Degradation Phenomena on “Homemade” Explanted Aortic Textile Endografts

Objective: In the 1990s, the concept of “homemade” endografts (EGs) using commercially available materials was proposed in clinical practice for endovascular abdominal aortic repair (EVAR). The aim of this study was to analyse the ageing phenomena of these EGs in light of explant analyses. Methods:...

Full description

Bibliographic Details
Main Authors: Sheng-Heng Cao, Jennifer Canonge, Julien Gaudric, Delphine Dion, Salomé Kuntz, Jérémie Jayet, Fabien Koskas, Frédéric Heim, Anne Lejay, Nabil Chakfé
Format: Article
Language:English
Published: Elsevier 2021-01-01
Series:EJVES Vascular Forum
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2666688X21000344
_version_ 1819096479380275200
author Sheng-Heng Cao
Jennifer Canonge
Julien Gaudric
Delphine Dion
Salomé Kuntz
Jérémie Jayet
Fabien Koskas
Frédéric Heim
Anne Lejay
Nabil Chakfé
author_facet Sheng-Heng Cao
Jennifer Canonge
Julien Gaudric
Delphine Dion
Salomé Kuntz
Jérémie Jayet
Fabien Koskas
Frédéric Heim
Anne Lejay
Nabil Chakfé
author_sort Sheng-Heng Cao
collection DOAJ
description Objective: In the 1990s, the concept of “homemade” endografts (EGs) using commercially available materials was proposed in clinical practice for endovascular abdominal aortic repair (EVAR). The aim of this study was to analyse the ageing phenomena of these EGs in light of explant analyses. Methods: The study focused on five explanted homemade EGs collected from 2012 to 2014. The explants were assessed in accordance with the ISO 9001/13485 certified standard protocol, which included naked eye evaluation, organic remnant cleaning, and microscopic and endoscopic examinations and analysis (magnification range from 20% to 200%). The observations report followed a classification based on 12 features assessing the fabric cover, the stitch filament, and the stents. Results: The reasons for explantation were type 1 endoleak in three cases and aneurysm sac growth in two. The implantation duration ranged from 56 to 202 months. Sixty three per cent of the fabric surface lesions (holes and tears) were related to abrasion between the fabric and the stents. Up to 33% of the knots used to connect adjacent stents were broken on one EG. Other defects including running suture rupture and stent corrosion were also observed. The overall hole cumulated surface ranged from 0.377 mm2 (56 month of implantation) up to 3.21 mm2 (78 month of implantation). Conclusion: In this study, various ageing phenomena on homemade textile EGs were identified and classified. The main damaging mechanisms were related to abrasion stress leading to tears and holes in the fabric, stitch ruptures, and detachment of stent segments responsible for serious EG deformations and further degradation.
first_indexed 2024-12-21T23:59:51Z
format Article
id doaj.art-3c990a8f1bf549cbadda42fd969bd1bb
institution Directory Open Access Journal
issn 2666-688X
language English
last_indexed 2024-12-21T23:59:51Z
publishDate 2021-01-01
publisher Elsevier
record_format Article
series EJVES Vascular Forum
spelling doaj.art-3c990a8f1bf549cbadda42fd969bd1bb2022-12-21T18:45:44ZengElsevierEJVES Vascular Forum2666-688X2021-01-015328Degradation Phenomena on “Homemade” Explanted Aortic Textile EndograftsSheng-Heng Cao0Jennifer Canonge1Julien Gaudric2Delphine Dion3Salomé Kuntz4Jérémie Jayet5Fabien Koskas6Frédéric Heim7Anne Lejay8Nabil Chakfé9Groupe Européen de Recherche sur les Prothèses Appliquées à la Chirurgie Vasculaire, Strasbourg, FranceGroupe Européen de Recherche sur les Prothèses Appliquées à la Chirurgie Vasculaire, Strasbourg, FranceGroupe Européen de Recherche sur les Prothèses Appliquées à la Chirurgie Vasculaire, Strasbourg, France; Department of Vascular Surgery La Pitié Salpétrière, Sorbonne Université, Paris, FranceGroupe Européen de Recherche sur les Prothèses Appliquées à la Chirurgie Vasculaire, Strasbourg, FranceGroupe Européen de Recherche sur les Prothèses Appliquées à la Chirurgie Vasculaire, Strasbourg, France; Department of Vascular Surgery and Kidney Transplantation, University Hospital of Strasbourg, Strasbourg, FranceGroupe Européen de Recherche sur les Prothèses Appliquées à la Chirurgie Vasculaire, Strasbourg, France; Department of Vascular Surgery La Pitié Salpétrière, Sorbonne Université, Paris, FranceDepartment of Vascular Surgery La Pitié