Sensor-Location-Specific Joint Acquisition of Peripheral Artery Bioimpedance and Photoplethysmogram for Wearable Applications

Background: Cardiovascular diseases (CVDs), being the culprit for one-third of deaths globally, constitute a challenge for biomedical instrumentation development, especially for early disease detection. Pulsating arterial blood flow, providing access to cardiac-related parameters, involves the whole...

Full description

Bibliographic Details
Main Authors: Margus Metshein, Anar Abdullayev, Antoine Gautier, Benoit Larras, Antoine Frappe, Barry Cardiff, Paul Annus, Raul Land, Olev Märtens
Format: Article
Language:English
Published: MDPI AG 2023-08-01
Series:Sensors
Subjects:
Online Access:https://www.mdpi.com/1424-8220/23/16/7111
_version_ 1827728683638456320
author Margus Metshein
Anar Abdullayev
Antoine Gautier
Benoit Larras
Antoine Frappe
Barry Cardiff
Paul Annus
Raul Land
Olev Märtens
author_facet Margus Metshein
Anar Abdullayev
Antoine Gautier
Benoit Larras
Antoine Frappe
Barry Cardiff
Paul Annus
Raul Land
Olev Märtens
author_sort Margus Metshein
collection DOAJ
description Background: Cardiovascular diseases (CVDs), being the culprit for one-third of deaths globally, constitute a challenge for biomedical instrumentation development, especially for early disease detection. Pulsating arterial blood flow, providing access to cardiac-related parameters, involves the whole body. Unobtrusive and continuous acquisition of electrical bioimpedance (EBI) and photoplethysmography (PPG) constitute important techniques for monitoring the peripheral arteries, requiring novel approaches and clever means. Methods: In this work, five peripheral arteries were selected for EBI and PPG signal acquisition. The acquisition sites were evaluated based on the signal morphological parameters. A small-data-based deep learning model, which increases the data by dividing them into cardiac periods, was proposed to evaluate the continuity of the signals. Results: The highest sensitivity of EBI was gained for the carotid artery (0.86%), three times higher than that for the next best, the posterior tibial artery (0.27%). The excitation signal parameters affect the measured EBI, confirming the suitability of classical 100 kHz frequency (average probability of 52.35%). The continuity evaluation of the EBI signals confirmed the advantage of the carotid artery (59.4%), while the posterior tibial artery (49.26%) surpasses the radial artery (48.17%). The PPG signal, conversely, commends the location of the posterior tibial artery (97.87%). Conclusions: The peripheral arteries are highly suitable for non-invasive EBI and PPG signal acquisition. The posterior tibial artery constitutes a candidate for the joint acquisition of EBI and PPG signals in sensor-fusion-based wearable devices—an important finding of this research.
first_indexed 2024-03-10T23:35:30Z
format Article
id doaj.art-3bec0d8f2fa14e438e0309814fe2d829
institution Directory Open Access Journal
issn 1424-8220
language English
last_indexed 2024-03-10T23:35:30Z
publishDate 2023-08-01
publisher MDPI AG
record_format Article
series Sensors
spelling doaj.art-3bec0d8f2fa14e438e0309814fe2d8292023-11-19T02:56:57ZengMDPI AGSensors1424-82202023-08-012316711110.3390/s23167111Sensor-Location-Specific Joint Acquisition of Peripheral Artery Bioimpedance and Photoplethysmogram for Wearable ApplicationsMargus Metshein0Anar Abdullayev1Antoine Gautier2Benoit Larras3Antoine Frappe4Barry Cardiff5Paul Annus6Raul Land7Olev Märtens8Thomas Johann Seebeck Department of Electronics, Tallinn University of Technology, Ehitajate Tee 5, 19086 Tallinn, EstoniaThomas Johann Seebeck Department of Electronics, Tallinn University of Technology, Ehitajate Tee 5, 19086 Tallinn, EstoniaUniversity Lille, CNRS, Centrale Lille, Junia, University Polytechnique Hauts-de-France, UMR 8520-IEMN, F-59000 Lille, FranceUniversity Lille, CNRS, Centrale Lille, Junia, University Polytechnique Hauts-de-France, UMR 8520-IEMN, F-59000 Lille, FranceUniversity Lille, CNRS, Centrale Lille, Junia, University Polytechnique Hauts-de-France, UMR 8520-IEMN, F-59000 Lille, FranceSchool of Electrical and Electronic Engineering, University College Dublin, D04V1W8 Dublin, IrelandThomas Johann Seebeck Department of Electronics, Tallinn University of Technology, Ehitajate Tee 5, 19086 Tallinn, EstoniaThomas Johann Seebeck Department of Electronics, Tallinn University of Technology, Ehitajate Tee 5, 19086 Tallinn, EstoniaThomas Johann Seebeck Department of Electronics, Tallinn University of