Detection of Demagnetization Faults in Axial Flux Permanent-Magnet Synchronous Wind Generators
A new method for detecting demagnetization faults in axial flux permanent magnet synchronous wind generators is presented in this study. Demagnetization faults occur in the case of total or partial loss of the magnetic properties of one or more permanent magnets of the machine. Fault signatures appe...
Main Authors: | Apostolos Lamprokostopoulos, Epameinondas Mitronikas, Alexandra Barmpatza |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2022-04-01
|
Series: | Energies |
Subjects: | |
Online Access: | https://www.mdpi.com/1996-1073/15/9/3220 |
Similar Items
-
The Neutral Voltage Difference Signal as a Means of Investigating Eccentricity and Demagnetization Faults in an AFPM Synchronous Generator
by: Alexandra C. Barmpatza
Published: (2023-06-01) -
On-Line Detection of Demagnetization for Permanent Magnet Synchronous Motor via Flux Observer
by: Liqian Cao, et al.
Published: (2022-05-01) -
Investigation of Permanent Magnet Demagnetization in Synchronous Machines during Multiple Short-Circuit Fault Conditions
by: Stefan Sjökvist, et al.
Published: (2017-10-01) -
Study of a Combined Demagnetization and Eccentricity Fault in an AFPM Synchronous Generator
by: Alexandra C. Barmpatza, et al.
Published: (2020-10-01) -
Analytical Modeling and Analysis of Permanent-Magnet Motor with Demagnetization Fault
by: Cenwei Shi, et al.
Published: (2022-12-01)