Intra and inter-rater repeatability of brachial artery ultrasound estimates of flow-mediated slowing and flow-mediated dilation.

Flow-mediated slowing (FMS) is a non-invasive measure of endothelial function measured through reactive hyperemia-induced changes in pulse wave velocity (PWV). FMS is suggested to mitigate known pitfalls of flow-mediated dilation (FMD) including suboptimal repeatability and high-operator dependency....

Full description

Bibliographic Details
Main Authors: João Luís Marôco, Tiago Silvestre, Inês Arrais, Marco Pinto, Helena Santa-Clara, Bo Fernhall, Xavier Melo
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2023-01-01
Series:PLoS ONE
Online Access:https://doi.org/10.1371/journal.pone.0287759
_version_ 1797788308339687424
author João Luís Marôco
Tiago Silvestre
Inês Arrais
Marco Pinto
Helena Santa-Clara
Bo Fernhall
Xavier Melo
author_facet João Luís Marôco
Tiago Silvestre
Inês Arrais
Marco Pinto
Helena Santa-Clara
Bo Fernhall
Xavier Melo
author_sort João Luís Marôco
collection DOAJ
description Flow-mediated slowing (FMS) is a non-invasive measure of endothelial function measured through reactive hyperemia-induced changes in pulse wave velocity (PWV). FMS is suggested to mitigate known pitfalls of flow-mediated dilation (FMD) including suboptimal repeatability and high-operator dependency. However, the few single-rater studies that examined FMS repeatability have shown controversial results and used only regional measurements of PWV, which might not reflect local brachial artery stiffness responses to reactive hyperemia. We assessed the inter- and intra-rater repeatability of ultrasound-based changes in local PWV (FMS) and diameter (FMD). Twenty-four healthy male participants aged 23-75 yr, were examined on two separate days. Reactive hyperemia-induced changes in PWV were calculated using a tailored R-script. The inter- and intra-rater repeatability were tested with the intraclass correlation coefficient (ICC), coefficient of variation (CV), and the Bland-Altman plot estimates. The inter-rater repeatability of FMS (bias: -0.08%; ICC: 0.85; 95% CI: 0.65 to 0.93; CV: 11%) and FMD (bias: -0.02%; ICC: 0.98; 95% CI: 0.97 to 0.99; CV: 7%) showed overall good repeatability over different days. The intra-rater repeatability of FMD (1st rater: bias: 0.27%; ICC: 0.90; 95% CI: 0.78 to 0.96; CV: 14%; 2nd rater: bias: 0.60%; ICC: 0.85; 95% CI: 0.64 to 0.94; CV: 18%) was better than FMS (1st rater: bias: -1.03%; ICC: 0.76; 95% CI: 0.44 to 0.91; CV: 21%; 2nd rater: bias:-0.49%; ICC: 0.70; 95% CI: 0.34 to 0.80; CV: 23%) but not different between raters. Ultrasound-based local measurements of PWV deceleration reactive hyperemia were repeatable among the raters.
first_indexed 2024-03-13T01:33:44Z
format Article
id doaj.art-3cb659cf01944ecdb36d0cbae55062a7
institution Directory Open Access Journal
issn 1932-6203
language English
last_indexed 2024-03-13T01:33:44Z
publishDate 2023-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj.art-3cb659cf01944ecdb36d0cbae55062a72023-07-04T05:32:00ZengPublic Library of Science (PLoS)PLoS ONE1932-62032023-01-01186e028775910.1371/journal.pone.0287759Intra and inter-rater repeatability of brachial artery ultrasound estimates of flow-mediated slowing and flow-mediated dilation.João Luís MarôcoTiago SilvestreInês ArraisMarco PintoHelena Santa-ClaraBo FernhallXavier MeloFlow-mediated slowing (FMS) is a non-invasive measure of endothelial function measured through reactive hyperemia-induced changes in pulse wave velocity (PWV). FMS is suggested to mitigate known pitfalls