Technology, Ehitajate Tee 5, 19086 Tallinn, EstoniaBackground: Cardiovascular diseases (CVDs), being the culprit for one-third of deaths globally, constitute a challenge for biomedical instrumentation development, especially for early disease detection. Pulsating arterial blood flow, providing access to cardiac-related parameters, involves the whole body. Unobtrusive and continuous acquisition of electrical bioimpedance (EBI) and photoplethysmography (PPG) constitute important techniques for monitoring the peripheral arteries, requiring novel approaches and clever means. Methods: In this work, five peripheral arteries were selected for EBI and PPG signal acquisition. The acquisition sites were evaluated based on the signal morphological parameters. A small-data-based deep learning model, which increases the data by dividing them into cardiac periods, was proposed to evaluate the continuity of the signals. Results: The highest sensitivity of EBI was gained for the carotid artery (0.86%), three times higher than that for the next best, the posterior tibial artery (0.27%). The excitation signal parameters affect the measured EBI, confirming the suitability of classical 100 kHz frequency (average probability of 52.35%). The continuity evaluation of the EBI signals confirmed the advantage of the carotid artery (59.4%), while the posterior tibial artery (49.26%) surpasses the radial artery (48.17%). The PPG signal, conversely, commends the location of the posterior tibial artery (97.87%). Conclusions: The peripheral arteries are highly suitable for non-invasive EBI and PPG signal acquisition. The posterior tibial artery constitutes a candidate for the joint acquisition of EBI and PPG signals in sensor-fusion-based wearable devices—an important finding of this research.https://www.mdpi.com/1424-8220/23/16/7111cardiovascular systemconvolutional neural networkselectrical bioimpedancedeep learningphotoplethysmographynon-invasive measurements
spellingShingle Margus Metshein
Anar Abdullayev
Antoine Gautier
Benoit Larras
Antoine Frappe
Barry Cardiff
Paul Annus
Raul Land
Olev Märtens
Sensor-Location-Specific Joint Acquisition of Peripheral Artery Bioimpedance and Photoplethysmogram for Wearable Applications
Sensors
cardiovascular system
convolutional neural networks
electrical bioimpedance
deep learning
photoplethysmography
non-invasive measurements
title Sensor-Location-Specific Joint Acquisition of Peripheral Artery Bioimpedance and Photoplethysmogram for Wearable Applications
title_full Sensor-Location-Specific Joint Acquisition of Peripheral Artery Bioimpedance and Photoplethysmogram for Wearable Applications
title_fullStr Sensor-Location-Specific Joint Acquisition of Peripheral Artery Bioimpedance and Photoplethysmogram for Wearable Applications
title_full_unstemmed Sensor-Location-Specific Joint Acquisition of Peripheral Artery Bioimpedance and Photoplethysmogram for Wearable Applications
title_short Sensor-Location-Specific Joint Acquisition of Peripheral Artery Bioimpedance and Photoplethysmogram for Wearable Applications
title_sort sensor location specific joint acquisition of peripheral artery bioimpedance and photoplethysmogram for wearable applications
topic cardiovascular system
convolutional neural networks
electrical bioimpedance
deep learning
photoplethysmography
non-invasive measurements
url https://www.mdpi.com/1424-8220/23/16/7111
work_keys_str_mv AT margusmetshein sensorlocationspecificjointacquisitionofperipheralarterybioimpedanceandphotoplethysmogramforwearableapplications
AT anarabdullayev sensorlocationspecificjointacquisitionofperipheralarterybioimpedanceandphotoplethysmogramforwearableapplications
AT antoinegautier sensorlocationspecificjointacquisitionofperipheralarterybioimpedanceandphotoplethysmogramforwearableapplications
AT benoitlarras sensorlocationspecificjointacquisitionofperipheralarterybioimpedanceandphotoplethysmogramforwearableapplications
AT antoinefrappe sensorlocationspecificjointacquisitionofperipheralarterybioimpedanceandphotoplethysmogramforwearableapplications
AT barrycardiff sensorlocationspecificjointacquisitionofperipheralarterybioimpedanceandphotoplethysmogramforwearableapplications
AT paulannus sensorlocationspecificjointacquisitionofperipheralarterybioimpedanceandphotoplethysmogramforwearableapplications
AT raulland sensorlocationspecificjointacquisitionofperipheralarterybioimpedanceandphotoplethysmogramforwearableapplications
AT olevmartens sensorlocationspecificjointacquisitionofperipheralarterybioimpedanceandphotoplethysmogramforwearableapplications