Modelling and Evaluation of the Absorption of the 866 MHz Electromagnetic Field in Humans Exposed near to Fixed I-RFID Readers Used in Medical RTLS or to Monitor PPE

The aim of this study was to model and evaluate the Specific Energy Absorption Rate (SAR) values in humans in proximity to fixed multi-antenna I-RFID readers of passive tags under various scenarios mimicking exposure when they are incorporated in Real-Time Location Systems (RTLS), or used to monitor...

Full description

Bibliographic Details
Main Authors: Patryk Zradziński, Jolanta Karpowicz, Krzysztof Gryz, Grzegorz Owczarek, Victoria Ramos
Format: Article
Language:English
Published: MDPI AG 2021-06-01
Series:Sensors
Subjects:
Online Access:https://www.mdpi.com/1424-8220/21/12/4251
_version_ 1797529345136263168
author Patryk Zradziński
Jolanta Karpowicz
Krzysztof Gryz
Grzegorz Owczarek
Victoria Ramos
author_facet Patryk Zradziński
Jolanta Karpowicz
Krzysztof Gryz
Grzegorz Owczarek
Victoria Ramos
author_sort Patryk Zradziński
collection DOAJ
description The aim of this study was to model and evaluate the Specific Energy Absorption Rate (SAR) values in humans in proximity to fixed multi-antenna I-RFID readers of passive tags under various scenarios mimicking exposure when they are incorporated in Real-Time Location Systems (RTLS), or used to monitor Personal Protective Equipment (PPE). The sources of the electromagnetic field (EMF) in the modelled readers were rectangular microstrip antennas at a resonance frequency in free space of 866 MHz from the ultra-high frequency (UHF) RFID frequency range of 865–868 MHz. The obtained results of numerical modelling showed that the SAR values in the body 5 cm away from the UHF RFID readers need consideration with respect to exposure limits set by international guidelines to prevent adverse thermal effects of exposure to EMF: when the effective radiated power exceeds 5.5 W with respect to the general public/unrestricted environments exposure limits, and with respect to occupational/restricted environments exposure limits, when the effective radiated power exceeds 27.5 W.
first_indexed 2024-03-10T10:12:31Z
format Article
id doaj.art-3b85ff774ff94a5b991235b491ccb168
institution Directory Open Access Journal
issn 1424-8220
language English
last_indexed 2024-03-10T10:12:31Z
publishDate 2021-06-01
publisher MDPI AG
record_format Article
series Sensors
spelling doaj.art-3b85ff774ff94a5b991235b491ccb1682023-11-22T01:05:25ZengMDPI AGSensors1424-82202021-06-012112425110.3390/s21124251Modelling and Evaluation of the Absorption of the 866 MHz Electromagnetic Field in Humans Exposed near to Fixed I-RFID Readers Used in Medical RTLS or to Monitor PPEPatryk Zradziński0Jolanta Karpowicz1Krzysztof Gryz2Grzegorz Owczarek3Victoria Ramos4Laboratory of Electromagnetic Hazards, Central Institute for Labour Protection–National Research Institute (CIOP-PIB), Czerniakowska 16, 00-701 Warszawa, PolandLaboratory of Electromagnetic Hazards, Central Institute for Labour Protection–National Research Institute (CIOP-PIB), Czerniakowska 16, 00-701 Warszawa, PolandLaboratory of Electromagnetic Hazards, Central Institute for Labour Protection–National Research Institute (CIOP-PIB), Czerniakowska 16, 00-701 Warszawa, PolandEye and Face Protection Laboratory, Central Institute for Labour Protection–National Research Institute (CIOP-PIB), Czerniakowska 16, 00-701 Warszawa, PolandTelemedicine and e-Health Research Unit, Instituto de Salud Carlos III, Avda. Monforte de Lemos, 5, 28029 Madrid, SpainThe aim of this study was to model and evaluate the Specific Energy Absorption Rate (SAR) values in humans