Failure Analysis of Laminated Composite Plate Under Hygro-Thermo Mechanical Load and Optimisation
Failure analysis of laminated composite plates for different mechanical, thermo mechanical and hygro-thermo mechanical loads for different ply thicknesses, stacking sequences, fiber orientation angles and composite material systems is presented in the paper. A comparative study of different failure...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
University of Zielona Góra
2019-08-01
|
Series: | International Journal of Applied Mechanics and Engineering |
Subjects: | |
Online Access: | https://www.ijame-poland.com/Failure-Analysis-of-Laminated-Composite-Plate-Under-Hygro-Thermo-Mechanical-Load,166902,0,2.html |
_version_ | 1797750477545275392 |
---|---|
author | A. Choudhury S.C. Mondal S. Sarkar |
author_facet | A. Choudhury S.C. Mondal S. Sarkar |
author_sort | A. Choudhury |
collection | DOAJ |
description | Failure analysis of laminated composite plates for different mechanical, thermo mechanical and hygro-thermo mechanical loads for different ply thicknesses, stacking sequences, fiber orientation angles and composite material systems is presented in the paper. A comparative study of different failure theories is also presented in the paper. The effect of fiber orientation angles on the first ply failure load is also studied. A hybrid composite laminate is developed based on the first ply failure load which minimizes weight and cost. The last ply failure load based on fully discounted method is calculated for different stacking sequences. An optimum composite material system and laminate layup is studied for a targeted strength ratio which minimizes weight. |
first_indexed | 2024-03-12T16:33:18Z |
format | Article |
id | doaj.art-3a7240e95e764a5688621413869937cb |
institution | Directory Open Access Journal |
issn | 1734-4492 2353-9003 |
language | English |
last_indexed | 2024-03-12T16:33:18Z |
publishDate | 2019-08-01 |
publisher | University of Zielona Góra |
record_format | Article |
series | International Journal of Applied Mechanics and Engineering |
spelling | doaj.art-3a7240e95e764a5688621413869937cb2023-08-08T15:01:27ZengUniversity of Zielona GóraInternational Journal of Applied Mechanics and Engineering1734-44922353-90032019-08-0124350952610.2478/ijame-2019-0032166902Failure Analysis of Laminated Composite Plate Under Hygro-Thermo Mechanical Load and OptimisationA. Choudhury0S.C. Mondal1S. Sarkar2Department of Mechanical Engineering, Jadavpur University, Kolkata, IndiaDepartment of Mechanical Engineering, Jadavpur University, Kolkata, IndiaDepartment of Mechanical Engineering, Jadavpur University, Kolkata, IndiaFailure analysis of laminated composite plates for different mechanical, thermo mechanical and hygro-thermo mechanical loads for different ply thicknesses, stacking sequences, fiber orientation angles and composite material systems is presented in the paper. A comparative study of different failure theories is also presented in the paper. The effect of fiber orientation angles on the first ply failure load is also studied. A hybrid composite laminate is developed based on the first ply failure load which minimizes weight and cost. The last ply failure load based on fully discounted method is calculated for different stacking sequences. An optimum composite material system and laminate layup is studied for a targeted strength ratio which minimizes weight.https://www.ijame-poland.com/Failure-Analysis-of-Laminated-Composite-Plate-Under-Hygro-Thermo-Mechanical-Load,166902,0,2.htmlfirst ply failure loadlast ply failure loadstrength ratiofiber orientation anglehybrid composite |
spellingShingle | A. Choudhury S.C. Mondal S. Sarkar Failure Analysis of Laminated Composite Plate Under Hygro-Thermo Mechanical Load and Optimisation International Journal of Applied Mechanics and Engineering first ply failure load last ply failure load strength ratio fiber orientation angle hybrid composite |
title | Failure Analysis of Laminated Composite Plate Under Hygro-Thermo Mechanical Load and Optimisation |
title_full | Failure Analysis of Laminated Composite Plate Under Hygro-Thermo Mechanical Load and Optimisation |
title_fullStr | Failure Analysis of Laminated Composite Plate Under Hygro-Thermo Mechanical Load and Optimisation |
title_full_unstemmed | Failure Analysis of Laminated Composite Plate Under Hygro-Thermo Mechanical Load and Optimisation |
title_short | Failure Analysis of Laminated Composite Plate Under Hygro-Thermo Mechanical Load and Optimisation |
title_sort | failure analysis of laminated composite plate under hygro thermo mechanical load and optimisation |
topic | first ply failure load last ply failure load strength ratio fiber orientation angle hybrid composite |
url | https://www.ijame-poland.com/Failure-Analysis-of-Laminated-Composite-Plate-Under-Hygro-Thermo-Mechanical-Load,166902,0,2.html |
work_keys_str_mv | AT achoudhury failureanalysisoflaminatedcompositeplateunderhygrothermomechanicalloadandoptimisation AT scmondal failureanalysisoflaminatedcompositeplateunderhygrothermomechanicalloadandoptimisation AT ssarkar failureanalysisoflaminatedcompositeplateunderhygrothermomechanicalloadandoptimisation |