The Effect of an Er, Cr: YSGG Laser Combined with Implantoplasty Treatment on Implant Surface Roughness and Morphologic Analysis: A Pilot In Vitro Study
Although laser irradiation and implantoplasty (IP) are both treatment options for peri-implantitis, no studies have yet combined these two treatment solutions. The aim of this study was to identify the effect of an Er, Cr: YSGG laser on the IP surface. In experiment 1, TiUnite anodized surface impla...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2022-08-01
|
Series: | Journal of Functional Biomaterials |
Subjects: | |
Online Access: | https://www.mdpi.com/2079-4983/13/3/133 |
_version_ | 1797486494641815552 |
---|---|
author | Chih-Jen Lin Ming-Hsu Tsai Yu-Ling Wu Hsuan Lung Hung-Shyong Chen Aaron Yu-Jen Wu |
author_facet | Chih-Jen Lin Ming-Hsu Tsai Yu-Ling Wu Hsuan Lung Hung-Shyong Chen Aaron Yu-Jen Wu |
author_sort | Chih-Jen Lin |
collection | DOAJ |
description | Although laser irradiation and implantoplasty (IP) are both treatment options for peri-implantitis, no studies have yet combined these two treatment solutions. The aim of this study was to identify the effect of an Er, Cr: YSGG laser on the IP surface. In experiment 1, TiUnite anodized surface implants were treated with an Er, Cr: YSGG laser at 0.5 to 2 W on the panel energy setting and 20 Hz under water irrigation. In experiment 2, all implant surfaces were treated with the IP procedure first, then irradiated with the Er, Cr: YSGG laser. All samples were analyzed by stereomicroscopy, scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), and surface topography. Stereomicroscopy and SEM revealed no obvious surface change at any energy setting once the surface was polished with the IP procedure, whereas damage was caused to the TiUnite original implant surface when the Er, Cr: YSGG laser panel energy was set at 1 W or higher. EDS showed no significant difference in element composition once the surface was polished with the IP procedure, while a compositional change was detected when the Er, Cr: YSGG laser panel energy was set to 0.5 W or higher to irradiate the original TiUnite surface. Surface roughness may be related to laser irradiation energy, but no significant changes occurred following IP. These results indicated that the Er, Cr: YSGG laser may have little effect on the post-IP surface compared with the virgin TiUnite surface. |
first_indexed | 2024-03-09T23:33:59Z |
format | Article |
id | doaj.art-3c366e81d9ca4defaa71c09db1112bf9 |
institution | Directory Open Access Journal |
issn | 2079-4983 |
language | English |
last_indexed | 2024-03-09T23:33:59Z |
publishDate | 2022-08-01 |
publisher | MDPI AG |
record_format | Article |
series | Journal of Functional Biomaterials |
spelling | doaj.art-3c366e81d9ca4defaa71c09db1112bf92023-11-23T17:03:37ZengMDPI AGJournal of Functional Biomaterials2079-49832022-08-0113313310.3390/jfb13030133The Effect of an Er, Cr: YSGG Laser Combined with Implantoplasty Treatment on Implant Surface Roughness and Morphologic Analysis: A Pilot In Vitro StudyChih-Jen Lin0Ming-Hsu Tsai1Yu-Ling Wu2Hsuan Lung3Hung-Shyong Chen4Aaron Yu-Jen Wu5Department of Dentistry, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung 833, TaiwanDepartment of Mechanical Engineering, Cheng Shiu University, Kaohsiung 833, TaiwanDepartment of Dentistry, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung 833, TaiwanDepartment of Dentistry, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung 833, TaiwanDepartment of Mechanical Engineering, Cheng Shiu University, Kaohsiung 833, TaiwanDepartment of Dentistry, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung 833, TaiwanAlthough laser irradiation and implantoplasty (IP) are both treatment options for peri-implantitis, no studies have yet combined these two treatment solutions. The aim of this study was to identify the effect of an Er, Cr: YSGG laser on the IP surface. In experiment 1, TiUnite anodized surface implants were treated with an Er, Cr: YSGG laser at 0.5 to 2 W on the panel energy setting and 20 Hz under water irrigation. In experiment 2, all implant surfaces were treated with the IP procedure first, then irradiated with the Er, Cr: