Study on insulation effect of hollow riser
According to the air insulation, the use of riser hollow way to reduce the riser heat transfer, improve the riser insulation effect. In the experimental simulation, the corundum brick inner and outer wall and the air gap temperature were measured. The optimal air gap is 25 mm from the heat transfer...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Croatian Metallurgical Society
2018-01-01
|
Series: | Metalurgija |
Subjects: | |
Online Access: | http://hrcak.srce.hr/file/293315 |
_version_ | 1818509874509643776 |
---|---|
author | Y. J. Liu M. G. Shen Z. Q. Lv X. H. Han |
author_facet | Y. J. Liu M. G. Shen Z. Q. Lv X. H. Han |
author_sort | Y. J. Liu |
collection | DOAJ |
description | According to the air insulation, the use of riser hollow way to reduce the riser heat transfer, improve the riser insulation effect. In the experimental simulation, the corundum brick inner and outer wall and the air gap temperature were measured. The optimal air gap is 25 mm from the heat transfer theory and the outer wall temperature, but the insula- tion effect is not obvious. To further explore, proposed in the inner and outer walls to 25 mm as a unit into the insula- tion board improvement measures. The results show that the insertion of the insulation board can greatly reduce the temperature of the outer wall and improve the insulation effect. When inserting a heat shield, the heat flow can be reduced by about 50 %. With the increase in the number of inserts inserted, the insulation effect is gradually increased. |
first_indexed | 2024-12-10T22:51:23Z |
format | Article |
id | doaj.art-3d378f8fb72444e29ecc628abdd15f22 |
institution | Directory Open Access Journal |
issn | 0543-5846 1334-2576 |
language | English |
last_indexed | 2024-12-10T22:51:23Z |
publishDate | 2018-01-01 |
publisher | Croatian Metallurgical Society |
record_format | Article |
series | Metalurgija |
spelling | doaj.art-3d378f8fb72444e29ecc628abdd15f222022-12-22T01:30:23ZengCroatian Metallurgical SocietyMetalurgija0543-58461334-25762018-01-01573146148Study on insulation effect of hollow riserY. J. Liu0M. G. Shen1Z. Q. Lv2X. H. Han3College of Materials and Metallurgy, University of Science and Technology Liaoning, Anshan City, ChinaCollege of Materials and Metallurgy, University of Science and Technology Liaoning, Anshan City, ChinaCollege of Materials and Metallurgy, University of Science and Technology Liaoning, Anshan City, ChinaCollege of Materials and Metallurgy, University of Science and Technology Liaoning, Anshan City, ChinaAccording to the air insulation, the use of riser hollow way to reduce the riser heat transfer, improve the riser insulation effect. In the experimental simulation, the corundum brick inner and outer wall and the air gap temperature were measured. The optimal air gap is 25 mm from the heat transfer theory and the outer wall temperature, but the insula- tion effect is not obvious. To further explore, proposed in the inner and outer walls to 25 mm as a unit into the insula- tion board improvement measures. The results show that the insertion of the insulation board can greatly reduce the temperature of the outer wall and improve the insulation effect. When inserting a heat shield, the heat flow can be reduced by about 50 %. With the increase in the number of inserts inserted, the insulation effect is gradually increased.http://hrcak.srce.hr/file/293315castingheat transferhollowinsulationtemperature |
spellingShingle | Y. J. Liu M. G. Shen Z. Q. Lv X. H. Han Study on insulation effect of hollow riser Metalurgija casting heat transfer hollow insulation temperature |
title | Study on insulation effect of hollow riser |
title_full | Study on insulation effect of hollow riser |
title_fullStr | Study on insulation effect of hollow riser |
title_full_unstemmed | Study on insulation effect of hollow riser |
title_short | Study on insulation effect of hollow riser |
title_sort | study on insulation effect of hollow riser |
topic | casting heat transfer hollow insulation temperature |
url | http://hrcak.srce.hr/file/293315 |
work_keys_str_mv | AT yjliu studyoninsulationeffectofhollowriser AT mgshen studyoninsulationeffectofhollowriser AT zqlv studyoninsulationeffectofhollowriser AT xhhan studyoninsulationeffectofhollowriser |