Ozone measurements in Zagreb, Croatia, at the end of 19th century compared to the present data

Surface ozone measurements at the Zagreb-Grič Meteorological Observatory (founded in 1861), applying the Schönbein colorimetric method, were introduced at the end of the 19th century (1889-1900), at the time of the city's most intensive development. The data measured in 11 (0-10) grade Schönbei...

Full description

Bibliographic Details
Main Authors: Inga Lisac, Vladis Vujnović, Antun Marki
Format: Article
Language:English
Published: Borntraeger 2010-04-01
Series:Meteorologische Zeitschrift
Online Access:http://dx.doi.org/10.1127/0941-2948/2010/0432
_version_ 1797332560691331072
author Inga Lisac
Vladis Vujnović
Antun Marki
author_facet Inga Lisac
Vladis Vujnović
Antun Marki
author_sort Inga Lisac
collection DOAJ
description Surface ozone measurements at the Zagreb-Grič Meteorological Observatory (founded in 1861), applying the Schönbein colorimetric method, were introduced at the end of the 19th century (1889-1900), at the time of the city's most intensive development. The data measured in 11 (0-10) grade Schönbein scale were published in the Observatory annual journals. The well-known geophysicist, Andrija Mohorovičić, then a leader of the Observatory, supervised the surface ozone measurements. The ozone data, converted into quantitative units (ppb (the symbol ppb in the text relates to volume ratios (ppbv), which differ from mass ratios (ppbm), but as only volume ratios are used in the article, the simple unit symbol ppb is used.) after applying several statistical tests for the data quality check, were compared with recent ozone data. These first results, including the conversion method used, were published. In our study some additional quality data tests and ozone data comparisons were made, and a description of significant environmental conditions surrounding the measuring site in Zagreb was presented. A comparison between the multiannual data from the pre-industrial period and the ones from the recent multiannual period was made, based on annual and monthly averages. The average value of the surface ozone at the end of the 20th century (1989-1994) in Zagreb is by 24 % higher compared to the end of the 19th century. The rise relates to daily maxima in both time series. A bi-modal shape of the annual run of the surface ozone monthly average was found in the older as well as in the more recent data sets. The position of the primary maximum in the cold part of the year (winter/spring) during the last decade of the 19th century points at the rural surface-air characteristics. The annual primary maximum during the recent observation period was found in the summer months, and it demonstrates an increase in air pollution, mostly of anthropogenic origin. The old Zagreb pre-industrial ozone data show the expected sensitivity to the basic climatic factors, daily and annually.
first_indexed 2024-03-08T07:51:39Z
format Article
id doaj.art-3d2792d49d884163ba2ba00e62e5e63c
institution Directory Open Access Journal
issn 0941-2948
language English
last_indexed 2024-03-08T07:51:39Z
publishDate 2010-04-01
publisher Borntraeger
record_format Article
series Meteorologische Zeitschrift
spelling doaj.art-3d2792d49d884163ba2ba00e62e5e63c2024-02-02T14:44:21ZengBorntraegerMeteorologische Zeitschrift0941-29482010-04-0119216917810.1127/0941-2948/2010/043274935Ozone measurements in Zagreb, Croatia, at the end of 19th century compared to the present dataInga LisacVladis VujnovićAntun MarkiSurface ozone measurements at the Zagreb-Grič Meteorological Observatory (founded in 1861), applying the Schönbein colorimetric method, were introduced at the end of the 19th century (1889-1900), at the time of the city's most intensive development. The data measured in 11 (0-10) grade Schönbein scale were published in the Observatory annual journals. The well-known geophysicist, Andrija Mohorovičić, then a leader of the Observatory, supervised the surface ozone measurements. The ozone data, converted into quantitative units (ppb (the symbol ppb in the text relates to volume ratios (ppbv), which differ from mass ratios (ppbm), but as only volume ratios are used in the article, the simple unit symbol ppb is used.) after applying several statistical tests for the data quality check, were compared with recent ozone data. These first results, including the conversion method used, were published. In our study some additional quality data tests and ozone data comparisons were made, and a description of significant environmental conditions surrounding the measuring site in Zagreb was presented. A comparison between the multiannual data from the pre-industrial period and the ones from the recent multiannual period was made, based on annual and monthly averages. The average value of the surface ozone at the end of the 20th century (1989-1994) in Zagreb is by 24 % higher compared to the end of the 19th century. The rise relates to daily maxima in both time series. A bi-modal shape of the annual run of the surface ozone monthly average was found in the older as well as in the more recent data sets. The position of the primary maximum in the cold part of the year (winter/spring) during the last decade of the 19th century points at the rural surface-air characteristics. The annual primary maximum during the recent observation period was found in the summer months, and it demonstrates an increase in air pollution, mostly of anthropogenic origin. The old Zagreb pre-industrial ozone data show the expected sensitivity to the basic climatic factors, daily and annually.http://dx.doi.org/10.1127/0941-2948/2010/0432
spellingShingle Inga Lisac
Vladis Vujnović
Antun Marki
Ozone measurements in Zagreb, Croatia, at the end of 19th century compared to the present data
Meteorologische Zeitschrift
title Ozone measurements in Zagreb, Croatia, at the end of 19th century compared to the present data
title_full Ozone measurements in Zagreb, Croatia, at the end of 19th century compared to the present data
title_fullStr Ozone measurements in Zagreb, Croatia, at the end of 19th century compared to the present data
title_full_unstemmed Ozone measurements in Zagreb, Croatia, at the end of 19th century compared to the present data
title_short Ozone measurements in Zagreb, Croatia, at the end of 19th century compared to the present data
title_sort ozone measurements in zagreb croatia at the end of 19th century compared to the present data
url http://dx.doi.org/10.1127/0941-2948/2010/0432
work_keys_str_mv AT ingalisac ozonemeasurementsinzagrebcroatiaattheendof19thcenturycomparedtothepresentdata
AT vladisvujnovic ozonemeasurementsinzagrebcroatiaattheendof19thcenturycomparedtothepresentdata
AT antunmarki ozonemeasurementsinzagrebcroatiaattheendof19thcenturycomparedtothepresentdata