Salpétrière, Sorbonne Université, Paris, FranceGroupe Européen de Recherche sur les Prothèses Appliquées à la Chirurgie Vasculaire, Strasbourg, France; Laboratoire de Physique et Mécanique Textile, Université de Haute-Alsace, Mulhouse, FranceGroupe Européen de Recherche sur les Prothèses Appliquées à la Chirurgie Vasculaire, Strasbourg, France; Department of Vascular Surgery and Kidney Transplantation, University Hospital of Strasbourg, Strasbourg, FranceGroupe Européen de Recherche sur les Prothèses Appliquées à la Chirurgie Vasculaire, Strasbourg, France; Department of Vascular Surgery and Kidney Transplantation, University Hospital of Strasbourg, Strasbourg, France; Corresponding author. Department of Vascular Surgery and Kidney Transplantation, Les Hôpitaux Universitaires de Strasbourg, B.P. 426, 67091, Strasbourg Cedex, France.Objective: In the 1990s, the concept of “homemade” endografts (EGs) using commercially available materials was proposed in clinical practice for endovascular abdominal aortic repair (EVAR). The aim of this study was to analyse the ageing phenomena of these EGs in light of explant analyses. Methods: The study focused on five explanted homemade EGs collected from 2012 to 2014. The explants were assessed in accordance with the ISO 9001/13485 certified standard protocol, which included naked eye evaluation, organic remnant cleaning, and microscopic and endoscopic examinations and analysis (magnification range from 20% to 200%). The observations report followed a classification based on 12 features assessing the fabric cover, the stitch filament, and the stents. Results: The reasons for explantation were type 1 endoleak in three cases and aneurysm sac growth in two. The implantation duration ranged from 56 to 202 months. Sixty three per cent of the fabric surface lesions (holes and tears) were related to abrasion between the fabric and the stents. Up to 33% of the knots used to connect adjacent stents were broken on one EG. Other defects including running suture rupture and stent corrosion were also observed. The overall hole cumulated surface ranged from 0.377 mm2 (56 month of implantation) up to 3.21 mm2 (78 month of implantation). Conclusion: In this study, various ageing phenomena on homemade textile EGs were identified and classified. The main damaging mechanisms were related to abrasion stress leading to tears and holes in the fabric, stitch ruptures, and detachment of stent segments responsible for serious EG deformations and further degradation.http://www.sciencedirect.com/science/article/pii/S2666688X21000344Aortic endograftsDegradationPolyesterStentTextile
spellingShingle Sheng-Heng Cao
Jennifer Canonge
Julien Gaudric
Delphine Dion
Salomé Kuntz
Jérémie Jayet
Fabien Koskas
Frédéric Heim
Anne Lejay
Nabil Chakfé
Degradation Phenomena on “Homemade” Explanted Aortic Textile Endografts
EJVES Vascular Forum
Aortic endografts
Degradation
Polyester
Stent
Textile
title Degradation Phenomena on “Homemade” Explanted Aortic Textile Endografts
title_full Degradation Phenomena on “Homemade” Explanted Aortic Textile Endografts
title_fullStr Degradation Phenomena on “Homemade” Explanted Aortic Textile Endografts
title_full_unstemmed Degradation Phenomena on “Homemade” Explanted Aortic Textile Endografts
title_short Degradation Phenomena on “Homemade” Explanted Aortic Textile Endografts
title_sort degradation phenomena on homemade explanted aortic textile endografts
topic Aortic endografts
Degradation
Polyester
Stent
Textile
url http://www.sciencedirect.com/science/article/pii/S2666688X21000344
work_keys_str_mv AT shenghengcao degradationphenomenaonhomemadeexplantedaortictextileendografts
AT jennifercanonge degradationphenomenaonhomemadeexplantedaortictextileendografts
AT juliengaudric degradationphenomenaonhomemadeexplantedaortictextileendografts
AT delphinedion degradationphenomenaonhomemadeexplantedaortictextileendografts
AT salomekuntz degradationphenomenaonhomemadeexplantedaortictextileendografts
AT jeremiejayet degradationphenomenaonhomemadeexplantedaortictextileendografts
AT fabienkoskas degradationphenomenaonhomemadeexplantedaortictextileendografts
AT fredericheim degradationphenomenaonhomemadeexplantedaortictextileendografts
AT annelejay degradationphenomenaonhomemadeexplantedaortictextileendografts
AT nabilchakfe degradationphenomenaonhomemadeexplantedaortictextileendografts