bonded box,a cross-bonded model of long cable lines is established to analyze the amplitude and phase change rule of circulation under the defects. Then,the curve fitting of the ratio of circulation at both ends and the scatter data of defect box number are carried out to obtain the defect location formulas. Finally,it is verified by an example. The results show that the circulation amplitude of the defective phase increases and the non-defective phase is normal when the ground is grounded inside the box. When the phase sequence is wrong,the amplitude of two-phase circulation increases obviously,and the amplitude of the other phase circulation is smaller. When the tank is filled with water,the circulation amplitude of each phase increases and is basically equal. The fitting degree of the positioning formula is about 0.96,and the range of defect box number can be determined through the example verification. The proposed method is not affected by the change of wire core current and ground resistance,and can provide reference for the defect identification and location of long cable line cross-bonded box.https://www.epet-info.com/dlgcjs/article/abstract/210331353?st=article_issuecable linecross-bonded boxsheath circulationthe circulation ratiodefect identificationdefect location
spellingShingle FANG Chunhua
GUO Kaige
FANG Wen
PU Ziheng
HU Dongsan
TAO Yuning
Defect identification and location method of cable cross-bonded box based on head-end circulation
电力工程技术
cable line
cross-bonded box
sheath circulation
the circulation ratio
defect identification
defect location
title Defect identification and location method of cable cross-bonded box based on head-end circulation
title_full Defect identification and location method of cable cross-bonded box based on head-end circulation
title_fullStr Defect identification and location method of cable cross-bonded box based on head-end circulation
title_full_unstemmed Defect identification and location method of cable cross-bonded box based on head-end circulation
title_short Defect identification and location method of cable cross-bonded box based on head-end circulation
title_sort defect identification and location method of cable cross bonded box based on head end circulation
topic cable line
cross-bonded box
sheath circulation
the circulation ratio
defect identification
defect location
url https://www.epet-info.com/dlgcjs/article/abstract/210331353?st=article_issue
work_keys_str_mv AT fangchunhua defectidentificationandlocationmethodofcablecrossbondedboxbasedonheadendcirculation
AT guokaige defectidentificationandlocationmethodofcablecrossbondedboxbasedonheadendcirculation
AT fangwen defectidentificationandlocationmethodofcablecrossbondedboxbasedonheadendcirculation
AT puziheng defectidentificationandlocationmethodofcablecrossbondedboxbasedonheadendcirculation
AT hudongsan defectidentificationandlocationmethodofcablecrossbondedboxbasedonheadendcirculation
AT taoyuning defectidentificationandlocationmethodofcablecrossbondedboxbasedonheadendcirculation