Experimental Analysis of Surface Application of Fiber-Reinforced Polymer Composite on Shear Behavior of Masonry Walls Made of Autoclaved Concrete Blocks

This paper presents the results of an experimental study of the shear behavior of masonry walls made of aero autoclaved concrete (AAC) blocks strengthened by externally bonded fiber-reinforced polymer (FRP) composites. Fifteen small wall specimens were constructed and tested in a diagonal compressio...

Full description

Bibliographic Details
Main Author: Marta Kałuża
Format: Article
Language:English
Published: MDPI AG 2022-12-01
Series:Buildings
Subjects:
Online Access:https://www.mdpi.com/2075-5309/12/12/2208
_version_ 1797461070223245312
author Marta Kałuża
author_facet Marta Kałuża
author_sort Marta Kałuża
collection DOAJ
description This paper presents the results of an experimental study of the shear behavior of masonry walls made of aero autoclaved concrete (AAC) blocks strengthened by externally bonded fiber-reinforced polymer (FRP) composites. Fifteen small wall specimens were constructed and tested in a diagonal compression scheme. Two types of composite materials—carbon- and glass-reinforced polymers—were arranged in two configurations of vertical strips, adopted to the location of the unfilled head joints. The effect of the strengthening location and strengthening materials on changes in the strength and deformability parameters are discussed and the failure process of unstrengthened walls is also presented. The placement of the composite on unfilled head joints proved to be a better solution. Carbon-fiber-reinforced polymer (CFRP) strips provided a threefold increase in stiffness, a 48% increase in load-bearing capacity and a high level of ductility in the post-cracking phase. Glass-fiber-reinforced polymer (GFRP) strips offered a 56% increase in load-bearing capacity but did not change the stiffness of the masonry and provided relatively little ductility. Placing the composite between unfilled joints was only reasonable for CFRP composites, providing a 35% increase in load-bearing capacity but with negligible ductility of the masonry.
first_indexed 2024-03-09T17:15:06Z
format Article
id doaj.art-3cc7122c501d4ff2aabccc63b6fc99ad
institution Directory Open Access Journal
issn 2075-5309
language English
last_indexed 2024-03-09T17:15:06Z
publishDate 2022-12-01
publisher MDPI AG
record_format Article
series Buildings
spelling doaj.art-3cc7122c501d4ff2aabccc63b6fc99ad2023-11-24T13:43:39ZengMDPI AGBuildings2075-53092022-12-011212220810.3390/buildings12122208Experimental Analysis of Surface Application of Fiber-Reinforced Polymer Composite on Shear Behavior of Masonry Walls Made of Autoclaved Concrete BlocksMarta Kałuża0Department of Civil Engineering, Silesian University of Technology, Akademicka 5 St., 44-100 Gliwice, PolandThis paper presents the results of an experimental study of the shear behavior of masonry walls made of aero autoclaved concrete (AAC) blocks strengthened by externally bonded fiber-reinforced polymer (FRP) composites. Fifteen small wall specimens were constructed and tested in a diagonal compression scheme. Two types of composite materials—carbon- and glass-reinforced polymers—were arranged in two configurations of vertical strips, adopted to the location of the unfilled head joints. The effect of the strengthening location and strengthening materials on changes in the strength and deformability parameters are discussed and the failure process of unstrengthened walls is also presented. The placement of the composite on unfilled head joints proved to be a better solution. Carbon-fiber-reinforced polymer (CFRP) strips provided a threefold increase in stiffness, a 48% increase in load-bearing capacity and a high level of ductility in the post-cracking phase. Glass-fiber-reinforced polymer (GFRP) strips offered a 56% increase in load-bearing capacity but did not change the stiffness of the masonry and provided relatively little ductility. Placing the composite between unfilled joints was only reasonable for CFRP composites, providing a 35% increase in load-bearing capacity but with negligible ductility of the masonry.https://www.mdpi.com/2075-5309/12/12/2208AAC blocksFRP strengtheningshear behaviormasonry wallsdiagonal compression
spellingShingle Marta Kałuża
Experimental Analysis of Surface Application of Fiber-Reinforced Polymer Composite on Shear Behavior of Masonry Walls Made of Autoclaved Concrete Blocks
Buildings
AAC blocks
FRP strengthening
shear behavior
masonry walls
diagonal compression
title Experimental Analysis of Surface Application of Fiber-Reinforced Polymer Composite on Shear Behavior of Masonry Walls Made of Autoclaved Concrete Blocks
title_full Experimental Analysis of Surface Application of Fiber-Reinforced Polymer Composite on Shear Behavior of Masonry Walls Made of Autoclaved Concrete Blocks
title_fullStr Experimental Analysis of Surface Application of Fiber-Reinforced Polymer Composite on Shear Behavior of Masonry Walls Made of Autoclaved Concrete Blocks
title_full_unstemmed Experimental Analysis of Surface Application of Fiber-Reinforced Polymer Composite on Shear Behavior of Masonry Walls Made of Autoclaved Concrete Blocks
title_short Experimental Analysis of Surface Application of Fiber-Reinforced Polymer Composite on Shear Behavior of Masonry Walls Made of Autoclaved Concrete Blocks
title_sort experimental analysis of surface application of fiber reinforced polymer composite on shear behavior of masonry walls made of autoclaved concrete blocks
topic AAC blocks
FRP strengthening
shear behavior
masonry walls
diagonal compression
url https://www.mdpi.com/2075-5309/12/12/2208
work_keys_str_mv AT martakałuza experimentalanalysisofsurfaceapplicationoffiberreinforcedpolymercompositeonshearbehaviorofmasonrywallsmadeofautoclavedconcreteblocks