in proximity to fixed multi-antenna I-RFID readers of passive tags under various scenarios mimicking exposure when they are incorporated in Real-Time Location Systems (RTLS), or used to monitor Personal Protective Equipment (PPE). The sources of the electromagnetic field (EMF) in the modelled readers were rectangular microstrip antennas at a resonance frequency in free space of 866 MHz from the ultra-high frequency (UHF) RFID frequency range of 865–868 MHz. The obtained results of numerical modelling showed that the SAR values in the body 5 cm away from the UHF RFID readers need consideration with respect to exposure limits set by international guidelines to prevent adverse thermal effects of exposure to EMF: when the effective radiated power exceeds 5.5 W with respect to the general public/unrestricted environments exposure limits, and with respect to occupational/restricted environments exposure limits, when the effective radiated power exceeds 27.5 W.https://www.mdpi.com/1424-8220/21/12/4251biomedical engineeringenvironmental engineeringnumerical simulationsoccupational exposurepublic healthspecific energy absorption rate (SAR)
spellingShingle Patryk Zradziński
Jolanta Karpowicz
Krzysztof Gryz
Grzegorz Owczarek
Victoria Ramos
Modelling and Evaluation of the Absorption of the 866 MHz Electromagnetic Field in Humans Exposed near to Fixed I-RFID Readers Used in Medical RTLS or to Monitor PPE
Sensors
biomedical engineering
environmental engineering
numerical simulations
occupational exposure
public health
specific energy absorption rate (SAR)
title Modelling and Evaluation of the Absorption of the 866 MHz Electromagnetic Field in Humans Exposed near to Fixed I-RFID Readers Used in Medical RTLS or to Monitor PPE
title_full Modelling and Evaluation of the Absorption of the 866 MHz Electromagnetic Field in Humans Exposed near to Fixed I-RFID Readers Used in Medical RTLS or to Monitor PPE
title_fullStr Modelling and Evaluation of the Absorption of the 866 MHz Electromagnetic Field in Humans Exposed near to Fixed I-RFID Readers Used in Medical RTLS or to Monitor PPE
title_full_unstemmed Modelling and Evaluation of the Absorption of the 866 MHz Electromagnetic Field in Humans Exposed near to Fixed I-RFID Readers Used in Medical RTLS or to Monitor PPE
title_short Modelling and Evaluation of the Absorption of the 866 MHz Electromagnetic Field in Humans Exposed near to Fixed I-RFID Readers Used in Medical RTLS or to Monitor PPE
title_sort modelling and evaluation of the absorption of the 866 mhz electromagnetic field in humans exposed near to fixed i rfid readers used in medical rtls or to monitor ppe
topic biomedical engineering
environmental engineering
numerical simulations
occupational exposure
public health
specific energy absorption rate (SAR)
url https://www.mdpi.com/1424-8220/21/12/4251
work_keys_str_mv AT patrykzradzinski modellingandevaluationoftheabsorptionofthe866mhzelectromagneticfieldinhumansexposedneartofixedirfidreadersusedinmedicalrtlsortomonitorppe
AT jolantakarpowicz modellingandevaluationoftheabsorptionofthe866mhzelectromagneticfieldinhumansexposedneartofixedirfidreadersusedinmedicalrtlsortomonitorppe
AT krzysztofgryz modellingandevaluationoftheabsorptionofthe866mhzelectromagneticfieldinhumansexposedneartofixedirfidreadersusedinmedicalrtlsortomonitorppe
AT grzegorzowczarek modellingandevaluationoftheabsorptionofthe866mhzelectromagneticfieldinhumansexposedneartofixedirfidreadersusedinmedicalrtlsortomonitorppe
AT victoriaramos modellingandevaluationoftheabsorptionofthe866mhzelectromagneticfieldinhumansexposedneartofixedirfidreadersusedinmedicalrtlsortomonitorppe