of flow-mediated dilation (FMD) including suboptimal repeatability and high-operator dependency. However, the few single-rater studies that examined FMS repeatability have shown controversial results and used only regional measurements of PWV, which might not reflect local brachial artery stiffness responses to reactive hyperemia. We assessed the inter- and intra-rater repeatability of ultrasound-based changes in local PWV (FMS) and diameter (FMD). Twenty-four healthy male participants aged 23-75 yr, were examined on two separate days. Reactive hyperemia-induced changes in PWV were calculated using a tailored R-script. The inter- and intra-rater repeatability were tested with the intraclass correlation coefficient (ICC), coefficient of variation (CV), and the Bland-Altman plot estimates. The inter-rater repeatability of FMS (bias: -0.08%; ICC: 0.85; 95% CI: 0.65 to 0.93; CV: 11%) and FMD (bias: -0.02%; ICC: 0.98; 95% CI: 0.97 to 0.99; CV: 7%) showed overall good repeatability over different days. The intra-rater repeatability of FMD (1st rater: bias: 0.27%; ICC: 0.90; 95% CI: 0.78 to 0.96; CV: 14%; 2nd rater: bias: 0.60%; ICC: 0.85; 95% CI: 0.64 to 0.94; CV: 18%) was better than FMS (1st rater: bias: -1.03%; ICC: 0.76; 95% CI: 0.44 to 0.91; CV: 21%; 2nd rater: bias:-0.49%; ICC: 0.70; 95% CI: 0.34 to 0.80; CV: 23%) but not different between raters. Ultrasound-based local measurements of PWV deceleration reactive hyperemia were repeatable among the raters.https://doi.org/10.1371/journal.pone.0287759
spellingShingle João Luís Marôco
Tiago Silvestre
Inês Arrais
Marco Pinto
Helena Santa-Clara
Bo Fernhall
Xavier Melo
Intra and inter-rater repeatability of brachial artery ultrasound estimates of flow-mediated slowing and flow-mediated dilation.
PLoS ONE
title Intra and inter-rater repeatability of brachial artery ultrasound estimates of flow-mediated slowing and flow-mediated dilation.
title_full Intra and inter-rater repeatability of brachial artery ultrasound estimates of flow-mediated slowing and flow-mediated dilation.
title_fullStr Intra and inter-rater repeatability of brachial artery ultrasound estimates of flow-mediated slowing and flow-mediated dilation.
title_full_unstemmed Intra and inter-rater repeatability of brachial artery ultrasound estimates of flow-mediated slowing and flow-mediated dilation.
title_short Intra and inter-rater repeatability of brachial artery ultrasound estimates of flow-mediated slowing and flow-mediated dilation.
title_sort intra and inter rater repeatability of brachial artery ultrasound estimates of flow mediated slowing and flow mediated dilation
url https://doi.org/10.1371/journal.pone.0287759
work_keys_str_mv AT joaoluismaroco intraandinterraterrepeatabilityofbrachialarteryultrasoundestimatesofflowmediatedslowingandflowmediateddilation
AT tiagosilvestre intraandinterraterrepeatabilityofbrachialarteryultrasoundestimatesofflowmediatedslowingandflowmediateddilation
AT inesarrais intraandinterraterrepeatabilityofbrachialarteryultrasoundestimatesofflowmediatedslowingandflowmediateddilation
AT marcopinto intraandinterraterrepeatabilityofbrachialarteryultrasoundestimatesofflowmediatedslowingandflowmediateddilation
AT helenasantaclara intraandinterraterrepeatabilityofbrachialarteryultrasoundestimatesofflowmediatedslowingandflowmediateddilation
AT bofernhall intraandinterraterrepeatabilityofbrachialarteryultrasoundestimatesofflowmediatedslowingandflowmediateddilation
AT xaviermelo intraandinterraterrepeatabilityofbrachialarteryultrasoundestimatesofflowmediatedslowingandflowmediateddilation