Electrolytes Levels (Na, K, Cl) in Serum Stored at 4°C Temperature

The samples used for serum electrolyte measurement should be analyzed immediately after being received in the laboratory within 1-2 hours to avoid an increase in the error of the results. Serum should be stored at 4°C for a period to prevent damage. The analyst should consider maximum delay time in...

Full description

Bibliographic Details
Main Authors: Amalia Nurul Fauziah, M. Atik Martsiningsih, Budi Setiawan
Format: Article
Language:English
Published: Universitas Nahdlatul Ulama Surabaya 2021-10-01
Series:Indonesian Journal of Medical Laboratory Science and Technology
Subjects:
Online Access:https://journal2.unusa.ac.id/index.php/IJMLST/article/view/1870
_version_ 1811254106420936704
author Amalia Nurul Fauziah
M. Atik Martsiningsih
Budi Setiawan
author_facet Amalia Nurul Fauziah
M. Atik Martsiningsih
Budi Setiawan
author_sort Amalia Nurul Fauziah
collection DOAJ
description The samples used for serum electrolyte measurement should be analyzed immediately after being received in the laboratory within 1-2 hours to avoid an increase in the error of the results. Serum should be stored at 4°C for a period to prevent damage. The analyst should consider maximum delay time in the examination to maintain the serum's quality. This study compared the 2-hour and 3-hour delays in sodium (Na), potassium (K), and chlorine (Cl) tests. The method used in this study is an observational analysis with a cross-sectional study design. The samples in this study used 35 patient serum residues. The study was conducted in November 2020 with a continuous sampling technique. Electrolyte levels in the sample were measured by AVL 9180 Electrolyte Analyzer using Ion-Selective Electrode (ISE) method. The differences in electrolyte (Na, K, Cl) levels were analyzed by the Kruskal-Wallis Statistical test at a 95% confidence level. The results showed that the content of sodium, potassium, and chlorine were 0.719; 0.976; and 0.772. This study showed that there was no significant difference in the electrolyte content of sodium (Na), potassium (K), and chlorine (Cl) in the serum directly detected from the serum stored at 4°C for 2 hours and 3 hours. In conclusion, it is acceptable to postpone the serum test for 3 hours with various considerations.
first_indexed 2024-04-12T17:02:14Z
format Article
id doaj.art-3cea35f9e2a34739ae17bba51d7758aa
institution Directory Open Access Journal
issn 2684-6748
2656-9825
language English
last_indexed 2024-04-12T17:02:14Z
publishDate 2021-10-01
publisher Universitas Nahdlatul Ulama Surabaya
record_format Article
series Indonesian Journal of Medical Laboratory Science and Technology
spelling doaj.art-3cea35f9e2a34739ae17bba51d7758aa2022-12-22T03:24:03ZengUniversitas Nahdlatul Ulama SurabayaIndonesian Journal of Medical Laboratory Science and Technology2684-67482656-98252021-10-013210.33086/ijmlst.v3i2.1870Electrolytes Levels (Na, K, Cl) in Serum Stored at 4°C TemperatureAmalia Nurul Fauziah0M. Atik Martsiningsih1Budi Setiawan2Pratama Hospital Yogyakarta, Yogyakarta City, Yogyakarta, IndonesiaD-III of Medical Laboratory Technology, Poltekkes Kemenkes Yogyakarta, Yogyakarta, IndonesiaBachelor’s Degrees in Medical Laboratory Technology, Poltekkes Kemenkes Yogyakarta, Yogyakarta, Indonesia The samples used for serum electrolyte measurement should be analyzed immediately after being received in the laboratory within 1-2 hours to avoid an increase in the error of the results. Serum should be stored at 4°C for a period to prevent damage. The analyst should consider maximum delay time in the examination to maintain the serum's quality. This study compared the 2-hour and 3-hour delays in sodium (Na), potassium (K), and chlorine (Cl) tests. The method used in this study is an observational analysis with a cross-sectional study design. The samples in this study used 35 patient serum residues. The study was conducted in November 2020 with a continuous sampling technique. Electrolyte levels in the sample were measured by AVL 9180 Electrolyte Analyzer using Ion-Selective Electrode (ISE) method. The differences in electrolyte (Na, K, Cl) levels were analyzed by the Kruskal-Wallis Statistical test at a 95% confidence level. The results showed that the content of sodium, potassium, and chlorine were 0.719; 0.976; and 0.772. This study showed that there was no significant difference in the electrolyte content of sodium (Na), potassium (K), and chlorine (Cl) in the serum directly detected from the serum stored at 4°C for 2 hours and 3 hours. In conclusion, it is acceptable to postpone the serum test for 3 hours with various considerations. https://journal2.unusa.ac.id/index.php/IJMLST/article/view/1870ChlorideDelay TimePotassiumSerumSodium
spellingShingle Amalia Nurul Fauziah
M. Atik Martsiningsih
Budi Setiawan
Electrolytes Levels (Na, K, Cl) in Serum Stored at 4°C Temperature
Indonesian Journal of Medical Laboratory Science and Technology
Chloride
Delay Time
Potassium
Serum
Sodium
title Electrolytes Levels (Na, K, Cl) in Serum Stored at 4°C Temperature
title_full Electrolytes Levels (Na, K, Cl) in Serum Stored at 4°C Temperature
title_fullStr Electrolytes Levels (Na, K, Cl) in Serum Stored at 4°C Temperature
title_full_unstemmed Electrolytes Levels (Na, K, Cl) in Serum Stored at 4°C Temperature
title_short Electrolytes Levels (Na, K, Cl) in Serum Stored at 4°C Temperature
title_sort electrolytes levels na k cl in serum stored at 4°c temperature
topic Chloride
Delay Time
Potassium
Serum
Sodium
url https://journal2.unusa.ac.id/index.php/IJMLST/article/view/1870
work_keys_str_mv AT amalianurulfauziah electrolyteslevelsnakclinserumstoredat4ctemperature
AT matikmartsiningsih electrolyteslevelsnakclinserumstoredat4ctemperature
AT budisetiawan electrolyteslevelsnakclinserumstoredat4ctemperature