YSGG laser. All samples were analyzed by stereomicroscopy, scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), and surface topography. Stereomicroscopy and SEM revealed no obvious surface change at any energy setting once the surface was polished with the IP procedure, whereas damage was caused to the TiUnite original implant surface when the Er, Cr: YSGG laser panel energy was set at 1 W or higher. EDS showed no significant difference in element composition once the surface was polished with the IP procedure, while a compositional change was detected when the Er, Cr: YSGG laser panel energy was set to 0.5 W or higher to irradiate the original TiUnite surface. Surface roughness may be related to laser irradiation energy, but no significant changes occurred following IP. These results indicated that the Er, Cr: YSGG laser may have little effect on the post-IP surface compared with the virgin TiUnite surface.https://www.mdpi.com/2079-4983/13/3/133Er, Cr: YSGG LaserimplantitisimplantoplastyTiUnite surface |
spellingShingle | Chih-Jen Lin Ming-Hsu Tsai Yu-Ling Wu Hsuan Lung Hung-Shyong Chen Aaron Yu-Jen Wu The Effect of an Er, Cr: YSGG Laser Combined with Implantoplasty Treatment on Implant Surface Roughness and Morphologic Analysis: A Pilot In Vitro Study Journal of Functional Biomaterials Er, Cr: YSGG Laser implantitis implantoplasty TiUnite surface |
title | The Effect of an Er, Cr: YSGG Laser Combined with Implantoplasty Treatment on Implant Surface Roughness and Morphologic Analysis: A Pilot In Vitro Study |
title_full | The Effect of an Er, Cr: YSGG Laser Combined with Implantoplasty Treatment on Implant Surface Roughness and Morphologic Analysis: A Pilot In Vitro Study |
title_fullStr | The Effect of an Er, Cr: YSGG Laser Combined with Implantoplasty Treatment on Implant Surface Roughness and Morphologic Analysis: A Pilot In Vitro Study |
title_full_unstemmed | The Effect of an Er, Cr: YSGG Laser Combined with Implantoplasty Treatment on Implant Surface Roughness and Morphologic Analysis: A Pilot In Vitro Study |
title_short | The Effect of an Er, Cr: YSGG Laser Combined with Implantoplasty Treatment on Implant Surface Roughness and Morphologic Analysis: A Pilot In Vitro Study |
title_sort | effect of an er cr ysgg laser combined with implantoplasty treatment on implant surface roughness and morphologic analysis a pilot in vitro study |
topic | Er, Cr: YSGG Laser implantitis implantoplasty TiUnite surface |
url | https://www.mdpi.com/2079-4983/13/3/133 |
work_keys_str_mv | AT chihjenlin theeffectofanercrysgglasercombinedwithimplantoplastytreatmentonimplantsurfaceroughnessandmorphologicanalysisapilotinvitrostudy AT minghsutsai theeffectofanercrysgglasercombinedwithimplantoplastytreatmentonimplantsurfaceroughnessandmorphologicanalysisapilotinvitrostudy AT yulingwu theeffectofanercrysgglasercombinedwithimplantoplastytreatmentonimplantsurfaceroughnessandmorphologicanalysisapilotinvitrostudy AT hsuanlung theeffectofanercrysgglasercombinedwithimplantoplastytreatmentonimplantsurfaceroughnessandmorphologicanalysisapilotinvitrostudy AT hungshyongchen theeffectofanercrysgglasercombinedwithimplantoplastytreatmentonimplantsurfaceroughnessandmorphologicanalysisapilotinvitrostudy AT aaronyujenwu theeffectofanercrysgglasercombinedwithimplantoplastytreatmentonimplantsurfaceroughnessandmorphologicanalysisapilotinvitrostudy AT chihjenlin effectofanercrysgglasercombinedwithimplantoplastytreatmentonimplantsurfaceroughnessandmorphologicanalysisapilotinvitrostudy AT minghsutsai effectofanercrysgglasercombinedwithimplantoplastytreatmentonimplantsurfaceroughnessandmorphologicanalysisapilotinvitrostudy AT yulingwu effectofanercrysgglasercombinedwithimplantoplastytreatmentonimplantsurfaceroughnessandmorphologicanalysisapilotinvitrostudy AT hsuanlung effectofanercrysgglasercombinedwithimplantoplastytreatmentonimplantsurfaceroughnessandmorphologicanalysisapilotinvitrostudy AT hungshyongchen effectofanercrysgglasercombinedwithimplantoplastytreatmentonimplantsurfaceroughnessandmorphologicanalysisapilotinvitrostudy AT aaronyujenwu effectofanercrysgglasercombinedwithimplantoplastytreatmentonimplantsurfaceroughnessandmorphologicanalysisapilotinvitrostudy |